¥Product Introduction
The EV510H series high-performance current vector frequency converter has the characteristics of small size, light weight, and easy portability, making it a functionally enhanced product. Can be used as a driver for textile, papermaking, wire drawing, machine tools, packaging, food, fans, water pumps, and various automated production equipment.
-
¥Product Features
project
specification
base
this
merit
can
Highest frequency
Vector control:0~500HzTheV/Fcontrol: 0~500Hz
carrier frequency
0.8kHz~12kHz The carrier frequency can be automatically adjusted according to the load characteristics.
Input frequency resolution
Number setting:0.01Hz 、Simulation setting: maximum frequency×0.025%
Control method
Open-loop vector control(SVC)、Closed-loop vector control(FVC)TheV/Fcontrol
Starting torque
GType machine:0.5Hz/150%(SVC)The0Hz/180%(FVC);PType machine:0.5Hz/100%
speed regulation range
1:100 (SVC)
1:1000 (FVC)
Steady speed accuracy
±0.5%(SVC)
±0.02%(FVC)
Torque control accuracy
±5%(FVC)
overload capacity
GType machine:150%rated current60s、180%rated current3s;
PType machine:120%rated current60s、150%rated current3s
torque boost
Automatic torque boost; Manual torque increase0.1%~30.0%
V/Fcurve
Three ways: straight line type、Multi-point typeTheNQuadratic typeV/Fcurve
(1.2The second party1.4The second party1.6The second party1.8The second party2The second party)
Acceleration and deceleration curve
Straight line orSCurve acceleration and deceleration method. Four types of acceleration and deceleration times, acceleration and deceleration time range0.0~6500.0s
DC braking
DC braking frequency:0.00Hz~maximum frequency、Braking time:0.0s~36.0sbraking、Action current value:0.0%~100.0%
Jog control
Jogging frequency range:0.00Hz~50.00Hz、Jogging acceleration and deceleration time0.0s~6500.0s.
simplePLCMulti speed operation
Through built-inPLCOr control the terminal to achieve the maximum16Segment speed operation
built-inPID
Convenient implementation of process control closed-loop control system
Automatic voltage adjustment(AVR)
When the voltage of the power grid changes, it can automatically maintain a constant output voltage
Overvoltage, overcurrent, and stall control
Automatic limitation of current and voltage during operation to prevent frequent overcurrent and overvoltage tripping
Quick current limiting function
Minimize overcurrent faults to protect the normal operation of the frequency converter
Torque Limitation and Control
Excavator”Features: automatic torque limitation during operation to prevent frequent overcurrent tripping; Closed loop vector mode can achieve torque control
a
sex
transform
merit
can
Excellent performance
Using high-performance current vector control technologyenhanceasynchronous motorperformance
Instantly stop without stopping
During an instantaneous power outage, compensating for the decrease in voltage through load feedback energy is used to maintain the operation of the frequency converter for a short period of time
Fast current limiting
Avoid frequent overcurrent faults in the frequency converter
Timer control function
Timer control function: Set time range0.0Min~6500.0Min
Command source
Set the operation panel, control terminal, and serial communication port. Can be switched in multiple ways
frequency source/Auxiliary frequency source
Digital given, analog voltage given, analog current given, pulse given, serial port given. Can be switched in multiple ways
transport
line
input terminal
5Number input terminals, among which1The highest support100kHzHigh speed pulse input(Optional);
2An analog input terminal;AI2support0~10VVoltage input;AI1support0~10VVoltage input or0~20mAcurrent input
output terminal
1A high-speed pulse output terminal (optional open collector type), supporting0~100kHzSquare wave signal output(Optional);1A relay output terminal;1An analog output terminal that supports0~20mAcurrent output
apparent
show
and
key
plate
LEDdisplay
display parameters
Key locking and function selection
Implement partial or complete locking of keys, define the scope of action of some keys to prevent accidental operation
protection function
Short circuit detection of power on motor, output phase loss protection, overcurrent protection, overvoltage protection, undervoltage protection
Overheating protection, overload protection, etc
ring
realm
Usage location
Indoor, not exposed to direct sunlight, free from dust, corrosive gases, flammable gases, oil mist, water vapor, dripping or salt, etc
altitude
below1000m, higher than1000mReduce usage, every increase100mThe rated output current decreases1%
ambient temperature
-10℃~+40℃The ambient temperature is40℃~50℃Please reduce the usage amount
humidity
less than95%RHNo condensation of water droplets
LCD control panel
LCDDisplay and operate the keyboard; Parameter copying(Optional)
-
¥Technical Specifications
Frequency converter model
power capacityKVA
input currentA
output currentA
Adapted motorKW
Single phase power supply:220V,50/60Hz
EV510H-0004G-S2
1.0
5.4
2.3
0.4
EV510H-0007G-S2
1.5
8.2
4.0
0.75
EV510H-0015G-S2
3.0
14.0
7.0
1.5
EV510H-0022G-S2
4.0
23.0
9.6
2.2
Three phase power supply:380V,50/60Hz
EV510H-0007G-T4
1.5
3.4
2.1
0.75
EV510H-0015G-T4
3.0
5.0
3.8
1.5
EV510H-0022G-T4
4.0
5.8
5.1
2.2
EV510H-0037G/0055P-T4
5.9
10.5
9.0
3.7
EV510H-0055G/0075P-T4
8.9
14.6
13.0
5.5
-
¥Overall dimensions
¥mechanical parameters
Specification Model
External dimensions(mm)
installation aperture
B
W
H
D
EV510H-0004G-S2
155
84
170
127
F5.7
EV510H-0007G-S2
EV510H-0015G-S2
EV510H-0022G-S2
EV510H-0007G-T4
EV510H-0015G-T4
EV510H-0022G-T4
EV510H-0037G/0055P-T4
183
91
193
142
F4.7
EV510H-0055G/0075P-T4
¥External dimensions of the operation panel