Jinhu Borui Instrument Co., Ltd
Home>Products>Dual channel ultrasonic water meter
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    13915181617
  • Address
    Jinhu County Industrial Park, Jiangsu Province
Contact Now
Dual channel ultrasonic water meter
Product features: 1. Dual channel measurement, more accurate and stable 2. Wide range ratio (400:1) 3. High definition and wide temperature LCD displa
Product details

1Dual channel ultrasonic water meterbrief introduction
BRWM type dual channel ultrasonic water meter andMulti channel ultrasonic water meterIt is a new type of water meter based on the principle of ultrasonic time difference for flow measurement and display.
The ultrasonic water meter is equipped with an M-BUS interface by default, which can form a remote meter reading management system through the M-BUS bus and other communication devices. The management department can read the data in the meter at any time, facilitating the statistics and management of user water volume.
The product complies with the national standard GBT 778-2007 Measurement of Water Flow in Closed Full Pipelines for Drinking Cold Water and Hot Water Meters, the verification regulation JJG162-2009 Cold Water Meters, and the industry standard CJ/T 434-2013 Ultrasonic Water Meters.
双声道超声波水表
IIDual channel ultrasonic water metercharacteristic
1. Wide range ratio (400:1)
2. Flow sensor fault reminder, undervoltage reminder, automatic data correction technology
3. High definition wide temperature LCD display
4. Built in lithium battery power supply can be used for (6+1) years or more
5. Equipped with photoelectric interface, supporting handheld infrared meter reading tools for on-site reading
6. Optional M-BUS, 485 or wireless communication interface
7. Wireless interface parameters:
1) Frequency 470MHz~480MHz
2) Spread spectrum modulation method
3) Transmission power<=50mW
4) Emission current<=120mA
5) Receiving current<=10mA
6) Receiving sensitivity<=-130dBm
8. Optional power supply methods:
1) Built in battery power supply
2) M-BUS power supply
3) External power supply, (DC 5~24V)
双声道超声波水表
IIIDual channel ultrasonic water meterTechnical Parameter

Cumulative volume resolution

0.001m3 (when in use) 0.00001m3 (during calibration)

Current traffic resolution

0.001m3/h(When used) 0.001m3/h(During verification)

Quiescent current

< 6uA

Battery life

>(6+1) years

LCD display number of digits

8position

Temperature rating

T30

pressure rating

MAP10

Pressure loss level

p25p40p63

Environmental Severity Level

Blevel

protection grade

IP68

accuracy class

2level

Electromagnetic environment level

E1

Installation method

Horizontal or vertical

Sensitivity level of upstream/downstream flow field

U10/D5Or U5/D3

function

Identification and alarm of pipeline dripping, bursting, and scaling

reverse flow

Measurable reverse flow

Range ratio

DN15~DN40: Q3/Q1(125~400 optional)

DN50~DN400: Q3/Q1(125~250 optional)

Common traffic

qp

DN15: 2.5 m3/h

DN20: 4.0 m3/h

DN25: 6.3 m3/h

DN32: 10 m3/h

DN40: 16 m3/h

DN50: 25 m3/h

DN65: 40 m3/h

DN80: 63 m3/h

DN100:100 m3/h

DN125:160 m3/h

DN150:250 m3/h

DN200:400 m3/h

DN250:630 m3/h

DN300:1000 m3/h

DN350:1000 m3/h(Customizable)

DN400:1600 m3/h


4、 Installation dimensions of dual channel ultrasonic water meter


Nominal diameter DN (mm)

Table body length L (mm)

Connecting flange

flange thickness

C(mm)

Outer diameter of flange D2 (mm)

Thread hole center

Diameter D1 (mm)

connect

bolt

50

200

165

125

4*M16

20

65

200

185

145

4*M16

20

80

225

200

160

8*M16

20

100

250

220

180

8*M16

22

125

250

250

210

8*M16

22

150

300

280

240

8*M20

24

200

350

335

295

12*M20

24

250

450

405

355

12*M24

26

300

500

460

410

12*M24

28

350

550

520

470

16*M24

28

400

600

580

525

16*M27

28

超声波水表安装示意图

5Ultrasonic water meterInstallation precautions

(1) Thoroughly clean the pipeline before installing the ultrasonic water meter to avoid debris damage to the water meter;

(2) Ultrasonic water meters are relatively expensive and precise instruments. Be careful when picking them up and putting them down, and do not lift or pull the meter head or sensor wires; It is strictly prohibited to approach high temperature heat sources such as electrical welding to prevent battery explosions from injuring people and damaging instruments;

(3) Special attention should be paid to the installation position of ultrasonic water meters. The water meter should be avoided from being installed at the upper end of the pipeline (where there may be bubbles in the pipe section), near bends (where vortex flow may occur), and away from pumps and other equipment (which may cause pulsating flow);

(4) The connecting pipes at the upstream and downstream of the ultrasonic water meter should be consistent with the diameter of the water meter and cannot be reduced in diameter;

(5) The direction indicated by the arrow on the body of the ultrasonic water meter is the direction of water flow and must not be installed in reverse;

(6) In order to ensure accurate measurement, a certain length of straight pipe section should be reserved for the installation of ultrasonic water meters. Usually, a straight pipe section of 10 times the pipe diameter length should be reserved in front of the meter and 5 times the pipe diameter length should be reserved behind the meter;

(7) It is recommended to install a filter with the corresponding diameter at the front end of the ultrasonic water meter; There is a valve with the corresponding diameter installed in front of the watch and it can be separated from the watch body for future maintenance and repair.


超声波水表现场

6、 Product manual

If you need a detailed product manual, please download it yourself from the technical support section, or contact online customer service to send it directly to you.


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!