Shanghai Yadu Electronic Technology Co., Ltd
Home>Products>Digital three-phase ammeter
Product Groups
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    18018578786
  • Address
    No. 22, Lane 928, Wenxiang Road, Songjiang District, Shanghai
Contact Now
Digital three-phase ammeter
Digital three-phase ammeter: YK4I series [Digital three-phase ammeter] Model specification: YK4I-24 Panel size: 120 × 120mm Hole size: 111 × 111mm Mod
Product details
数显三相电流表
Digital three-phase ammeter:YK4I series   Digital three-phase ammeter

Model and specification: YK4I-24 Panel size: 120 × 120mm Hole size: 111 × 111mm

Model and specification: YK4I-94 Panel size: 96 × 96mm Hole size: 91 × 91mm

Model and specification: YK4I-34 Panel size: 80 × 80mm Hole size: 76 × 76mm

Model and specification: YK4I-A4 Panel size: 72 × 72mm Hole size: 67 × 67mm

Model and specification: YK4I-D4 Panel size: 48 × 48mm Hole size: 45 × 45mm(No additional features)

Note: Accuracy of three-phase ammeter: 0.5 level, optional 485 communication, transmission output, input, alarm output, etc

Digital three-phase ammeter

1、 Function of digital three-phase ammeter:

A digital three-phase ammeter can be used in conjunction with transformers to measure three-phase current parameters in the power grid. It uses digital LED display and has the advantages of high accuracy, strong isolation, stable performance, and anti vibration. It can set PT and CT changes and can directly replace the original pointer three-phase ammeter.

1. Digital three-phase ammeter:Equipped with high-performance processing chips and independent measurement chips, it has high measurement accuracy and fast operating speed.
2. Digital three-phase ammeter: measures three-phase current, CT can be set arbitrarily.
3. Digital three-phase ammeter:Adopting LED digital display.
4. Digital three-phase ammeter: Input rated current: AC5A AC1A.

Shanghai YaduDigital displayThree-phase ammeter

IIDigital displayTechnical specifications of three-phase ammeter

Accuracy of digital three-phase ammeter: display accuracy of 0.5 level
Digital three-phase ammeter display: The display screen is a full four digit LED digital tube display
Digital three-phase ammeter input:
Standard input current: AC1A, AC5A (can be set by expanding the range through CT, please specify when ordering)
Current impedance:<20M Ω
Current overload: continuous overload: 1.2 times instantaneous overload: current 10 times (5 seconds)
Frequency: 50, 60HZ ± 10%

Digital three-phase ammeter power supply:
Working power supply: AC220V, AC/DC80-265V, AC380V, DC24V, DC48V power supply. Please specify when ordering
Power consumption: ≤ 5VA

Digital three-phase ammeter output module:
Pulse output: 2-channel power pulse output, optocoupler relay, constant: 5000imp/Kwh (Kvarh)
Switching output: 2 or 4 switching inputs
Switching output: 2-channel or 4-channel switching output
Analog output: 1-4 channels
Communication interface: RS485 interface MODBUS-RTU protocol, baud rates of 1200, 2400, 4800, 9600 optional

Digital three-phase ammeter isolation withstand voltage: input and power>2kV, input and output>1kV, power box output>2kV
Insulation resistance: ≥ 100M Ω
Working conditions for digital three-phase ammeter: ambient temperature: -10~55 ℃, relative humidity ≤ 93%, no corrosive gas field, altitude ≤ 2500m

IIIDigital displaySchematic diagram of three-phase ammeter selection:

Digital three-phase ammeter model

YK4I-24

YK4I-94

YK4I-34

YK4I-A4

YK4I-D4

  basic function

Measure three-phase current

Communication (C)

1 route (optional)

1 route (optional)
1 route (optional)
1 route (optional)
not have
Transmission (M)
1-3 routes (optional)
1-3 routes (optional)
1 route (optional)
1 route (optional)
not have
Entering (K)
4-way (optional)
4-way (optional)
2 channels (optional)
2 channels (optional)
not have
Open (Alarm J)
2 channels (optional)
2 channels (optional)
2 channels (optional)
2 channels (optional)
not have
Panel size
120×120
96×96
80×80
72×72
48×48
Hole size
111×111
91×91
76×76
67×67
45×45
Power supply
Standard AC220V (except for communication and alarm, AC/DC80~265V power supply must be selected for other auxiliary functions),
Optional power supply without auxiliary functionsA3: AC380VD2: DC24VD4: DC48VAD: AC/DC80~265V)

 IIIDigital displayExample diagram of three-phase ammeter wiring

数显三相电流表接线图

4、 Digital three-phase ammeterPhysical shooting:

数显三相电流表

Power series products   
Digital single-phase ammeter:YK4I-21
DC current record table YA201R Single phase current voltage power factor table: YK4UIH series Single phase current recording table YA201R
Digital three-phase ammeter: YK4I series
DC Voltage Record Table YA201R Single phase current voltage frequency meter: YK4UIF series Three phase current recording table YA203R
Single phase voltmeter:YK4U series
Active Power Record Table YA201R Single phase current voltage active power meter: YK4UIP series Single phase voltage record table YA201R
Three phase voltmeter: YK4U series
Reactive Power Record Table YA201R Single phase current voltage reactive power meter: YK4UIP series Three phase voltage record table YA203R
LCD three-phase voltmeter:YK4U series
Frequency Record Table YA201R DC voltmeter: YK5U series Electricity Record Table YD300R
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!