1. Features and Applications: Used for measuring building wind loads under wind and rain composite force fields, integrating sensors and signal amplification circuits, with thin thickness and small volume. Can be applied to the surface of buildings for measurement. The measurement will not affect the flow field distribution of the air. Considering the reference pressure design and environment of general testing environment conditions, the specially designed drainage and dust prevention structure can adapt well to the testing environment. Recommended for disaster reduction design and testing purposes such as hurricanes and typhoons.
2. Pressure range: 0 to ± 5 to ± 10kpa
3. Natural frequency: not less than 1000Hz
4. Power supply mode: ± 15VDC
5. Output mode: 0~± 5V
6. Working temperature: -20 ℃~80 ℃
7. Compensation temperature: 0 ℃~70 ℃
8. Overload capacity: ≥ 200% FS
9. Accuracy level and performance indicators:
| Indicator/Rank | accuracy class %FS |
Zero position, sensitivity temperature coefficient ×10-4FS /℃ |
Zero position and maximum deviation preset at full capacitydiffer from %FS |
Zero position short-term drift %FS/24h |
Zero position long-term stability %FS/1 year |
| JA | 0.5 | 5 | 0.5 | 0.15 | 0.5 |
| JB | 0.25 | 3 | 0.5 | 0.1 | 0.3 |
12. Dimensions: Ø 42 × 13mm