GB/T 18460-2001 "IC Card Prepaid Electricity Sales System"
GB/T 17215-2002 "Level 1 and Level 2 Static AC Active Energy Meters"
The voltage sampling circuit adopts resistance voltage division method.
The RS485 communication interface is powered by an independent power supply and has anti-static and surge protection circuits.
Adopting patented technology (patent number: ZL2012200509249) and low-power magnetic holding relay.
Using standard IC cards as the medium for power transmission, with one meter and one card, the data is encrypted and has good security.
Electricity usage data can be copied back to the IC card.
Standard reference voltage (V): 220
Standard current (A): 1.5, 2.5, 5, 10, 15, 20, 30
Maximum current (A): not greater than 100 and not greater than 10 times the standard current
Standard reference frequency (Hz): 50
Merit: Level 1, Level 2
Optional infrared, RS485, or carrier communication methods.
Optional real-time clock, historical data, and event recording functions.
Optional functions such as alarm, credit, overload detection, etc.
IC cards can be selected as either logical encryption cards or CPU cards.
Various extension protocols are available for selection.