Zhejiang Tuoqiang Electric Co., Ltd
Home>Products>DDSY6607 plug-in single-phase prepaid energy meter
DDSY6607 plug-in single-phase prepaid energy meter
2、 Working principle
Product details

1、 Overview

DDSY6607 electronic single-phase prepaid energy meter adopts advanced application specific integrated circuit design and fully automatic surface mount(SMT)Production process manufacturing. The circuit design and component selection of the electric energy meter are based on a large environmental tolerance, which can ensure long-term stable operation of the whole machine, high precision, high overload, low power consumption, and high reliability performance. Adopting advanced intelligence that meets international standardsICThe card technology implements a prepaid method and has a built-in magnetic holding relay. By controlling the relay to control the on and off of the load, the function of urging users to buy electricity before using it can be achieved.

The product complies withGB/T17215.321-20081Level and2Static AC Active Energy Meter andGB/T 18460.3-2001ICCard prepaid electricity sales system3Part: All technical requirements for prepaid energy meters.

2、 Working principle

1Working principle diagram

The electric energy meter obtains voltage sampling signals from the voltage divider, current sampling signals from the current divider, voltage current product signals from the multiplier, and then generates a counting pulse proportional to the product of voltage and current through frequency conversion. Through frequency division, it drives the stepper motor to measure electricity.




Electricity metering pulse is transmitted through a photoelectric couplerCPUProcessed and stored in memory after computation. Managed by a computer information system, throughICCard reader/writer, capable of writing a certain amount of power and monitoring requirementsICThe microprocessor system in the card input table, throughCPUAfter calculation, provide display and alarm status signals.

3、 Specifications, models, and technical parameters:

1. Specification and model

specifications

model

accuracy class

Voltage

(V)

Current specifications(A

DDSY6607

1.0

220

5(20)10(40)2080

2. Main technical parameters:

a、 Basic error:

LOAD

Power factor

Percentage error limit (%)

0.05IbI<0.1Ib

1.0

±1.0

0.1IbIImax

±0.6

0.1IbI<0.2Ib

0.5(lagging) 0.8(Advanced)

±1.0

0.2IbIImax

±0.6

b、 Gas parameters (reference conditions):

Starting current:0.4 % Ib

Power consumption: voltage circuit<1.0W3.0VA

current line< 1.0VA

Stealth: equipped with logic anti creep circuit

Voltage range:220V±10%

Working temperature range:-25~ +65

Storage time of power-off data>20year

4、 Installation and use

1. The electricity meter has been inspected and qualified before leaving the factory, and sealed with a lead seal before installation and use. If there is no lead seal or it has been stored for too long, relevant departments should be asked to re verify and seal it before installation and use.

2. The electric meter should be installed in a dry and ventilated place, and the bottom plate for installing the electric meter should be fixed on a sturdy, fire-resistant, and non vibrating wall. The height of the electric meter should be about1.8mabout.

3. Install and wire according to Figure 1 and Figure 2, tighten the wiring screws, and secure the connecting plate inside the terminal box.

4. The reading of an electric meter connected through a transformer must be multiplied by the transformation ratio to obtain the actual amount of electrical energy.

5. One table, one card: held by the userICCards cannot be exchanged. If lost, please go to the power supply department(Electricity sales office)Purchase an additional one.

6. Preparation for purchasing electricity: Before purchasing electricity, users mustICInsert the card into the card slot once to facilitate sending the data in the table back to the computer database.

7. Electricity purchase method: When selling electricity, theICCard insertionICCard reader/writer, simultaneously operating computer, will be used

Encrypt and write the account number, pre purchased electricity, alarm electricity, capacity limiting method, and capacity limiting power, etcICCard.

8. Electricity card usage: Insert the power purchase card into the card slot. If it is a valid power purchase card, the electricity meter will automatically read the data into the meter,LCDThe display screen shows the remaining amount, purchase amount, total purchase amount, total electricity consumption, user number, and constant in sequence. Please keep them properly when unplugging the card.

9. Operation display: During the operation of the electricity meter, it alternately displays the remaining amount, purchase amount, total purchase amount, total electricity consumption, user number, and constant in the meter.

10. Overcapacity alarm: During the operation of the electricity meter, if the "alarm indicator light" flashes rapidly, it warns the user that the electricity has been exceeded. If the meter is set to the over capacity power-off limit mode, then the over capacity electricity will be used60In seconds, the brake will be pulled3minute; If the user inserts the card and responds, the power supply can be immediately restored.

11. Accumulation limit: If purchased electricity+remaining electricity>Accumulation limit(10000kWh)If the purchased electricity is not read in, the display will show“Error=10”Reminder: The battery level in the card is still valid.

12. Warning reminder: When the remaining battery level in the meter is less than the "audible and visual alarm battery level", the "alarm indicator light" will flash (with an interval of1Display a reminder to the user to purchase electricity in seconds.

13. Power outage warning: When the remaining power in the meter is less than the "trip alarm power", the "alarm indicator light" will remain on, and the LCD will display the "trip" prompt. The relay will trip. At this time, the user can insert the power purchase card into the meter once, and the meter will close. The "alarm indicator light" will continue to stay on. At this time, the user should quickly go to the power supply department to purchase electricity to avoid being unable to purchase electricity in time and unable to use electricity. If this table cannot be found after pulling the switchICCard, can be borrowed from neighborsICInsert the card to restore power supply.

14. Power purchase reminder: When the remaining power in the meter is less than the "alarm power", the "alarm indicator light" will remain on as a constant reminder.

15. Fault declaration: When the remaining power is displayed as zero or negative, a "trip" prompt will be displayed. If the meter continues to operate, the user should immediately purchase electricity and proactively report the situation to the power supply department.


5、 Transportation and Storage

1. The table should not be subjected to severe impact during transportation and unpacking, and according toGB/T15464-1995The Technical Conditions for Packaging of Instruments and Meters stipulate transportation and storage.

2. The energy meter should be stored in its original packaging at an ambient temperature of-25~ +55℃, relative humidity not exceeding85%In an environment without corrosive gases in the air. When storing electric energy meters on shelves, the stacking height of the entire box should not exceed5The stacking height of individual packaged electric energy meters after unpacking shall not exceed10Only.

6、 Quality Assurance

Within 18 months from the date of manufacture of the electric meter, if the user complies with the requirements specified in this manual and the lead seal is still intact, and it is found that the electric meter does not meet the requirements specified in the technical specifications, the manufacturer will provide free repair or replacement.

appendixAMeter display content


Display serial number

LCD display content

Power on display content


1

Full screen display


Normal display content


1

Remaining amount

XXXXXX.XXfirst


2

Last purchase amount of electricity

XXXXXX.XXfirst


3

Total purchase amount of electricity

XXXXXX.XXfirst


4

Total Power

XXXXXX.XX kWh


5

User ID

NNNNNNNN


6

Electric meter constant

NNNNNN


Display content of plug-in power card


1

money to purchase electric energy

P= XXXX.XX kWh


2

Remaining amount

XXXXXX.XX kWh


3

Total electricity consumption

XXXXXX.XX kWh


Insert the settings card to display the content


1

Display card type

C=05


Insert the reset card to display the content


1

Display successful zeroing

CE=00


2

The number of times to reset the card is0

Error=12


Insert and check the display content of the power card (parameter viewing card)


1

User ID

NNNNNNNN


2

Electricity meter number

NNNNNNNN


3

Sound and light alarm amount

B1 XXXX.XXfirst


4

Brake alarm amount

B2 XXXX.XXfirst


5

Credit limit

XXXXXX.XXfirst


6

Electricity price

XX.XXfirst


7

Electric meter constant

NNNNNN


8

Accumulated electricity consumption

XXXXXX.XX kWh


9

State of charge

XXXXXX.XXfirst


10

Accumulated purchase amount of electricity

XXXXXX.XXfirst



appendixBError code description


Serial Number

LCD display content

Error code description

1

Error=01

Card reading error, the data read twice does not match

2

Error=02

Card reading data checksum error

3

Error=03

After opening an account, it is not allowed to use a factory card or open another account

4

Error=04

The user number in the card does not match the user number in the table

5

Error=05

Verification card password error

6

Error=06

The account opening card has already been transferred on other forms

7

Error=07

This form has already been transferred and cannot be reopened

8

Error=08

The user number in the card does not match the user number in the table

9

Error=09

Incorrect number of power purchases

10

Error=10

Accumulate more electricity than10000No input allowed

11

Error=11

The credit limit is greater than100No input allowed

12

Error=12

The number of times the system clears the card is0

13

Error=13

The number of times the super reset card has been reset is0

14

Error=14

The preset battery level is greater than200No input allowed

appendixCLCD rendering



Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!