Controlled by an ARM-32 bit microprocessor, it is reliable, stable, and highly intelligent
Fast dynamic response and stable speed
Three phase vector control, automatic balancing of three-phase voltage
High voltage stabilization accuracy
High frequency stability
Adopting a 7-inch touch screen display and control, the interface is beautiful and the parameter display is diverse
VF working curve, specially designed for motor testing, with soft start function of frequency converter and pure sine wave of frequency converter power supply
RS485 communication interface, standard MODBUS-RTU protocol, optional TCP/IP interface, remote viewing and control through mobile APP
Optional features
Programmable variable frequency power supply RS485 interface, with PC or PLC monitoring interface, standard RS485 interface (can be converted to RS232/CAN/RJ45), meets MODBUS-RTU protocol, convenient for remote monitoring. It is possible to set working condition groups and store several sets of voltage, frequency, working time, etc;
The DC28V interface of military intermediate frequency power supply has a DC28V DC input interface and control switch, and the DC28V power supply can be embedded inside the cabinet to form a whole, which is convenient, beautiful, and reasonable;
Input harmonic current suppression components, including 12 pulse rectification, 18 pulse rectification, and 3-21st harmonic filters, can be selected to reduce the input harmonic current of the variable frequency power supply, improve the power factor, and avoid interference from the variable frequency power supply to other devices in the network;
Marine shore power supply protection level, optional outdoor IP65 protection level shell, directly used outdoors, is a marine shore power supply; Alternatively, a containerized power supply room can be chosen to place the power supply inside the container, which can be equipped with environmental temperature control devices, insulation layers, etc;
Wide range input function, optional voltage input range ± 50%, frequency input 25Hz-100Hz, especially suitable for small thermal or hydroelectric power generation occasions. The output can stabilize frequency and voltage.
input | voltage range | Three phase 380V ± 20% (single-phase 220V ± 20%) or other specified voltage |
frequency | 47Hz-63Hz or other frequencies | |
output | modulation scheme | IGBT/SPWM sine wave pulse width modulation method |
output voltage | Three phase 0-520V adjustable, single-phase 0-300V adjustable (higher voltage can be customized) | |
|
Output voltage stability (Average value) | ±1%(可定制更高精度) | |
reaction time | 2mS (for input voltage) | |
Voltage waveform distortion THD | <2% (linear load) | |
output frequency | 41Hz-73Hz adjustable, 50/60/400Hz fixed (optional 100Hz/200Hz, customizable 5-1000Hz) | |
Frequency stability | < 0.1% | |
phase shift | When the load is balanced in three phases or when there is no load, it should be ≤ ± 1 °; 100% three-phase imbalance: ≤± 4 ° | |
Three-phase unbalance degree | Three phase voltage automatic balancing | |
Display diagnosis | Electrical parameter display | Line voltage (L-L), three-phase voltage (L-N), three-phase current, frequency, power |
Resolution of electrical parameter display | Voltage resolution 0.1V; current resolution 0.1A; power resolution 0.1KW | |
Fault diagnosis and display | Overload short circuit fault, IGBT module fault, fuse fault, high temperature fault | |
protect | Input no fuse switch, output no fuse switch, electronic circuit quickly detects overcurrent, overvoltage, overload, overheating, short circuit and automatically trips for protection and alarm | |
Display medium | LCD display (128 * 64) | |
overload capacity | 120%/1h; 150%/1min; 200%/20s | |
Usage environment | Environmental temperature -10~45 ℃, relative humidity 0~90% | |
insulation resistance | DC500V, above 20 M Ω | |
pressure resistance | 1500Vac/10mA without leakage | |