(1%+1) High measurement accuracy

Ultra large capacity storage
Can be connected to an external USB flash drive for convenient data applications
Short measurement response time and fast measurement speed
Split design, strong applicability and stable measurement values
7 types of probes (F400, F1, F1/90 °, F10, N400, N1, CN02) are available for selection, fullMultiple measurement needs of customers
performance metrics
measurement range
F400:0~400μm N400:0~400μm
F1:0~1250μm F1/90:0~1250μm
N1:0~1250μm F10:0~10000μm
CN02:10~200μm
measurement accuracy
F400, N400 probes
One point calibration: ± (2%+0.7) Two point calibration: ± (1%+0.7)
F1, F1/90, N1, CN02 probes
One point calibration: ± (2%+1) Two point calibration: ± (1%+1)
F10 probe
One point calibration: ± (2%+10) Two point calibration: ± (1%+10)
calibration method
One point calibration/Two point calibration/Basic calibration
display resolution
0.1 μ m (measurement range less than 100 μ m)
1 μ m (measurement range greater than 100 μ m)
weight
300g (including battery pack)
working environment
Temperature: 0 ℃~50 ℃ Humidity: 20%~90%
working mode
working method
Direct and group methods
measurement method
Continuous measurement/single measurement
Shutdown mode
Manual shutdown/automatic shutdown
Operation prompt
Music ringtone, error message
signal processing
Threshold limit
Automatic alarm for measurement values outside the limit
data analysis
A histogram can be used to analyze a batch of measurement values
statistic
Mean/Standard Deviation (S.DEV)/
Test frequency (No.)/maximum test value (MAX)/
Small Test Value (MIN)
storage
Thickness value
500 pieces of data
delete
Single suspicious data/all data within the group
input
communication
USB
power supply
battery
Commercial nickel hydrogen/alkaline battery 1.5V
Power Monitoring
Under voltage indication
standard configuration
1 host
1 probe (N1 or F1)
5 standard pieces
1 piece of substrate
Two 1.5V alkaline batteries
1 user manual
Probe model |
F400 |
F1 |
F1/90° |
F10 |
N400 |
N1 |
CN02 |
||||
working principle |
Magnetic induction |
Eddy current |
|||||||||
Measurement range (mm) |
0~400 |
0~1250 |
0~10000 |
0~400 |
0~1250 |
10~200 |
|||||
(Copper plated with chrome 0-40) | |||||||||||
Low resolution (mm) |
0.1 |
0.1 |
10 |
0.1 |
0.1 |
1 |
|||||
indication error |
One point calibration (mm) |
±(3%H+0.7) |
±(3%H+1) |
±(3%H+10) |
±(3%H+0.7) |
±(3%H+1.5) |
±(3%H+1) |
||||
Two point calibration (mm) |
±(1%H+0.7) |
±((1%H+1) |
±(1%H+10) |
±(1%H+0.7) |
±(1%H+1.5) |
-------- |
|||||
|
test conditions |
Small curvature radius (mm) |
convex |
1 |
1.5 |
straight and flat |
10 |
convex |
1.5 |
3 |
straight and flat |
Just straight |
Small area diameter (mm) |
F3 |
F7 |
F7 |
F4 |
F4 |
F5 |
F5 |
F7 |
|||
Critical thickness of substrate (mm) |
0.2 |
0.5 |
0.5 |
2 |
0.3 |
0.3 |
0.3 |
none |
|||