1、 Overview
DDSY6607 electronic single-phase prepaid energy meter adopts advanced application specific integrated circuit design and fully automatic surface mount (SMT) production process manufacturing. The circuit design and component selection of the electric energy meter are based on a large environmental tolerance, which can ensure long-term stable operation of the whole machine, high precision, high overload, low power consumption, and high reliability performance. Adopting advanced intelligent IC card technology that meets international standards to achieve prepaid payment, with built-in magnetic holding relay. By controlling the relay to control the on and off of the load, the function of urging users to buy electricity before using it can be achieved.
Main features: Application of computer management, purchasing electricity first and then using it; The maximum operating power can be limited within the rated current range (limited by the power supply department); One meter, one card, dedicated card, no power loss after card loss, can be used after card replacement; Electric cards can transmit data bidirectionally and automatically power off to alert users when purchasing electricity; When the battery level is zero, the power will automatically trip and cut off; And it has certain anti-theft software design, etc.
The product meets all technical requirements of GB/T17215.321-2008 "Level 1 and Level 2 Static AC Active Energy Meters" and GB/T 18460.3-2001 "IC Card Prepaid Electricity Sales System Part 3: Prepaid Energy Meters".
2、 Working principle
1Working principle diagram
The electric energy meter obtains voltage sampling signals from the voltage divider, current sampling signals from the current divider, voltage current product signals from the multiplier, and then generates a counting pulse proportional to the product of voltage and current through frequency conversion. Through frequency division, it drives the stepper motor to measure electricity.
|
The electric energy metering pulse is sent to the CPU through a photoelectric coupler for processing, and after calculation, it is stored in the memory. The information system is managed by a computer, and through an IC card reader/writer, a certain amount of electricity and monitoring requirements are written into the IC card input table of the microprocessor system. After being processed by the CPU, it provides display and alarm status signals.
3、 Specifications, models, and technical parameters:
1. Specification and model
specifications model |
accuracy class |
Voltage (V) |
Current specification (A) |
DDSY6607 |
1.0 |
220 |
5(20)、 10 (40), 20 (80) |
2. Main technical parameters:
a、 Basic error:
LOAD |
Power factor |
Percentage error limit (%) |
0.05Ib≤I<0.1Ib |
1.0 |
±1.0 |
0.1Ib≤I≤Imax |
±0.6 |
|
0.1Ib≤I<0.2Ib |
0.5(lag) 0.8 (lead) |
±1.0 |
0.2Ib≤I≤Imax |
±0.6 |
b、 Gas parameters (reference conditions):
Starting current: 0.4% Ib
Power consumption: Voltage line<1.0W, 3.0VA;
Current line<1.0VA
Stealth: equipped with logic anti creep circuit
Voltage range: 220V ± 10%
Working temperature range:- 25℃~ +65℃
Power failure data storage time>20 years
4、 Installation and use
1. The electricity meter has been inspected and qualified before leaving the factory, and sealed with a lead seal before installation and use. If there is no lead seal or it has been stored for too long, relevant departments should be asked to re verify and seal it before installation and use.
2. The electric meter should be installed in a dry and ventilated place, and the bottom plate for installing the electric meter should be fixed on a sturdy, fire-resistant, and vibration resistant wall. The height of the electric meter is about 1.8 meters.
3. Install and wire according to Figure 1 and Figure 2, tighten the wiring screws, and secure the connecting plate inside the terminal box.
4. The reading of an electric meter connected through a transformer must be multiplied by the transformation ratio to obtain the actual amount of electrical energy.
5. One table, one card: The IC card held by the user cannot be exchanged. In case of loss, a replacement card should be purchased from the power supply department (sales office).
6. Preparation for purchasing electricity: Before purchasing electricity, the user must insert the IC card into the card slot once to facilitate sending the data in the meter back to the computer database.
7. Electricity purchase method: When selling electricity, insert the IC card into the IC card reader and operate the computer to use it
Encrypt and write the account number, pre purchased power, alarm power, capacity limiting method, and capacity limiting power into the IC card.
8. Electricity card usage: Insert the power purchase card into the card slot. If it is a valid power purchase card, the meter will automatically read the data into the meter. The LCD display screen will show the remaining amount, power purchase amount, total purchase amount, total power consumption, user number, and constant in sequence. Please keep the card properly when unplugged.
9. Operation display: During the operation of the electricity meter, it alternately displays the remaining amount, purchase amount, total purchase amount, total electricity consumption, user number, and constant in the meter.
10. Overcapacity alarm: During the operation of the electricity meter, if the "alarm indicator light" flashes rapidly, it warns the user that the electricity has been exceeded. If the meter is set to the over capacity power-off limit mode, it will be turned off for 3 minutes after 60 seconds of over capacity power consumption; If the user inserts the card and responds, the power supply can be immediately restored.
11. Accumulation limit: If the purchased electricity+remaining electricity>accumulation limit (10000kWh), the purchased electricity will not be read in, and the display will show an "Error=10" prompt, indicating that the stored electricity in the card is still valid.
12. Warning reminder: When the remaining power in the meter is less than the "audible and visual alarm power", the "alarm indicator light" will flash (with an interval of 1 second) to display a reminder to the user to purchase electricity.
13. Power outage warning: When the remaining power in the meter is less than the "trip alarm power", the "alarm indicator light" will remain on, and the LCD will display the "trip" prompt. The relay will trip. At this time, the user can insert the power purchase card into the meter once, and the meter will close. The "alarm indicator light" will continue to stay on. At this time, the user should quickly go to the power supply department to purchase electricity to avoid being unable to purchase electricity in time and unable to use electricity. If the IC card of this meter cannot be found after pulling the switch, you can borrow a neighbor's IC card to insert it and restore power supply.
14. Power purchase reminder: When the remaining power in the meter is less than the "alarm power", the "alarm indicator light" will remain on as a constant reminder.
15. Fault declaration: When the remaining power is displayed as zero or negative, a "trip" prompt will be displayed. If the meter continues to operate, the user should immediately purchase electricity and proactively report the situation to the power supply department.
5、 Transportation and Storage
1. The table should not be subjected to severe impact during transportation and unpacking, and should be transported and stored in accordance with GB/T15464-1995 "Technical Conditions for Packaging of Instruments and Meters".
2. The energy meter should be stored in its original packaging in an environment with an ambient temperature of -25 ℃ to+55 ℃, a relative humidity not exceeding 85%, and no corrosive gases in the air. When storing electric energy meters on shelves, the stacking height of the entire box should not exceed 5 boxes, and the stacking height of a single packaged electric energy meter after unpacking should not exceed 10.
6、 Quality Assurance
Within 18 months from the date of manufacture of the electric meter, if the user complies with the requirements specified in this manual and the lead seal is still intact, and it is found that the electric meter does not meet the requirements specified in the technical specifications, the manufacturer will provide free repair or replacement.
Appendix A Electricity Meter Display Content
|
Display serial number |
LCD display content |
|
|||
Power on display content |
|
|||||
1 |
Full screen display |
|
|
|||
Normal display content |
|
|||||
1 |
Remaining amount |
XXXXXX.XXfirst |
|
|||
2 |
Last purchase amount of electricity |
XXXXXX.XXfirst |
|
|||
3 |
Total purchase amount of electricity |
XXXXXX.XXfirst |
|
|||
4 |
Total Power |
XXXXXX.XX kWh |
|
|||
5 |
User ID |
NNNNNNNN |
|
|||
6 |
Electric meter constant |
NNNNNN |
|
|||
Display content of plug-in power card |
|
|||||
1 |
money to purchase electric energy |
P= XXXX.XX kWh |
|
|||
2 |
Remaining amount |
XXXXXX.XX kWh |
|
|||
3 |
Total electricity consumption |
XXXXXX.XX kWh |
|
|||
Insert the settings card to display the content |
|
|||||
1 |
Display card type |
C=05 |
|
|||
Insert the reset card to display the content |
|
|||||
1 |
Display successful zeroing |
CE=00 |
|
|||
2 |
Zero card reset times |
Error=12 |
|
|||
Insert and check the display content of the power card (parameter viewing card) |
|
|||||
1 |
User ID |
NNNNNNNN |
|
|||
2 |
Electricity meter number |
NNNNNNNN |
|
|||
3 |
Sound and light alarm amount |
B1 XXXX.XXfirst |
|
|||
4 |
Brake alarm amount |
B2 XXXX.XXfirst |
|
|||
5 |
Credit limit |
XXXXXX.XXfirst |
|
|||
6 |
Electricity price |
XX.XXfirst |
|
|||
7 |
Electric meter constant |
NNNNNN |
|
|||
8 |
Accumulated electricity consumption |
XXXXXX.XX kWh |
|
|||
9 |
State of charge |
XXXXXX.XXfirst |
|
|||
10 |
Accumulated purchase amount of electricity |
XXXXXX.XXfirst |
|
Appendix B Error Code Explanation
Serial Number |
LCD display content |
Error code description |
1 |
Error=01 |
Card reading error, the data read twice does not match |
2 |
Error=02 |
Card reading data checksum error |
3 |
Error=03 |
After opening an account, it is not allowed to use a factory card or open another account |
4 |
Error=04 |
The user number in the card does not match the user number in the table |
5 |
Error=05 |
Verification card password error |
6 |
Error=06 |
The account opening card has already been transferred on other forms |
7 |
Error=07 |
This form has already been transferred and cannot be reopened |
8 |
Error=08 |
The user number in the card does not match the user number in the table |
9 |
Error=09 |
Incorrect number of power purchases |
10 |
Error=10 |
Storage capacity greater than 10000 is not allowed for input |
11 |
Error=11 |
Credit limit greater than 100 cannot be entered |
12 |
Error=12 |
The number of times the system clears the card is 0 |
13 |
Error=13 |
The number of times the super reset card is 0 |
14 |
Error=14 |
Pre set battery level greater than 200 is not allowed to be input |
Appendix C LCD Effect Diagram