Liaoning Kono Environmental Protection Equipment Co., Ltd
Home>Products>Closed type bypass flow processor equipment
Closed type bypass flow processor equipment
The circulating water side flow processor is developed on the basis of the original full flow water processor, which is used to replace the traditiona
Product details
Kono Closed Side Stream Processor Equipment, Open Side Stream Filter


❀ Product Introduction
The circulating water side flow processor adopts the principle of low voltage electric field and high voltage electrostatic field with superimposed pulses, adjusts the signal source and unit configuration according to the water quality conditions, and only needs to use side flow processing. This technology is the latest research achievement of the National Natural Science Foundation of China's key funding project (approval number:), and is at a leading level internationally. The circulating water side flow processor is developed on the basis of the original full flow water processor, and is suitable for the treatment of sterilization, algae removal, and scale removal in circulating water systems, as well as the removal of suspended solids in water.

❀ Core principles
Efficient pulse low-voltage electric field captures scaling ions in water, and visible scaling is achieved.
The electric field generates microcrystals with excellent anti scaling function, which can continuously prevent scaling for 48 hours.
The patented electrode with catalytic activity produces strong bactericidal factors such as reactive oxygen species, which can kill bacteria and algae.
The active substance forms a dense protective film of Fe3O4 on the inner wall of carbon steel water pipes to prevent corrosion.
Suspended solids in water are efficiently separated and discharged from the system in the water processor, resulting in cleaner water quality.
❀ Main functions
◆ Kill bacteria in water ◆ Kill Legionella ◆ Suppress algae
◆ Waterproof and scale removal ◆ Anti corrosion of equipment and pipelines ◆ Removal of suspended solids

❀ Application Fields
It can be widely used for the treatment of various industrial and domestic water, as well as cooling and circulating water wastewater, such as electricity, petroleum, metallurgy, papermaking, food, beverages, tap water, swimming pools, etc.
❀ Equipment selection and parameters - Reference table for selection of closed bypass flow processor
Selection area External connection size External dimensions Head loss (m) Maximum power (W) Weight (kg)
model Adapt to pipe diameter
(mm)
Inlet and outlet diameter (mm) Discharge outlet (mm) Long L
(mm)
Width W
(mm)
High H
(mm)
KN-PL-80-1.0-1.6 80 25 25 700 570 1100 0.2 ≤50 100
KN-PL-100-1.0-1.6 100 25 25 700 570 1100 0.4 ≤90 100
KN-PL-150-1.0-1.6 150 25 25 700 570 1100 0.7 ≤120 102
KN-PL-200-1.0-1.6 200 25 25 700 570 1100 1 ≤160 110
KN-PL-250-1.0-1.6 250 25 25 700 570 1100 1 ≤200 110
KN-PL-300-1.0-1.6 300 32 25 700 570 1100 1 ≤300 115
KN-PL-350-1.0-1.6 350 32 25 700 570 1100 1 ≤500 120
KN-PL-400-1.0-1.6 400 40 25 700 570 1100 1 ≤600 130
KN-PL-450-1.0-1.6 450 40 25 700 570 1100 1 ≤800 160
KN-PL-500-1.0-1.6 500 50 25 700 570 1100 1 ≤900 180
KN-PL-600-1.0-1.6 600 50 25 700 570 1100 1 ≤1100 190
KN-PL-700-1.0-1.6 700 65 25 700 570 1100 1 ≤1400 236
KN-PL-800-1.0-1.6 800 65 25 700 570 1100 1 ≤1700 250

❀ Processing effect
◆ The heat exchange surface of the heat exchanger is free of scale, maintaining efficient heat transfer;
The total number of bacteria in the cooling water is lower than the national standard value;
There is no algae growth in the cooling water;
Kill Legionella bacteria to meet national standards and prevent "Legionella SARS";
The inner wall of carbon steel water pipes gradually forms a dense protective film of Fe3O4, solving the problem of yellow rust water,
The corrosion rate is lower than the national standard;
The water quality indicators of the cooling water have fully met the national industrial circulating cooling water quality standards
(GB50050-95).

❀ Technical features
Only 1-3% of the water flow rate of the bypass treatment system is required, making installation easy
◆ Good descaling effect
Using a powerful pulsed electric field to kill Legionella bacteria
◆ Remove rust and yellow water
◆ Reduce turbidity
◆ Automatic operation
❀ Equipment Selection and Parameters - Reference Table for Selection of Open Side Flow Water Processor
Selection area External connection size External dimensions Head loss (m) Maximum power (W) Weight (kg)
model Adapt to pipe diameter
(mm)
Inlet and outlet diameter (mm) Discharge outlet (mm) Long L
(mm)
Width W
(mm)
High H
(mm)
KN-PL-80-1.0-1.6 80 25 25 1000 620 1200 6 ≤90 100
KN-PL-100-1.0-1.6 100 25 25 1000 620 1200 6 ≤120 100
KN-PL-150-1.0-1.6 150 25 25 1000 620 1200 6 ≤160 102
KN-PL-200-1.0-1.6 200 25 25 1000 620 1200 6 ≤200 110
KN-PL-250-1.0-1.6 250 25 25 1000 620 1200 6 ≤300 110
KN-PL-300-1.0-1.6 300 32 25 1000 620 1200 4 ≤500 115
KN-PL-350-1.0-1.6 350 32 25 1000 620 1200 7 ≤600 120
KN-PL-400-1.0-1.6 400 40 25 1000 620 1200 5 ≤800 130
KN-PL-450-1.0-1.6 450 40 25 1000 620 1200 7 ≤900 160
KN-PL-500-1.0-1.6 500 50 25 1000 620 1200 4.5 ≤1100 180
KN-PL-600-1.0-1.6 600 50 25 1000 620 1200 5 ≤1300 190
KN-PL-700-1.0-1.6 700 65 25 1000 620 1200 4 ≤1500 236
KN-PL-800-1.0-1.6 800 65 25 1000 620 1200 5 ≤1800 250
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!