Fire pipeline flowmeterIt has the characteristics of high precision, high reliability, and long service life. To ensure product quality, meticulous research and control are carried out at every stage of the product structure, material selection, process development, production equipment, and factory testing, and a complete flow calibration and detection system is provided. In order to meet the needs of measurement sites, high-pressure electromagnetic flowmeter systems and plug-in electromagnetic flowmeter systems have been developed. Especially, plug-in flowmeters have good economy, timeliness, and stability when applied in large-diameter pipeline systems. Pre installation allows for non-stop installation and maintenance, making it easy to use. Make our electromagnetic flowmeter system suitable for various fields such as petroleum, energy, metallurgy, food, environmental protection, and water conservancy.
Fire pipeline flowmeterMain performance parameters of the converter
- output signal4-20mA DC(Active, load resistance)0-750Ω)
0-10mA DC(Active, load resistance)0-1.5KΩ)
Frequency (passive)1-5000Hz
Pulse (passive) upper limit5000CP/S
MODBUS RS-485,RS232(Optional),Special orders are required.
- power supply85-260V AC,45-63Hzperhaps24V DC
- work consume less than20W(After connecting the sensor)
- Supporting sensorsDN3~DN3000
Model specification table
KHLDE |
Intelligent electromagnetic flowmeter |
|
|||||||||||||
Nominal Diameter |
-xxx |
50Representing DN50, if the diameter is followed by I, it represents an insertion type |
|||||||||||||
Electrode form |
-1 |
Standard fixed type |
|||||||||||||
2 |
Scraper type |
||||||||||||||
3 |
Removable and replaceable |
||||||||||||||
Electrode material |
0 |
stainless steel |
|||||||||||||
1 |
Platinum (Po) |
||||||||||||||
2 |
Ha Shi B (HB) |
||||||||||||||
3 |
Ha Shi C (Hc) |
||||||||||||||
4 |
Tantalum (Ta) |
||||||||||||||
5 |
Titanium (Ti) |
||||||||||||||
Lining material |
1 |
chloroprene rubber |
|||||||||||||
2 |
polyurethane |
||||||||||||||
3 |
F4(PTFE) |
||||||||||||||
4 |
F46(FEP) |
||||||||||||||
5 |
F40(E-TFE) |
||||||||||||||
6 |
P0polypropylene |
||||||||||||||
7 |
PPSpps |
||||||||||||||
Rated pressure (MPa) |
-4.0 |
DN10-80 |
|||||||||||||
1.6 |
DN100-150 |
||||||||||||||
1.0 |
DN200-1000 |
||||||||||||||
0.6 |
DN1100-2000 |
||||||||||||||
0.25 |
DN2000 |
||||||||||||||
operation temperature |
E |
<80℃ |
|||||||||||||
H |
<80℃ |
||||||||||||||
ground ring |
-0 |
No grounding ring |
|||||||||||||
1 |
With grounding ring |
||||||||||||||
protection grade |
0 |
IP65 |
|||||||||||||
1 |
IP68 |
||||||||||||||
Converter form |
0 |
Integrated |
|||||||||||||
1 |
split type |
||||||||||||||
communication |
0 |
not have |
|||||||||||||
1 |
RS-485 |
||||||||||||||
2 |
Hart |
||||||||||||||
3 |
ModBus |
||||||||||||||
4 |
PAbus |
||||||||||||||
5 |
FFbus |
||||||||||||||
Housing material |
-0 |
carbon steel |
|||||||||||||
1 |
stainless steel |
||||||||||||||
Body flange |
0 |
carbon steel |
|||||||||||||
1 |
stainless steel |
||||||||||||||
Install the matching flange |
-0 |
carbon steel |
|||||||||||||
1 |
stainless steel |
||||||||||||||
Power supply mode |
1 |
24VDC(Iour≥0.5A) |
|||||||||||||
2 |
Internal battery power supply |
||||||||||||||
3 |
220VAC |
||||||||||||||
Flow range |
-xxx |
Example: 1000 represents a large flow rate of 1000m ³/h |
|||||||||||||