Product Features:
- Robust Design
- Press tightly300bar
- Long term stable temperature sensor, Years of recognition
- 4...20 mAAnalog output, exist2Wire system
- Further adjustable through software parameters% RH, g/m3, ,g/m3, ppm V/V. g/kg.
- CSProvide service software for data storage and calibration.
FA 300-2Measuring dew point meter, region1 The pressure dew point is located in the explosion area, and the explosion-proof rating is:
FA 300-2 Ex : I 2 G Ex ia IIC T4
Established an explosion-proof approved area1Dew point measuring instrumentFA300-2Now it can be used in Industries in explosive areas,FA300-2 EXCan only be used in conjunction with approved sensor supply instruments, safety barriers, or electrochemical separation components. The maximum allowable value for use isU0 = 30 VI0 = 100mAZui maximum valueP0 = 1 WZui maximum value
FA 300 ExTechnical Parameter | |
---|---|
measuring range |
The pressure dew point is ºCtd |
FA 300-2 Ex |
-80...20ºCtd = 4...20 mA |
Pressure Range |
-1 ... 300bar |
power supply |
24 VDC (10...30VDC) |
accuracy |
± 0.5ºCBetween -10 and 50ºCtd± 2ºCAt -40ºCtd |
output |
4...20mAexist2Wire technology |
Protection level |
IP 65 |
EMC |
pass throughDIN EN 61326 |
operate temperature |
-20... 70 ºC |
storage temperature |
-40...80 ºC |
Load analog output |
< 500Ω |
Threaded installation |
G1/2”stainless steel |
Housing material |
polycarbonate |
Sensor protection |
50umStainless steel sintered filter |
order No |
describe |
---|---|
0699 3070 |
FA 300 Ex,Pressure dew point measuring instrument |
0699 3590 |
exist350barThe following measurement slots |
0699 4004 |
Special extended analog output to other humidity parameters |
0554 3071 |
Built in safety power supply Safety Barrier |
main unit
Main unit on the wall :
Product features:
Detachable tightening clip for easy wiring
VA400/410Consuming sensors Electrical isolation of pulse output
2Relay output(230 VAC,3A)Alarm signal amplification at dew point sensorFA400, FA416
The protection of live parts cannot be touched inside
Technical Parameter:
Technical parameters of wall mounted main unit | |
---|---|
size |
118 X 133 X92mm (W x H x D) |
power supply |
100-240 VAC, 10VA, 50-60Hz |
output |
24VDC, 0.35A |
relay |
2Chip, conversion contact,230VAC,3A |
order No:
order No |
name |
---|---|
0554 0108 |
VA/FAseries The main unit of the wall mounted relay,100-240V, 10VA, 50-60Hz,24VDC,0.35A |
0699 3340 |
Main unit on the guide rail100-240 VAC/24VDC ,0.35A |
0554 0107 |
power supply100-240VAC//24VDC, VA/FA 400The series is0.35A, 2Rice Noodles |