The EJA430A absolute pressure transmitter can be used to measure the pressure of liquids, gases, or vapors, and then convert it into a 4-20mA DC current signal output. The EJA series supports BRANHART and FOUNDATION ™ Fieldbus or PROFIBSUS PA communication protocol.
|
EJA430A pressure transmitter |
A membrane box |
B membrane box |
measuring range |
-0.1~3MPa (-15~430psi) |
-0.1~14MPa (-15~2000psi) |
Measurement range |
0.03~3MPa (4.3~430psi) |
0.14~14MPa (20~2000psi) |
accuracy |
±0.065% |
±0.065% |
protection grade |
IP67,NEMA 4X, And JIS C0920 immersion proof type |
Explosion proof specifications |
FM,CENELEC ATEX,CSA,IECEx |
output signal |
4~20mA DC or FOUNDATION ™ Fieldbus or PROFIBUS PA two-wire digital communication |
power supply |
BRAN and HART: 10.5~42V DC (intrinsic safety type: 10.5~30V DC) Fieldbus: 9~32V DC (Intrinsic Safety Entity Mode 9~24V DC, Intrinsic Safety FISCO Mode 9~17.5V DC) |
ambient temperature |
-40-85 ℃ (-40~185 ℉) (ordinary type) -30~80 ℃ (-22~176 ℉) (with built-in indicator) |
process temperature |
-40-120 ℃ (-40~248 ℉) (ordinary type) |
Maximum overvoltage |
4.5MPa (645psig) |
21MPa (3000psig) |
install |
2-inch pipe installation |
Material of liquid receiving components |
Capsule |
SUS316L (diaphragm: Hastelloy C-276), Hastelloy C-276, tantalum material, Monel |
Container flange |
SUS316, Hastelloy C-276, Monel |
casing |
Aluminum alloy or SUS316 stainless steel (optional) |
EJA430A - Selection Table
Basic specification code: EJA430A-DAS5A-92NN
Item 1: Output signal |
-D |
4-20mA DC/with digital communication (BRAN protocol) |
-E |
4-20mA DC/with digital communication (HART protocol) |
-F |
FF fieldbus communication |
|
Item 2: Measurement range (membrane box) |
|
Item 3: Material of liquid receiving parts |
S |
JIS SCS14A JIS SUS316L JIS SUS316 |
H |
JIS SCS14A Hastelloy C-276 JIS SUS316 |
M |
JIS SCS14A Monel JIS SUS316 |
T |
JIS SCS14A Tantalum JIS SUS316 |
A |
Hastelloy C-276 Hastelloy C-276 Hastelloy C-276 |
D |
Hastelloy C-276 Tantalum Hastelloy C-276 |
B |
Monel Monel Monel Monel |
|
Item 4: Process Interface |
0
|
No process joint (RC1/4 internal thread on chamber flange) |
1
|
RC1/4 internal thread process joint |
2
|
RC1/2 internal thread process joint |
3
|
1/4NPT internal thread process joint |
4
|
1/2NPT internal thread process joint |
5
|
No process joint (1/4NPT internal thread on chamber flange) |
|
Item 5: Material of bolts and nuts |
A |
JIS SCM435 3MPa 14MPa |
B |
JIS SUS630 3MPa 14MPa |
C |
JIS SUH660 3MPa 14MPa |
|
Item 6: Installation Method |
-2
|
Vertical piping connection, high pressure on the right, upper installation process joint |
-3
|
Vertical piping connection, high pressure on the right, lower installation process joint |
-6
|
Vertical piping connection, left high pressure, upper installation process joint |
-7
|
Vertical piping connection, left high pressure, lower installation process joint |
-8
|
Horizontal piping connection, high pressure on the right side |
-9
|
Horizontal piping connection, high pressure on the left side |
|
Item 7: Electrical Interface |
0
|
G1/2 internal thread, one electrical interface |
2
|
1/2NPT internal thread two electrical interfaces without blind plugs |
3
|
Pg13.5 internal thread two electrical interfaces without blind plugs |
4
|
M20 internal thread with two electrical interfaces, no blind plugs |
5
|
G1/2 internal thread two electrical interfaces, one blind plug |
7
|
1/2NPT internal thread two electrical interfaces, one blind plug |
8
|
Pg13.5 internal thread two electrical interfaces, one blind plug |
9
|
M20 internal thread with two electrical interfaces and one blind plug |
|
Item 8: Hidden Display Table |
D |
Digital display table |
E |
Digital display strap measurement range setting button |
N |
not have |
|
Item 9: Installing the bracket |
A |
JIS SECC 2 "pipe installation (flat type) |
B |
JIS SUS304 2 "pipe installation (flat type) |
C |
JIS SECC 2 "Pipe Installation (L-type) |
D |
JIS SUS304 2 "Pipe Installation (L-type) |
N |
not have |
|
|