Guangzhou Beize Instrument Technology Co., Ltd
Home>Products>CNA-87.130.200PH electrode CNA-87.130.200
CNA-87.130.200PH electrode CNA-87.130.200
Conductivity analyzer UDA2182-CC1-NN2-N-0000 Conductivity meter UDA2182-CC1-CC2-NN-N-0000 Conductivity electrode 04973-X10-333-20-00000 Conductivity e
Product details

Honeywell Online in the United StatesConductivity analyzerUDA2182+Conductivity electrode04973

Conductivity analyzerUDA2182-CC1-NN2-NN-N-0000

Conductivity meter UDA2182-CC1-CC2-NN-N-0000

Conductivity electrode 04973-X10-333-20-00-000

Conductivity electrode 04973-XX1-333-20-00-000

Conductivity electrode 04973-X01-333-20-00-000

Conductivity electrode 04973-001-333-20-00-000

Conductivity electrode5000TC-00-1-000

Conductivity electrode5000TC-00-2-000

Conductivity electrode5000TC-00-3-000

Conductivity electrode5000TC-00-4-000

Honeywell online acid-base concentration analyzer from the United StatesUDA2182+acidity concentration electrode 04905

Acid concentration electrode 04905-X50-44-333-20-000-000

Alkali concentration electrode 04905-X50-33-333-20-000-0000

Acid concentration junction box04905-X50-44-333-X1-000-000

alkaliConcentration junction box04905-X50-33-333-X1-000-0000

Acid concentration electrodeTF-20-K50-H

Alkaline concentration electrodeTF-20-K50-N

The Honeywell UDA2182 pH meter calculates pH by measuring the specific conductivity and positive conductivity of ammonia based pure water, and its working principle complies with the international VBG450 standard. In a pure water environment, pH measurement is affected by factors such as unstable liquid contact potential, static charge, grounding conditions, temperature changes, glass electrode quality, and external interference. The corresponding measures taken can only reduce the impact, but cannot completely eliminate it. Therefore, pure water pH measurement has always been a global problem, manifested in large deviations in pH meter readings, instability, and sensitivity to flow rate.

The Honeywell UDA2182PD pH meter uses conductivity measurement method, effectively avoiding the various drawbacks of pH electrode measurement.

The entire system includes instruments, electrodes, flow tanks, cation exchange columns, valves, flow meters, and corresponding pipelines. All components are concentrated on a stainless steel plate.

The instrument has two electrodes, one with an electrode constant of 0.1 cm-1 for specific conductivity measurement, and the other with an electrode constant of 0.01 cm-1 for positive conductivity measurement.

As shown in the figure on the right, the sample water enters the flow tank 1 through the inlet valve to measure the specific conductivity, then enters the cation exchange column to remove all alkalizing reagents, enters the second conductivity electrode to measure the conductivity, and finally the sample water is discharged after passing through the flowmeter.

Application measurement points:

Suitable for pH measurement of pure water containing one or several alkalizing agents and ammonia added pure water, with a positive conductivity<0.3 μ S/cm, pH 7.5-10.5, and measuring points including feedwater, condensate, steam, internal cooling water, etc.

Working Principle:

The instrument simultaneously measures the specific conductivity value (sample water conductivity) and the cation conductivity value (conductivity exchanged with cation resin) of the sample water, and calculates the pH value of the sample water by the difference between the two.

Features:

1. Less interference factors, high accuracy, AVT water quality error<0.01pH, and stable measurement values

2. Low maintenance requirement, usually does not require calibration, only needs to clean the electrode once a year

3. No consumables, low operating costs

4. Can simultaneously measure pH, specific conductivity, and positive conductivity

5. Suitable for adding one or more types of water such as ammonia, hydrazine, morpholine, ethanolamine, etc

6. Multiple nonlinear temperature compensations are available for different water qualities

7. All components such as the cation exchange column are concentrated on a stainless steel plate, which is beautiful and easy to install

8. Long life titanium electrode, electrode constant accurate to one ten thousandth, high measurement accuracy

9. No pH electrode, no need for pH measurement calibration, instrument maintenance free, no consumption

10. Overall wall mounted, easy to install and maintain

Technical Specifications:

display

Color LED with background light

Screen size: 66.8mm (W) x35.5mm (H)

Lattice number: 128 (W) x64 (H)

Can display two conductivity values, pH, and sample water temperature simultaneously

measurement range

Conductivity: 0.055-200 μ S/cm

pH:7.5~10.5pH

keyboard

10 single keys, wear-resistant

Shell material

GE Valox357

precision

0.5% of the reading

output accuracy

±0.01mA

repetitiveness

0.05%

temperature accuracy

± 0.1 ℃ at -10~100 ℃, ± 1 ℃ at 101~140 ℃

Operating temperature

0~60℃

relative humidity

5-90%, no condensation within 40 ℃ (104 ℉)

analog output

2-channel 0/4~20mA (standard), optional third channel, maximum load 750 Ω

Communication output

Ethernet/RS485 Modbus/Profibus optional

temperature compensation

NaCl (pure water) NH3 (ammonia added pure water), HCl (positive conductivity), PO-4 (phosphate containing boiler water), C4H9NO (morpholine added pure water), etc

power supply

90-264VAC, 47-63Hz, 15VA, E ² PROM power-off memory

Safety Certification

UL/CSA/CE

FM, Class 1, Div2

Overall dimensions

850(H)x 280(W)x 202.5(D)mm

installation dimensions

824 (H) x 254 (W) mm, 4- Ø 10mm mounting hole

Sample water inlet size

1/4 "card sleeve connector

Size of sample water discharge outlet

3/4 "NPT external thread

electrical interface

4x1/2 "wiring holes

Protection level

CSA Type 4X(NEMA 4X)/IP66 外壳

install

Wall mounted

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!