Shanghai Xuanren Environmental Protection Instrument Co., Ltd
Home>Products>DPD residual chlorine measuring instrument
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    13701858271
  • Address
    Room 103, Building 1, Lingang Excellence Science and Technology Park, No. 877 Jiuxin Road, Songjiang District, Shanghai
Contact Now
DPD residual chlorine measuring instrument
The DPD residual chlorine measuring instrument Cl 3000 measures free chlorine or total chlorine based on the DPD colorimetric method, with a measureme
Product details

GermanyWTWDPD residual chlorine measuring instrumentCl 3000
– DPD
colorimetry

Characteristics of DPD residual chlorine measuring instrument

· Measurement of residual chlorine or total chlorine

· Low operating costs

· Easy to operate– 30Tian free maintenance

· DPDStandard colorimetric method

· User selects measurement cycle

· Suitable for drinking water or sewage

· 2A programmable alarm

· 4-20mAandRS-485 Modbusoutput

· USEPArecognize

DPD residual chlorine measuring instrumentCl 3000based onDPDMethod for measuring free chlorine or total chlorine, with a measurement range of0-10 mg/lThe residual chlorine measuring instrument includes a power supply, optical sensor, and display screen, and is installed in oneIP66Inside a corrosion-resistant casing. The measurement reading is consistent with the laboratory/The portable photoelectric colorimetric residual chlorine meter is the same. Output with standards4-20mAandRS485 ModubsThe residual chlorine measuring instrument has a movable measuring slot and a transparent window in the optical part, which can clearly observe the reaction of the sample and reagent. The measurement accuracy is±5%(Measurement range)0-6 mg/l)And±10%(Measurement range)6-10 mg/l). The residual chlorine measuring instrument has a selectable measurement cycle timefrom110Seconds to10minute. At least unmanned operation time30Oh my god. The reagents are ordered separately and supplied in powder form. They should be filled with water before use.

Technical parameters of DPD residual chlorine measuring instrument

Measuring principle

DPDStandard method for measuring residual chlorine or total chlorine

measurement range

0 – 10 mg/L Cl2(ppm)

measurement accuracy

0 – 6.00 mg/L Cl2(ppm)

±5 %Reading or±0.03 mg/L Cl2(ppm)Take the bigger one

6.01–10.00 mg/L Cl2(ppm)

±10 %reading

resolution

0.01 mg/L Cl2(ppm)

measurement period

adjustable: 110second– 10Minutes (default value:2.5Minutes)

display

LCDBacklight display

call the police

2Road programmable240VAC 2A

standard output

isolated4-20 mAAnd bidirectionalRS 485 Modbus

Operating temperature

5°…40°C

Sample pressure

0.34…10.3 bar

Sample flow rate

200 – 400 mL/min

power supply

100 – 240 VAC, 47 – 63 Hz, 150VA

Protection level

IP 66

certification

CEauthentication,ETL UL61010B-1ETLc CSA 22.2 No. 101-1-92

weight

3.6 kgWithout reagents

Overall dimensions

406 mm x 406 mm X 229 mm

DPD residual chlorine measuring instrument
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!