Description: Product features: • Robust design • Tight pressure up to 300 bar • Long term stable temperature sensor, years of recognition • 4... 20 mA
Product details

Product Features:

  • Robust Design
  • Press tightly300bar
  • Long term stable temperature sensor, Years of recognition
  • 4...20 mAAnalog output, exist2Wire system
  • Further adjustable through software parameters% RH, g/m3, ,g/m3, ppm V/V. g/kg.
  • CSProvide service software for data storage and calibration.

FA 300-2Measuring dew point meter, region1 The pressure dew point is located in the explosion area, and the explosion-proof rating is:

FA 300-2 Ex : I 2 G Ex ia IIC T4

Established an explosion-proof approved area1Dew point measuring instrumentFA300-2Now it can be used in Industries in explosive areas,FA300-2 EXCan only be used in conjunction with approved sensor supply instruments, safety barriers, or electrochemical separation components. The maximum allowable value for use isU0 = 30 VI0 = 100mAZui maximum valueP0 = 1 WZui maximum value

FA 300 ExTechnical Parameter

measuring range

The pressure dew point is ºCtd

FA 300-2 Ex

-80...20ºCtd = 4...20 mA

Pressure Range

-1 ... 300bar

power supply

24 VDC (10...30VDC)

accuracy

± 0.5ºCBetween -10 and 50ºCtd± 2ºCAt -40ºCtd

output

4...20mAexist2Wire technology

Protection level

IP 65

EMC

pass throughDIN EN 61326

operate temperature

-20... 70 ºC

storage temperature

-40...80 ºC

Load analog output

< 500Ω

Threaded installation

G1/2”stainless steel

Housing material

polycarbonate

Sensor protection

50umStainless steel sintered filter

order No

describe

0699 3070

FA 300 Ex,Pressure dew point measuring instrument

0699 3590

exist350barThe following measurement slots

0699 4004

Special extended analog output to other humidity parameters

0554 3071

Built in safety power supply Safety Barrier

main unit

Main unit on the wall

Product features:

Detachable tightening clip for easy wiring

VA400/410Consuming sensors Electrical isolation of pulse output

2Relay output(230 VAC,3A)Alarm signal amplification at dew point sensorFA400, FA416

The protection of live parts cannot be touched inside

Technical Parameter:

Technical parameters of wall mounted main unit

size

118 X 133 X92mm (W x H x D)

power supply

100-240 VAC, 10VA, 50-60Hz

output

24VDC, 0.35A

relay

2Chip, conversion contact,230VAC,3A

order No:

order No

name

0554 0108

VA/FAseries The main unit of the wall mounted relay,100-240V, 10VA, 50-60Hz,24VDC,0.35A

0699 3340

Main unit on the guide rail100-240 VAC/24VDC ,0.35A

0554 0107

power supply100-240VAC//24VDC, VA/FA 400The series is0.35A 2Rice Noodles

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!