English

Beijing Jiahua Zhongxin Technology Co., Ltd
Home>Products>Detu testo 340 industrial flue gas analyzer
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    13671068345
  • Address
    Tiantong Xiyuan Third District, Dongxiaokou Town, Changping District, Beijing
Contact Now
Detu testo 340 industrial flue gas analyzer
1、 Product introduction: 1. The continuously increasing fuel costs have made it increasingly important to use flue gas analysis to improve the combust
Product details

1、 Product Introduction:
1. The continuously increasing fuel costs have made it increasingly important to use flue gas analysis to improve the combustion efficiency of boilers. A practical, easy-to-use, and portable smoke analyzer is the ideal choice. The testo 340 comes standard with only an O2 sensor, and the other three sensors can be selected and matched according to different applications. The compact design and reliable technology make the testo 340 suitable for various applications such as environmental monitoring; Energy saving monitoring; Testing of fixed engines; Turbine inspection;
2. Pre calibrated plug and play backup sensors, 3 freely selectable sensor slots (standard O2, at least 2 sensors to work) CO, COlow, NO, NOlow, NO2, and SO2
3. The testo 340 comes standard with differential pressure/flow rate measurement function: * range extension function, standard with single sensor range extension or optional range extension for all sensors
4. Automatic flow control air pump
5. Modular smoke probe
6. Data storage function
7. Optional: Data transfer, connected to EasyEmission computer software via USB
8. 10 built-in fuels, 10 user-defined fuels - fuel coefficient can be calculated through easyEmission software
9. The testo 340 requires at least 2 sensors to operate, and can be equipped with up to 4 sensors

2、 Product parameters:

parameter

Range

resolution

Accuracy

O2

0~25 Vol.%

0.01 Vol.%

±0.2 Vol.%

CO (H2)

0~10000ppm

1 ppm

± 10ppm or ± 10% measurement value (0-200ppm)

± 20ppm or ± 5% (201~2000ppm)

±10%(2001~10000ppm)

NO

0~3000ppm

1 ppm

±5ppm (0~99ppm)

±5%(>100ppm)

NO2

0~500ppm

0.1 ppm

±10ppm (0~+199ppm)

± 5% measurement value (other ranges)

SO2

0~5000ppm

1 ppm

±5ppm (0~100ppm)

± 5% measurement value (other ranges)

flue gas temperature

-40 ~ 1200℃

0.1℃

±0.5℃(0~99℃)

± 0.5% measurement value (other ranges)

Pull force measurement

-40 ~ +40hPa

0.01hPa

±0.03hPa(-2.99~+2.99hPa)

± 1.5% measurement value (other ranges)

differential pressure measurement

-200 ~ +200hPa

0.1hPa

±0.5hPa(-49.9~+49.9hPa)

± 1.5% measurement value (other ranges)

Absolute pressure measurement

600~1150hPa

1hPa

±10hPa

Calculation Parameters

Combustion Efficiency

0~120%

0.1%


Smoke loss

0~99.9%

0.1%


flue gas dew point

0~ 99.9℃

0.1℃


CO2 (calculated)

0~CO2 * high value

0.01 Vol.%

±0.2 Vol.%

Storage

100 folders, 10 locations per folder, 200 sets of data per location, for a total of 200000 sets of data

pumping flow

0.6L/min

Positive pressure resistance

+50hPa

Negative pressure resistance

-200hPa

fuel

Built in 10 types of fuels, 10 user-defined fuels, and test gases

Total weight of the instrument

≤960g

size

283×103×65mm

operate temperature

-5~+50℃

storage temperature

-20~+50℃

display

Graphic display, 160 × 240 pixels

protection grade

IP 40

Physical display

340.jpg

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!