English

Shanghai Aolong Xingdi Testing Equipment Co., Ltd
Home>Products>DT3100 Coating Thickness Gauge
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
  • Address
    No. E1, Lane 288, Yuyang Road, Songjiang District, Shanghai
Contact Now
DT3100 Coating Thickness Gauge
DT3100 Coating Thickness Gauge
Product details

Product Introduction

This instrument is a portable measuring device that can quickly, non destructively, and accurately measure the thickness of coatings and plating layers. It can be used in both laboratories and engineering sites. By using different probes, various measurement needs can also be met. This instrument can be widely used in manufacturing, metal processing industry, chemical industry, commercial inspection and other testing fields. It is an essential instrument for material protection professionals.

Ultra low power consumption: normal operating current is less than3mACan work continuously300More than hours;

Powered by AA dry batteries;

Quick measurement: Fast measurement speed, even in statistical state, can be quickly measured and timely counted without any delay;

Two thickness measurement methods, magnetic and eddy current, are used to measure the thickness of non-magnetic coatings on magnetic metal substrates, as well as the thickness of non-conductive coatings on non-magnetic metal substrates;

available11Planting probe(F400TheF1TheF1/90°F10TheF5TheN400TheN1TheN1/90°CN02TheN10TheFN2)

There are two measurement methods: continuous measurement method(CONTINUE)And single measurement method(SINGLE);

There are two working modes: direct mode(DIRECT)And grouping method(A-B)

There are five statistical measures: mean(MEAN), maximum value(MAX)Minimum value(MIN)Test frequency(NO.), standard deviation(SDEV);

There are two methods to calibrate the instrument, and the basic calibration method can be used to correct the systematic error of the measuring head;

Basic calibration indication function: a user-friendly basic calibration interface that automatically prompts the current calibration point number;

Having storage function: capable of storing768A measurement value;

Having data browsing function: can browse all measurement data and statistical data;

It has a deletion function: it can delete individual suspicious data that appears during measurement, as well as all data in the storage area, in order to conduct new measurements;

Limits can be set: automatic alarms can be triggered for measurement values outside the limits;

Equipped with Bluetooth wireless printing function: capable of printing measurement values, statistical values, and boundary values;

Having andPCThe function of machine communication (Bluetooth wireless communication): It can transmit measurement values and statistical values toPCMachine for further processing of data;

It has the function of timely indication of power supply and battery level;

There is a buzzing sound during the operation process;

It has an error prompt function, which provides error prompts through screen display or beeping sound;

There are two shutdown modes: manual shutdown mode and automatic shutdown mode;

Technical Specifications

Probe model

F400

F1

F1/90°

F3

F10

working principle

magnet feel should

measurement range(μm)

0~400

0~1250

0~3000

0~10000

Low resolution limit(μm)

0.1

0.1

1

10

indicated value

error

A little calibration(μm)

±(3%H+1)

±(3%H+5)

±(3%H+10)

Two point calibration(μm)

±((1~3)%H+0.7)

±((1~3)%H+1)

±((1~3)%H+5)

±((1~3)%H+10)

test

condition

Minimum curvature radius(mm)

convex

1

1.5

straight and flat

5

10

The diameter of the smallest area(mm)

F3

F7

F7

F20

F40

Critical thickness of matrix(mm)

0.2

0.5

0.5

1

2


Probe model

N400

N1

N1/90°

CN02

N3

working principle

vortex flow

Measurement range(Mm)

0~400

0~1250

10~200

0~3000

Low resolution limit(μm)

0.1

0.1

1

1

indicated value

error

A little calibration(μm)

±(3%H+0.7)

±(3%H+1.5)

±(3%H+1)

±(3%H+25)

Two point calibration(μm)

±[(1~3%H+0.7)

±[(1~3)%H+1.5]

___

±((1~3)%H+25)

test

condition

Minimum curvature radius(mm)

convex

1.5

straight and flat

Just straight

25

The diameter of the smallest area(mm)

F4

F5

F7

F50

Critical thickness of matrix(mm)

0.3

0.3

unrestricted

50μmaluminum foil

Standard configuration:

host

1Taiwan

F1(orN1)Probe

1branch

Product packaging box

1a

communication cable

1article

reflectance standards

5piece

Iron matrix (or aluminum matrix)

1block

Instruction Manual

1this

communication software

1set

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!