Product details

Beckman Coulter MET ONE HHPC6+HHPC3+HHPC2+Dust Particle Analyzer Air Particle Counter Handheld Air Cleanliness Detector

Advantages

  • Routine monitoring of clean room
    A high-resolution display screen that is easy to read is fully configurable and can display the data of interest in clear large font.
  • Lightweight and suitable for difficult to access HEPA filter leakage scenarios
    The weight of MET ONE HHPC+is only 1.5lbs, and its slim design allows for one handed operation. It is the perfect solution to easily solve the problem of filter leakage in microenvironments and workstations.
  • Cleanroom classification
    Can quickly inspect or verify ISO 5 level (FED STD 100 level) or higher cleanrooms and controlled environments.
  • Visualized trends in particulate matter monitoring
    Save time for on-site analysis to identify particle leakage points
  • Convenient data download
    Data can be downloaded to an Excel spreadsheet via Ethernet using a standard browser
  • Using USB flash drive - Capture data
    Insert the USB flash drive into MET ONE HHPC+and transfer your particle counting data directly to the computer.
  • Connect directly to the computer using a USB cable
    Insert it like a digital camera, and your data will be displayed in Excel format.
  • Place your MET ONE HHPC+on the charging socket in the cleanroom
    Your handheld monitor will be fully charged and ready for you to use at any time. The unique base allows the computer to retrieve data from the particle counter via Ethernet or USB cable
Common application areas:
High tech manufacturing industry
  • Semiconductor wafer fab
  • Hard disk storage manufacturing industry
  • Flat panel display devices
  • LED (Light Emitting Diode)
  • solar energy
  • aerospace
  • PCBA (Printed Circuit Board Assembly)
  • Optical components
  • Printing head manufacturing
  • High precision manufacturing, MEMS (Micro Electro Mechanical Systems), MOEMS (Micro Electro Mechanical Systems)
High tech manufacturing applications
  • Used for routine monitoring of cleanrooms in the high-tech manufacturing industry
  • Used for troubleshooting issues related to particle contamination in high cleanliness production environments
  • Conduct spot checks at key locations
  • Determine the total lead content of the filter
  • The generation of needle shaped particles in process equipment or microenvironment
GMPStandardized manufacturing industry
  • Aseptic packaged food and beverage products
  • Tetra Pak filling line
  • hospital
  • Pharmaceutical formula
  • medical equipment
GMPRelated field applications
  • As part of the Good Manufacturing Practice system, routine monitoring of controlled environments and clean rooms is conducted
  • Ideal choice for ISO 5-7 levels (FED STD 100-10000 levels) control environment
  • Aseptic packaged food, dairy products, and beverage products


Technical parameters:
model 6+ 3+ 3+ 2+
Number 2089311-01 (6 channels) 2089310-02 (3-channel 0.3um) 2089310-08 (3-channel 0.5um) 2089310-03 (2 channels)
Particle size range According to the ISO 14644-1 (FS 209E) industry standard, the channel particle size ranges from 0.3um to 10um The channel size is between 0.3um and 10um, in compliance with the ISO 14644-1 (FS209E) industrial standard The channel size is between 0.5um and 5m, in compliance with ISO 14644-1 (FS209E) industrial standard 0.5um -5um according to ISO 14644-1 (FS 209E) industrial standard
Number of channels 6 3 3 2
Weight Very lightweight, only 1.5lbs (0.68KG), suitable for comfortable handheld applications.
Flow rate 2.83 lpm. Compliant with ISO 14644-1 Level 5 specification, 0.3um sample collected in 1 minute
Supports USB interface Particle counting data can be directly obtained through a computer via a USB cable or USB flash drive. No need for device drivers or software
Ethernet support Accessing granular data through common web browsers such as Windows IE, Safari, and Firefox
Display A 3.5-inch high-resolution large screen with 320 * 240 colors allows for clear and intuitive viewing of icons, making navigation easier
Display configuration Large font display, users can choose the size of the channel
Display data mode Traditional table format particle counts or trend charts are convenient for archiving particle counts
Chassis material High strength polycarbonate ABS material, very durable
Size 10.7 "x 3.9" x 2.1 ", wavy shape for easy one handed operation
The lifespan of the battery Typical models typically run for over 10 hours and have a minimum continuous operation of 5.5 hours
Data storage Can store 10000 records to meet most application scenarios
Counting efficiency 50% at 0.3 µ m; When the particle size is greater than 0.45 µ m, it is 100% (according to ISO 21501 standard) 2089310-02: 50% at 0.3 μ m; When the particle size is greater than 0.45 μ m, it is 100% (according to ISO21501) 2089310-08: 50% at 0.5 μ m; When the particle size is greater than 0.75 μ m, it is 100% (according to ISO21501) 50% at 0.5 μ m; When the particle size is greater than 0.75 μ m, it is 100% (according to ISO21501)
Zero count level 1 piece/5 minutes (according to JIS B9921 standard)
Concentration limit Compliant loss: 10% at 4000000/ft3 (compliant with ISO21501 standard)
Counting mode Original count value, N/ft3,N/m3,N/L, Cumulative mode or differential mode
Security Administrator password control (optional)
UI Language English and Japanese
Alarm User defined: Counting
Battery charging 3.5 hours
Operating environment 50 ℉~104 ℉ (10 ℃~40 ℃)/* * * up to 95%, no condensation
Storage environment 14 ° F~122 ° F (-10 ° C~50 ° C)/* * * up to 98%, no condensation
HHPC 6+Accompanying accessories
part Number 6+ 3+ 3+ 2+
2089380-01 Base, used for HHPC+6 series charging and communication x x x
230-300-1000 12 VDC power supply/charger
VP212808 Zero count filter
2089398 Zero count filter adapter
460-400-0002 6-foot USB cable
2089328-01 Carrying instrument box components, HHPC+ x
DOC026.97.80271 user's manual
Optional accessories:
part Number 6+ 3+ 3+ 2+
460-400-0005 Ethernet cable
2080732-15 High pressure diffuser 0.1 CFM and HHPC+adapter
2089380-01 Base, factory included
2089328-01 Carrying instrument box, already included at the factory






Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!