Shanghai Baipu Industrial Development Co., Ltd
Home>Products>Druck Platinum Resistance Temperature Probe Calibration Instrument from the United States
Druck Platinum Resistance Temperature Probe Calibration Instrument from the United States
Brief description: The Druck Platinum Resistance Temperature Probe Calibration Instrument (DPI811, DPI812) from the United States is an ideal tool for
Product details

Druck Platinum Resistance Temperature Probe Calibration Instrument from the United States

(DPI811、DPI812)

Product features:

lDPI811/DPI812 is a tool for measuring and simulating RTD sensors, and is an ideal tool for inspecting RTD probes, indicators, recorders, and controllers. It supports 8 standard RTDs and is a full range, high reliability, easy-to-use handheld calibrator launched by General Electric Sensing and Measurement. It provides users with a good solution for process parameter testing and calibration

lMeasurement/simulation of thermal resistance signal output, 2, 3, 4-wire automatic detection, temperature testing and maintenance, transmitter calibration, circuit setting and diagnosis, switch value testing, support for IDOS pressure module, maintenance and upkeep * tools

l8 types of RTD temperature sensors (D100, Ni100, Ni120, PT50, PT100, PT200, PT500, PT1000) can be measured and simulated to automatically detect two-wire, three wire, and four wire RTDs

lCompatible with pulse type temperature transmitter

lStep/ramp output, Z-large/Z-small/average value, reading lock and other functions

Technical indicators:

lOperating environment: Temperature range of -10 to 50 degrees Celsius; Humidity 0-90%, non condensing

lProtection level: IP54, Dustproof and splash proof design

lVibration: DEF STAN 66-31, 8.81 and 8.4CAT III

lECM: EN61326-1; 1997+A1; 1998+A2; two thousand and one

lSecurity: EN61010; 2001, SEP grade, CE mark

lDisplay: 48mm × 48mm LCD with backlight, 99999 five bit resolution

lSize: 180 × 85 × 50 (mm)

lWeight: 500g

lBattery: 3 AA batteries, more than 50 hours for measurement, more than 10 hours for 24V circuit power supply

DPI 802/812/822Technical specifications for electrical signal interface:

lMilliampere measurement: 0 to 55mA, accuracy 0.02% rdg

l 24vCircuit power supply:+/- 10% (Z power supply 35mA)

lAutomatic switch value test: Capture open/close signals, 2mA test current

l HARTLoop resistance: menu selectable, default value 250

812The model also has the following functions:

lLoop calibration, providing RTD output and mA current measurement, suitable for calibration of various transmitter displays

l 24VSupply voltage to the transmitter and control circuit

lAutomatic temperature switch test, capturing on and off temperature values

l Hart resistorfunction

lAdditional pressure module can be connected, ranging from 70 mbar to 700 bar

DPI800series

DPI811

DPI812

test type

Platinum resistance probe

Platinum resistance probe

Indicator (pressure measurement)

 

 

Calibration instrument (measurement/analog output)

correct

correct

Temperature display instrument (dual input/differential)

 

 

0-55MAMeasurement (providing 24V power supply)

 

correct

Switch quantity test

 

correct

HARTloop resistance

 

correct

IDOSIntelligent digital pressure module

Note 1

Note 1

Programmable stepper/ramp output

correct

correct

Reading retention/Z small/Z large/average/alarm/migration

correct

correct

25Pressure unit, flow quantification, leakage testing

Note 2

Note 2

1000Point data storage, RS232 interface

Note 3

Note 3

Note 1: For the external pressure module, please refer to the IDOS list

Note 2: When used in conjunction with IDOS pressure module

Note 3: Refer to option E

IDOSPlug and play:

Each module can be interchanged between devices without the need for setup or instrument calibration

Measurement and simulation

standard

range

accuracy

Pt50(385)

IEC 751

-200Up to 850 degrees

0.5linear measure

Pt100(385)

IEC 751

-200Up to 850 degrees

0.25linear measure

Pt200(385)

IEC 751

-200Up to 850 degrees

0.6linear measure

Pt500(385)

IEC 751

-200Up to 850 degrees

0.4linear measure

Pt1000(385)

IEC 751

-200Up to 400 degrees

0.2linear measure

D100(392)

JIS1604-1989

-200Up to 650 degrees

0.25linear measure

Ni100

DIN43760

-60Up to 250 degrees

0.2linear measure

Ni120

MINCO7-120

-80Up to 260 degrees

0.2linear measure

Ohms

 

0-4000

0.1-1.3Ω

DPI812*Characteristics:

lMeasure 0-55.000mA with an accuracy of 0.02% of the reading plus 3 final words (including temperature effects of 10-30 degrees)

lTemperature coefficient: -10 to 10 degrees, 30 to 50 degrees, 0.002% PS/degree

lSwitch detection: open and close, 2mA current

lCircuit power output: 24V ± 10% (Z high current 35mA)

l HartLoop resistance: 250 Ω (menu selection)

lElectrical socket: 4mm socket

Item number

product description

DPI 811

Druck Platinum Resistance Temperature Calibration Instrument from the United States

DPI 812

Druck Platinum Resistance Temperature Calibration Instrument from the United States

Druck Platinum Resistance Temperature Probe Calibration Instrument from the United States

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!