Application areas: mainly used in industries such as metal, rubber, plastic, electronics, aviation, aerospace, new energy, building materials, cables, new materials, etcConduct temperature rapid change tests on products in the above industries, detect the physical and chemical changes that occur during the testing process, and optimize the products based on the test results.
Product features:1 New touch screen microcomputer program controller,P.I.DSelf calculation function, automatic temperature control.
2 The appointment activation function protects against occupational injuries during the energy storage process.
3 The independent over temperature alarm function interrupts operation when the set temperature is exceeded, and provides sound and light prompts to the operator to ensure that the test operation does not cause accidents and laboratory safety is effectively guaranteed.
4 The entire series comes standard with a program controller, which is more energy-efficient than traditional models45%Left and right, faster response time50%).
5 The control system is modular, safe, stable, and efficient. In case of emergencies (such as power outages), parameters are automatically saved, and there is a call recovery function. In addition, it has functions such as over temperature protection, over pressure protection, water shortage protection, over-current protection, compressor overload protection, and leakage protection
6 Removable with fixed casters, easy to move and secure.
7 You can choose between two slot impact or three slot stepped impact.
8 Automatic defrosting function ensures uninterrupted testing process and improves testing efficiency.
9 The following accessories can be added according to customer requirements: external communication port(485perhapsUSB)Printing system, inert gas control SMS alarm function inside the box,UDisk storage function, etc.
Provide services:1 Shanghai authoritative metrology department metrology report (negotiation)
model |
DRS-50(A.B.C) |
DRS -80(A.B.C) |
DRS -100(A.B.C) |
DRS -150(A.B.C) |
DRS-200(A.B.C) |
DRS-300(A.B.C) |
DRS -480(A.B.C) |
|
|
temperature |
High temperature chamber |
60-200℃ |
||||||
Warm-up time |
60~-200℃make an appointment20minute |
|||||||
Low-temperature chamber |
A: -55~10 ℃ B: -70~10 ℃ C: -80~10 ℃ |
|||||||
Precooling Time |
A: 20~-55 ℃make an appointment60MinutesB: 20~-70 ℃make an appointment75MinutesC: 20~-80 ℃make an appointment90minute |
|||||||
laboratory |
A: -40~150 ℃ B: -50~150 ℃ C: -60~150 ℃ |
|||||||
recovery time |
High temperature exposure/Low temperature exposure(30Minutes), recovery time:10minute |
|||||||
Component transfer |
10second |
|||||||
temperature fluctuation |
±1℃ |
|||||||
Temperature deviation |
±2.5℃ |
|||||||
control system |
Microcomputer touch screen balanced temperature controller |
|||||||
External material |
High quality cold-rolled steel plate, surface electrostatic spraying |
|||||||
Inner liner material |
SUSlevel304stainless steel |
|||||||
Insulation material |
Polyurethane foam plus superfine glass fiber cotton |
|||||||
compressor |
semi-closed/Fully enclosed |
|||||||
Inner cavity (width)*deep*tallmm) |
400x320 x 400 |
500x400 x 400 |
550x400 x450 |
680x500 x450 |
680x600 x500 |
800x750 x500 |
800x930 x550 |
|
Appearance (width)*deep*tallmm) |
1400x1260 x1850 |
1500x1400x1850 |
1550x1400 x1950 |
1680x1650 x1950 |
1680x1800 x2000 |
1800x1950 x2000 |
1800x2250x2050 |
|
Packaging (width)*deep*tallmm) |
1550x1410 x2050 |
1650x1550 x2050 |
1700x1550 x2150 |
1830x1800 x2150 |
1830x1950 x2200 |
1950x2100 x2200 |
1950x2400x2250 |
|
supply voltage |
AC220V/AC380V/50Hz |
|||||||
ambient temperature |
5~35 ℃ |
|||||||
remarks:1 Our company undertakes various types of temperature, humidity, light intensity, pressure, vacuum degree, gas concentration, gas flow rate, etc
Shut down the device.
2 Equipment testing conditions: no load, no strong magnetism, no vibration, ambient temperature20℃Relative humidity of the environment50%RH.