Circulating preparation liquid chromatography instrumentIntroduction:
Reverse flow prevention function (device)
Completely solved the problem of backflow that caused damage to the detector and solvent peaks due to back pressure in the preparation of HPLC by circulation. Ensure that the sample will not be lost in areas such as detectors and chromatography columns.
Innovative design
The manual sampler is externally mounted, greatly reducing the time required for replacing sealing rings and other components. At the same time, infusion pumps and detectors can also be removed from the front end, greatly improving the maintainability of the instrument.
Automatic cleaning function
The device is equipped with a brand new automatic cleaning component that can automatically clean the flow path. It can ensure that the instrument is used in a clean state. Similarly, utilizing this function can simplify the process of solvent replacement during chromatographic column replacement.
Use shortcut keys to complete all settings
The device realizes that all settings from infusion to preparation can be completed through shortcut keys (infusion pump flow rate setting, detector setting, cycle switching, automatic cleaning, etc.).
Circulating preparation liquid chromatography instrumentProduct parameters:
model |
LC-9110NEXT |
LC-9130NEXT |
infusion pump |
P-9101B |
P-9104B |
Infusion method |
Series reciprocating double plunger method |
|
Maximum output pressure |
30MPa |
20MPa |
flow rate range |
0.001-9.999ml/min |
0.01-30.00ml/min |
control panel |
8.4inchLCDHand touch screen |
|
pressure display/press limit |
pass throughLCDHand touch screen display\\setting |
|
manual injector |
Rheodyne 7725itype |
|
Sample loop |
3ml(Standard),5ml、10ml(Optional) |
10ml(Standard),5ml、15ml(Optional) |
event marker |
Injection trigger, cycle trigger, collection trigger |
|
Siphon counter |
Siphon table (optional) |
|
Siphon mark |
Display siphon mark in detector signal (optional) |
|
circulatory system |
Built in (manual, automatic) |
|
Circulation mode |
Electromagnetic valve switching |
|
Automatic cycle |
Built in: The maximum setting number is99order |
|
Repeated sampler |
LCD touch screen display and settings100ul-50ml |
|
Manual cycle |
pass throughLCDHand touch screen display\\setting |
|
fraction collector |
standard configuration The biggest33Individual fractions (manually triggered, time triggered) |
|
Automatic Repeat Operating System |
Remember the previous operation process, which can be repeated up to99order |
|
Sequential sampling system |
Injection function to reduce injection time |
|
Back in prevention system() |
Prevent solution reflux by adjusting the solenoid valve |
|
Automatic Cleaning System |
Clean according to program settings |
|
Host size |
464(W)×492(H)×504(D) |
|
Host power supply |
85V-240Vpower800VA |
|
quality |
make an appointment38kg |