D10P-20The calcium ion measuring instrument has a dual channel structure with dual channelsBNCInterface, dual reference interface, dualATCInterface, capable of simultaneously connecting two ion selective electrodes orpHElectrode, measuring the ion concentration orpHSimultaneously measure and display.
D10P-20Calcium ion measuring instrumentcharacteristic:
Ion field effect electrode(ISFET)Mode, optionalISFETElectrode, expanding application fields
● Smart StabilityTMInduction signal balance function, intelligently improving the response speed of the instrument,Shorten the time required for data stability
● Smart AveragingTMData averaging calculation function, intelligently improving the accuracy and reproducibility of measurement data
● Self-TestSelf diagnostic function, intelligent judgment of host working condition and electrode performance
●The desktop watch has an automatic mixing interface, and an optional mixer can evenly mix the sample for more accurate measurement
● 10Group password protection measurement method function, convenient for multi-user operation
●Software network upgrade function ensures that instruments never become outdated
●fully supportFDA 21 CFR Part 11Software (optional) that meets current * grade file management requirements
● 200Group meetsGLPRecord standardized data storage to ensure the authority of data reports
● ACAC power supply (desktop meter) and4×AABattery DC power supply function, no power outage concerns, and can be used outdoors
● LCDLarge backlit LCD screen with bright and clear data display
D10P-20Calcium ion measuring instrumentTechnical indicators:
PH: |
|
measuring range: |
-2.000 - 19.999 |
resolution: |
0.1 / 0.01 / 0.001 pH |
relative accuracy: |
±0.001 pH |
Correction point |
1 - 6drop |
Automatic buffer recognition |
US,NIST,DINCustomize with users |
ion concentration |
|
measuring range |
0 – 19900 M/ppm |
resolution |
1,2,3 Significant digits |
relative accuracy |
±0.1 mVperhaps0.05%(Choose the larger one) |
unit |
ppm,mg/L,M,%Or no unit |
measuring method |
Single known dosage/Reduction method; Double known dosage/decrement method |
Correction point |
2 - 6drop |
Oxidation-reduction potentialORP |
|
measuring range |
±1999.9(mV/RmV/EH) |
resolution |
0.1 mV |
relative accuracy |
±0.1 mVperhaps0.05%(Choose the larger one) |
temperature: |
|
measuring range/resolution: |
-5arrive105 °C / 99.9 °Cbelow0.1, 99.9 °Cthe above1.0 |
relative accuracy: |
± 0.1 °C |
display: |
Large screen backlightLCDSimultaneously display the measurement values of two channels |
input/output: |
|
Electrode input: |
twoBNCInterface, two reference electrode interfaces, twoMiniDINInterface (temperature probe) |
communication: |
two-wayRS232interface,optionalUSBcable |
GLPSoftware Features: |
|
Storage: |
1000 group |
Correction record: |
*After10Group correction data |
User method storage: |
20individual |
Superior self inspection: |
have |
Password protection: |
have |
Network software upgrade/download method: |
have |
power supply: |
Desktop:4 x AABattery; Universal power adapter |
safety certification: |
CE, CSA, UL, T? V, FCC Class A |
Suitable operating temperature: |
5 to 45 °C |
relative humidity: |
5 to 85% |
IPgrade: |
Desktop:IP54,Dustproof and splash proof |