DMF-T-62S Direct Electromagnetic Pulse Valve
The DMF-T-62S straight through electromagnetic pulse valve is a compressed air switch for the dust cleaning and blowing system of the pulse bag filter
Product details
The DMF-T-62S straight through electromagnetic pulse valve is the compressed air "switch" of the pulse bag filter dust cleaning and spraying system. Under the control of the output signal from the pulse valve blowing control instrument, the filter bags are blown and cleaned one by one to maintain the resistance of the dust collector within the set range, ensuring the processing capacity and dust collection efficiency of the dust collector.
Working principle of electromagnetic pulse valve:
The diaphragm divides the electromagnetic pulse valve into two chambers, front and rear. When compressed air is connected, it enters the rear chamber through the throttle hole. At this time, the pressure in the rear chamber presses the diaphragm assembly tightly against the output port of the valve, and the electromagnetic pulse valve is in the "closed" state.
The electrical signal of the pulse jet control device causes the electromagnetic pulse valve to move backwards, the vent hole in the rear chamber of the valve opens, the rear chamber rapidly loses pressure, the diaphragm component moves backwards, compressed air is blown through the valve output port, and the electromagnetic pulse valve is in the "open" state.
The electrical signal of the pulse jet control instrument disappears, the electromagnetic pulse valve is reset, the vent hole in the rear chamber is closed, and the pressure in the rear chamber increases, causing the diaphragm component to tightly adhere to the output port of the valve. The electromagnetic pulse valve is then in the "closed" state
The DMF-T-62S straight through electromagnetic pulse valve is a straight through valve, with an angle of 180 ° between its inlet and outlet (the centerline of the inlet and outlet is the same straight line). Its inlet is connected to the air storage cylinder, and its outlet is connected to the spray pipe. The airflow is smooth and can provide a qualified ash cleaning pulse.