Compact spectrometer
1. Compact infrared spectrometer S90-IR
characteristic:
High sensitivity, uncooled InGaAs detector
Compact casing ensures stable parameters
Diffraction grating, with optional spectral range and resolution
Friendly user interface for Windows XP, Windows 7,32/64 bits.
Spectrometer model |
S90-IR |
Spectral range, nm |
780 - 1700 |
Focal length, mm |
87.7 |
F/number |
1 : seven point seven |
slit |
20 μm х 3mm |
spectral resolution |
Depends on the diffraction grating (see table below) |
Detector model |
G9204-512D |
Number of pixels |
512 |
Pixel size, μm |
25 *500 |
Effective area size, mm |
12.8 *0.5 |
Maximum spectral sensitivity nm |
1550 |
Uniformity sensitivity,% |
± 5 |
Anti ambiguity |
yes |
ADC |
16bit, 125kHz |
Mean square noise |
< 6 ADC counts |
dynamic range |
~ 12000 : one |
time of exposure |
8.2ms – 0.7s (3) (4) |
Processing time, ms |
4.1 |
Thermoelectric cooling |
No |
Operating temperature, С |
10–30 |
computer interface |
Full Speed USB |
Simultaneity |
IN/OUT |
Optical input |
Infrared fiber with a diameter of 0.6mm and a length of 1m, SMA-905 interface |
2. High sensitivity compact spectrometer SC125
Spectrometer model |
SC125- S10420 |
SC125- S7030 |
Spectral range, nm |
200-1100 |
|
Focal length, mm |
125 |
|
F/number |
1 : three point nine |
|
Slit (one to choose) |
Fixed width: 14μm, 30μm and 50μm |
|
resolving power |
Depending on the selected diffraction grating (see table below) |
|
CCD detector model |
S10420-1106 |
S7030-1006 |
Number of pixels |
2068 *70 |
1024 *64 |
Effective number of pixels |
2048 * 64 |
1024* 58 |
Pixel size, μm |
14 *14 |
24* 24 |
Effective area size, mm |
28.672 *0.896 |
24.6 *1.4 |
Maximum spectral sensitivity, nm |
500 |
650 |
Maximum quantum efficiency |
>75 % |
>90 % |
Sensitivity (inconsistency) |
±10 % |
±3 % |
Anti ambiguity |
yes |
No |
ADC |
16bit, 250 kHz |
16bit, 125 kHz |
Mean square noise, ADC counts |
< 12 |
< 7 |
dynamic range |
~ 8000 : one |
~15 000 : one |
time of exposure |
8.3ms - 3s |
8.2ms - 2s |
Processing time, ms |
9.39 |
9.12 |
Thermoelectric cooling |
no |
|
working temperature |
10- 30С |
|
computer interface |
Full Speed USB |
|
Simultaneity |
IN/OUT |
|
Optical input |
Optical quartz fiber dia 0.6mm (optional 0.4mm), length 1m, SMA-905 interface |
|
Size, mm |
158 × 182 × 74 |
|
Weight, kg |
2.2 |
3. Compact wideband spectrometer S100
model |
S100-3648 |
S100-2048 |
S100-1024 |
a spectrometer |
|||
Grating, l/mm (average) |
300 |
||
Dispersion (average), nm/mm |
33.28 |
||
F/Number |
6 |
||
Focal length, mm |
99 |
||
Spectral range, nm |
190 - 1100 |
200 - 1100 |
200-1050 |
Resolution (average), nm |
1.0 |
1.5 |
2.0 |
Linear image sensor |
TCD 1304AP 3648 pixels size 8mkm x 0.2mm |
TCD 1205D 2048 pixels size 14mkm x 0.2mm |
S8378-1024 1024 pixels size 25mkm x 0.5mm |
Minimum exposure time, msec |
7.3 |
4.1 |
2.0 |
Maximum exposure time e, sec |
0.5 |
4.0 |
5.0 |
Max. S/N 1 Scan |
400 : one |
400 : one |
1000 : one |
Anti ambiguity |
no |
yes |
yes |
dynamic range |
900 : one |
1000 : one |
3500 : one |
Photosensitive sensitivity, V/lux*sec 3) |
160 |
80 |
22 (HS) 4.4 (LS) |
Output noise, ADC counts |
18 |
14 |
16 (HS) 3)4.4 (LS) |
ADC resolution |
14 bit, 16384 counts |
||
Simultaneity |
internal, external |
||
computer interface |
Full Speed USB interface |
||
Optical input |
The diameter of the ultraviolet fiber is 0.6 (0.4) mm, and it is 1 meter long, SMA-905 interface |
||
Size, mm |
66 x 86 x 146 |
||
Weight, g |
750 |
Advantages:
Extremely wide range: 190-1100nm - covering the usage band of diffraction gratings
Compact design, high resolution
The user-friendly interface adoptsWindows 98/ME/2000/XP
No external power supply
Quartz fiber optic input
Application:
Laser wavelength control
Plasma control
Spectral quality analysis of any light source between 190-1100nm
4. Micro lens spectrometer S41
Advantages:
Mini Design
User friendly interface, using Windows 98/ME/2000/XP
High linearity and wide dynamic range
Optional spectral range
No need for external power supply
Quartz fiber optic input
Spectrometer model |
S41-I |
S41-II |
S41-III |
F/Number |
1 : six |
||
Entrance slit |
0.04 х 3.0 |
||
Diffraction grating, line density/mm 1) |
1200 |
600 |
600 |
Spectral range, nm |
200 - 400 |
390 - 780 |
754 -1140 |
Dispersion (average) nm/mm nm/pixel |
16.57 0.414 |
33.28 0.83 |
30.27 0.76 |
Spectral resolution (average), nm |
0.9 - 1.2 |
1.7 - 2.5 |
1.6 - 2.3 |
Accuracy, not exceeding, nm |
± 0.5 |
± 0.9 |
± 0.8 |
detector |
Based on the S8378-512Q linear imaging sensor, 512 pixels, size 25mkm x 0.5mm |
||
Minimum exposure time, msec |
1.0 |
||
Max. S/N for 1 Scan |
3500 : one |
||
ADC resolution |
14 bit, 16384 counts |
||
computer interface |
Full Speed USB interface |
||
Optical input |
-The diameter of the ultraviolet fiber is 0.6 (0.4) mm, and it is 1 meter long, SMA-905 interface -Direct input, input through the S41 slit |
||
Size, mm |
129 x 78 x 53 |
||
Weight, kg |
0.76 |
Application:
Spectral analysis of light sources
Spectral research
Analysis of target colors, etc.
5. Compact spectrometer A50/C150-II
Spectrometer model |
S150-200 |
S150-300 |
S150-400 |
S150-600 |
S150-1200 |
S150-1800 |
S150-1800(II) |
S150-1800(III) |
Focal length, mm |
150 |
|||||||
F/Number |
1:12 |
|||||||
Slit width, Mm slit height, mm |
≤ 0.018
3 |
|||||||
Diffraction grating, line density/mm |
200 |
300 |
400 |
600 |
1200 |
1800 |
1800 II order |
1800 III order |
Dispersion (average), nm/mm |
33.15 |
21.5 |
16.2 |
10.5 |
4.7 |
3.0 |
1.3 |
0.8 |
Resolution (average), nm |
0.66 |
0.44 |
0.32 |
0.21 |
0.1 |
0.06 |
0.025 |
0.015 |
Detection range, nm |
200-1100 |
200-1100 |
200-1100 |
200-1100 |
200-1100 |
200-800 |
200-450 |
200-300 |
computer interface |
Full Speed USB interface |
|||||||
Optical input |
The diameter of the ultraviolet fiber is 0.6 (0.4) mm, and it is 1 meter long, SMA-905 interface |
|||||||
Overall size, mm |
155 х 200 х 105 |
|||||||
Weight, kg |
2.5 |
Application:
Laser and LED wavelength characteristics
Plasma control
Spectral Quality Analysis of Any Light Source in the 200-1100nm Range
6. Compact Spectrometers SDH-I/SDH-IV
Focal length mm |
150mm |
||||||||||||||
F/Number |
1: four point four |
||||||||||||||
Narrow slit, mm |
0.016 x 3 or 0.04 x 3 or 0.08 x 3 |
||||||||||||||
computer interface |
Full-Speed or High-Speed USB |
||||||||||||||
Overall size and weight |
(242 х 280 х 113) mm; 4.85 kg |
||||||||||||||
SDH-I spectrometer |
|||||||||||||||
Linear density/mm |
300 |
400 |
600 |
1200 |
1800 |
100 |
|||||||||
Spectral range, nm |
200-1100 |
200-1100 |
200-1100 |
200-1000 |
200-650 |
800-1700 |
|||||||||
Dispersion (average), nm/mm |
21.3 |
15.8 |
10.2 |
4.0 |
3.0 |
65 |
|||||||||
Resolution (FWHM, average), nm |
0.42 1.3 |
0.32 1.0 |
0.22 0.65 |
0.09 0.3 |
0.06 0.2 |
4.0 |
|||||||||
SDH-IV spectrometer |
|||||||||||||||
Spectral range nm |
200-1100 |
200-1100 |
800-1700 |
||||||||||||
Linear imaging sensor |
TCD1304 |
S8378-1024 |
G9212-512S - G9214-512S |
||||||||||||
Effective area |
29.1mm, 3648 pixels 8mkm × 0.2mm |
25.6mm, 1024 pixels 25mkm × 0.5mm |
12.8mm, 512 pixels 25mkm × 0.5mm (0.25mm) |
||||||||||||
Linear density/mm |
900 |
600 |
400 |
300 |
900 |
600 |
400 |
300 |
100 |
400 |
300 |
200 |
|||
Detecting spectral range, nm |
190-390 |
300-600 |
450-905 |
600- 1140 |
200- 380 |
300- 570 |
450- 855 |
600-1140 |
870- 1700 |
900- 1100 |
1065- 1330 |
1295-1700 |
|||
Spectral resolution (FWHM, average), nm |
0.18 |
0.28 |
0.42 |
0.54 |
0.44 |
0.65 |
1.0 |
1.3 |
4.5 |
0.95 |
1.3 |
2.0 |
|||
Advantages:
High resolution: up to 0.06nm
High transmittance: F/Number 4.4
Optional resolution and spectral range
Friendly user interface, using Windows 98/ME/2000/XP