YS6060 is a domestically produced desktop grating spectrophotometer independently developed by 3nh company with complete independent intellectual property rights, TFT true color 7-inch capacitive touch screen, full light source, lighting mode: reflection D/8 °, transmission D/0 ° (including UV/exclusion UV measurement), accurate and stable color measurement, large storage capacity, powerful PC expansion function, used for laboratory color accurate analysis and transmission.
Technical characteristics of desktop spectrophotometer
1. High hardware configuration: 7-inch TFT pure color capacitive touch screen; Bluetooth 4.0; Concave grating;
2. Dual array 256 pixel CMOS detector; High lifespan and stable full spectrum LED/UV LED;
3. Measure the reflection and transmission spectra of the sample, with precise Lab data that can be used for color matching and accurate color transfer;
4. Caliber automatic recognition, with four calibers of Φ 25.4/15/8/4mm to switch freely, while taking into account the special needs of customers;
5. Temperature monitoring and compensation, with built-in temperature sensors to monitor and compensate for the testing environment, ensuring more accurate measurement results;
6. The testing wavelength range is 360-780nm, with built-in 400nm/420nm cut-off for more professional UV testing;
7. Independent light source detector, constantly monitoring changes in the light source to ensure its reliability;
8. Multiple measurement modes: quality control mode, sample mode, to meet the needs of more customers;
9. Multiple optional accessories: reflective sample clamping tool, transmission fixing bracket, micro hole 4mm transmission fixture, instrument inverted testing fixture, suitable for more working conditions;
10. Large capacity storage space, capable of storing approximately 40000 pieces of test data;
11. Built in camera for framing and positioning;
12. PC software has powerful extension functions.
![]() |
![]() |
![]() |
![]() |
Reflection measurement: using D/8 structure (diffuse illumination, 8 ° direction), in accordance with IS07724/1 CIE, ASTM, DIN, and JIS standards. | Transmission measurement: using D/0 structure (diffuse illumination, 0 ° direction reception), in compliance with ISO, CIE, ASTM, and DIN standards. | Measurement of liquid, powder, and solid samples in industries such as plastic electronics, paint and ink, textile and clothing printing and dyeing, printed paper products, automotive, medical, cosmetics, and food | Automatic caliber recognition with four different calibers of Φ 25.4/15/8/4mn, allowing for flexible switching and meeting the special needs of customers; |
Application fields of desktop spectrophotometer
Used for precise color analysis and transmission in the laboratory; Plastic electronics, paint and ink, textile and clothing printing and dyeing, printing, paper products, automotive, medical, cosmetics, and food industries are widely used in color transfer and quality control in scientific research institutions, laboratories, and other industries.
Desktop spectrophotometer | ||
Product model | YS6060 | |
Lighting method | Reflection: D/8 (diffuse illumination, 8 ° direction reception); SCI/SCE measurement; Including UV/exclusion UV measurement; Transmission: D/0 (diffuse illumination, 0 ° direction reception) SCI/SCE measurement; Including UV/exclusion UV measurement; Haze (ASTM D1003); Complies with the standard CIE No.15, GB/T 3978,GB 2893,GB/T 18833,ISO7724/1,ASTM E1164,DIN5033 Teil7 |
|
characteristic | Used for precise color analysis and transmission in the laboratory; Color transfer and quality control of reflective and transparent samples in industries such as plastic electronics, paint and ink, textile and clothing printing and dyeing, and printing. |
|
Integral sphere size | Φ154mm | |
Lighting source | 360~780nm combination LED light source, 400nm cutoff light source, 420nm cutoff light source | |
Spectral method | Concave grating | |
a sensor | 256 pixel dual array CMOS image sensor | |
Measuring wavelength range | 360~780nm | |
Wavelength interval | 10nm | |
Half bandwidth | 5nm | |
Reflectance measurement range | 0~200% | |
Measuring caliber | Reflection: Φ30mm/Φ25.4mm,Φ18mm/Φ15mm,Φ10mm/Φ8mm,Φ6mm/Φ4mm; Transmission: Φ30mm/Φ25.4mm remarks: 1. Switch caliber automatic recognition 2. Customers can configure the aperture and lens position according to their needs |
|
Light containing method | Reflective SCI/SCE, transmissive SCI/SCE | |
color space | CIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99 | |
colour-difference formula | ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99,ΔE(Hunter) | |
Other chromaticity indicators | WI(ASTM E313,CIE/ISO,AATCC,Hunter), YI(ASTM D1925,ASTM 313), The same color spectral index Mt, Stain fastness, color fastness, strength, coverage APHA/Hazen/Pt Co (Platinum Cobalt Index), Gardner Index 8 degrees glossiness, 555 tone classification, haze (ASTM D1003) Saybolt index |
|
Observer's perspective | 2°/10° | |
Observing light source | D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,DLF,TL83,TL84,TPL5,U30 | |
display | Spectral chart/data, sample chromaticity value, color difference value/graph, color chart, color simulation, qualified/unqualified results, color deviation | |
Measurement time | About 2.4 seconds (testing SCI/SCE simultaneously takes about 5 seconds) | |
Repeatability | Spectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.04% (400~700nm: within 0.04%): Chromaticity value: Φ 25.4mm/SCI, Δ E * ab within 0.01 (after preheating and calibration of the instrument, measure the average value of the whiteboard 30 times at intervals of 5 seconds) Spectral transmittance: Φ25.4mm/SCI, Standard deviation within 0.05% (400~700nm: within 0.04%): Chromaticity value: Φ 25.4mm/SCI, Δ E * ab within 0.02 (after preheating and calibration of the instrument, measure the average value of the whiteboard 30 times at intervals of 5 seconds) |
|
Inter station difference | Φ 25.4mm/SCI, Δ E * ab within 0.12 (average value measured on 12 color plates of BCRA series II) | |
size | Length X width X height=370X300X200mm | |
weight | About 9.6kg | |
Power supply mode | DC 24V, 3A power adapter for power supply | |
Lighting source lifespan | More than 3 million measurements in 5 years | |
display | TFT true color 7-inch, capacitive touch screen | |
Interface | USB, Bluetooth ® 4.0, Printing Serial Port | |
Store data | 5000 standard samples and 40000 test samples (SCI/SCE count as one data point) | |
language | Simplified Chinese, Traditional Chinese, English, (Customizable in German, French, Spanish) | |
Operating temperature range | 0~40℃(32~104°F) | |
Storage temperature range | -20~50℃(-4~122°F) | |
Standard attachments | Power adapter, manual, quality management software (download), data cable, standard calibration board, black calibration box, transmission black baffle, sample holder, 25.4 caliber, 15 caliber, 8 caliber, 4 caliber, transmission testing fixture components | |
Optional Accessories | Micro printer, micro hole (4mm) transmission testing fixture assembly, inverted instrument testing fixture, culture dish | |
Note: | If there are any changes, no further notice will be given |