Beijing Zhongke Environmental Testing Instrument Co., Ltd
Home>Products>DW-100 single specimen low-temperature brittleness testing machine
DW-100 single specimen low-temperature brittleness testing machine
DW-100 Single Sample Method Low Temperature Brittle Testing Machine I. Application XCY-II Single Sample Method Rubber Low Temperature Brittle Testing
Product details

DW-100 single specimen low-temperature brittleness testing machine

1、 Purpose:

DW-100The single sample method rubber low-temperature brittleness testing machine is used to determine the highest temperature at which the vulcanized rubber sample fails under specified conditions due to impact, which is the brittleness temperature; It is possible to conduct comparative identification of the performance of rubber and other elastic materials under low temperature conditions, and to determine the brittleness temperature and low-temperature performance of different rubber materials or different formulations of vulcanized rubber. Therefore, in terms of quality inspection of scientific research materials and their products, as well as control of production processes, they are all excellent. This instrument is based onGB/T1682-2014A compressor refrigeration equipment designed according to national standards and carefully developed. This equipment adopts a cascade imported compressor refrigeration technology, utilizing the principle of thermal equilibrium and circulating stirring to achieve automatic uniform cooling and constant temperature of the sample.

DW-100 single specimen low-temperature brittleness testing machine

2、 Technical parameters

1Test temperature:-70℃—0℃(-70-60Two options available)

2Impact method: Spring impact

3Parameters of impact spring

a.Free state: diameter19mm, Length85-90mm

b.Compressed state: Length40±1mm, load108-118N

4Cooling rate:-20~-40Approximately ℃1.0/min

-40~-60Approximately ℃0.7/min

-60~-70Approximately ℃0.5/min

5Distance from the center of the impactor to the lower end of the gripper:11±0.5mm

6Impact head radius:R1.5±0.1mm

7Distance from the impact head to the specimen:25±1mm

8Sample size: Length is25.00mmThe width is6.0mm, thick as2.0mm.

9After constant temperature, conduct the experiment3minTemperature fluctuation within time:< ±0.5

10Cold well capacity: approximately for large cold wells4L

11Cooling medium:99.7%Anhydrous ethanol (to be prepared by the customer)

12Mixing motor:8W

13Working power supply220V~240V,50Hz,1.5kW

14External dimensions:900×505×800mm(Length x Height x Width)

15Weight: Approximately150kg

threeafter-sale service

One year warranty,Lifetime maintenance, regular follow-up visits, listening to customer suggestions, and establishing customer service records;

offer freeOur company promises to provide technical support and guidance services for customers' phone calls1We promise to respond within hours and send technical service personnel to the site for resolution24Personnel dispatched within hours (excluding special circumstances such as statutory holidays)