VIP member
Electric heating magnetic flap level gauge
This page is an introduction page about electric heating magnetic flap level gauge selected by Jiangsu Meiante for users. It can also be called electr
Product details
The electric heat tracing magnetic flap level gauge and insulation type magnetic flap level gauge produced by our company are installed with an electric mixing heat source and asbestos insulation layer outside the main body of the base type, which can maintain the temperature of the liquid inside the main body at around 75 ℃ to ensure normal liquid flow. The outer side is made of 304 stainless steel plate with a beautiful appearance. Electric heat tracing heating magnetic flap level gauge is suitable for liquids that solidify in low-temperature environments
Electric heat tracingelectrical heatingMain parameters of magnetic flap level gauge
Measurement range: 500~8000mm
Accuracy: ± 10mm (insulation type)
Work pressure: ≤ 2.5MPa (ordinary type)
≤ 10.0MPa (high pressure type)
≤ 2.5MPa (anti-corrosion type)
Measurement range: 500~8000mm
Accuracy: ± 10mm (insulation type)
Work pressure: ≤ 2.5MPa (ordinary type)
≤ 10.0MPa (high pressure type)
≤ 2.5MPa (anti-corrosion type)
Environmental temperature -40 ℃ -50 ℃
Insulation type magnetic flap level gauge medium density: 0.45~2g/cm3
● Medium density difference: ≥ 0.15g/cm3 (measurement boundary)
● Medium temperature: -80 ℃~+450 ℃
Insulation type magnetic flap level gauge medium density: 0.45~2g/cm3
● Medium density difference: ≥ 0.15g/cm3 (measurement boundary)
● Medium temperature: -80 ℃~+450 ℃
Power: 25 w/m, 35 w/m High maintenance temperature: 65 ℃
Medium viscosity: ≤ 0.4 Pa · s. For media with high viscosity or media that are prone to crystallization at low temperatures, a heating jacket type liquid level gauge can be selected according to user requirements.
Environmental vibration: frequency ≤ 25HZ, amplitude ≤ 0.5mm
Interface flange: Adopting the HG20592~20635-97 flange standard newly issued by the Ministry of Chemical Industry in 1997.
If users need to adopt other standards (such as GB, ANSI, DIN, etc.), they can design according to their needs.
Medium viscosity: ≤ 0.4 Pa · s. For media with high viscosity or media that are prone to crystallization at low temperatures, a heating jacket type liquid level gauge can be selected according to user requirements.
Environmental vibration: frequency ≤ 25HZ, amplitude ≤ 0.5mm
Interface flange: Adopting the HG20592~20635-97 flange standard newly issued by the Ministry of Chemical Industry in 1997.
If users need to adopt other standards (such as GB, ANSI, DIN, etc.), they can design according to their needs.
Online inquiry