VIP member
Beckman Coulter MET ONE HHPC6+HHPC3+HHPC2+Dust Particle Analyzer Air Particle Analyzer
Beckman Coulter MET ONE HHPC6+HHPC3+HHPC2+Dust Particle Analyzer Air Particle Analyzer
Product details
Beckman Coulter MET ONE HHPC6+HHPC3+HHPC2+Dust Particle Analyzer Air Particle Counter Handheld Air Cleanliness Detector
Advantages
- Routine monitoring of clean room
A high-resolution display screen that is easy to read is fully configurable and can display the data of interest in clear large font. - Lightweight and suitable for difficult to access HEPA filter leakage scenarios
The weight of MET ONE HHPC+is only 1.5lbs, and its slim design allows for one handed operation. It is the perfect solution to easily solve the problem of filter leakage in microenvironments and workstations. - Cleanroom classification
Can quickly inspect or verify ISO 5 level (FED STD 100 level) or higher cleanrooms and controlled environments. - Visualized trends in particulate matter monitoring
Save time for on-site analysis to identify particle leakage points - Convenient data download
Data can be downloaded to an Excel spreadsheet via Ethernet using a standard browser - Using USB flash drive - Capture data
Insert the USB flash drive into MET ONE HHPC+and transfer your particle counting data directly to the computer. - Connect directly to the computer using a USB cable
Insert it like a digital camera, and your data will be displayed in Excel format. - Place your MET ONE HHPC+on the charging socket in the cleanroom
Your handheld monitor will be fully charged and ready for you to use at any time. The unique base allows the computer to retrieve data from the particle counter via Ethernet or USB cable
High tech manufacturing industry
- Semiconductor wafer fab
- Hard disk storage manufacturing industry
- Flat panel display devices
- LED (Light Emitting Diode)
- solar energy
- aerospace
- PCBA (Printed Circuit Board Assembly)
- Optical components
- Printing head manufacturing
- High precision manufacturing, MEMS (Micro Electro Mechanical Systems), MOEMS (Micro Electro Mechanical Systems)
- Used for routine monitoring of cleanrooms in the high-tech manufacturing industry
- Used for troubleshooting issues related to particle contamination in high cleanliness production environments
- Conduct spot checks at key locations
- Determine the total lead content of the filter
- The generation of needle shaped particles in process equipment or microenvironment
- Aseptic packaged food and beverage products
- Tetra Pak filling line
- hospital
- Pharmaceutical formula
- medical equipment
- As part of the Good Manufacturing Practice system, routine monitoring of controlled environments and clean rooms is conducted
- Ideal choice for ISO 5-7 levels (FED STD 100-10000 levels) control environment
- Aseptic packaged food, dairy products, and beverage products
Technical parameters: | ||||
model | 6+ | 3+ | 3+ | 2+ |
Number | 2089311-01 (6 channels) | 2089310-02 (3-channel 0.3um) | 2089310-08 (3-channel 0.5um) | 2089310-03 (2 channels) |
Particle size range | According to the ISO 14644-1 (FS 209E) industry standard, the channel particle size ranges from 0.3um to 10um | The channel size is between 0.3um and 10um, in compliance with the ISO 14644-1 (FS209E) industrial standard | The channel size is between 0.5um and 5m, in compliance with ISO 14644-1 (FS209E) industrial standard | 0.5um -5um according to ISO 14644-1 (FS 209E) industrial standard |
Number of channels | 6 | 3 | 3 | 2 |
Weight | Very lightweight, only 1.5lbs (0.68KG), suitable for comfortable handheld applications. | |||
Flow rate | 2.83 lpm. Compliant with ISO 14644-1 Level 5 specification, 0.3um sample collected in 1 minute | |||
Supports USB interface | Particle counting data can be directly obtained through a computer via a USB cable or USB flash drive. No need for device drivers or software | |||
Ethernet support | Accessing granular data through common web browsers such as Windows IE, Safari, and Firefox | |||
Display | A 3.5-inch high-resolution large screen with 320 * 240 colors allows for clear and intuitive viewing of icons, making navigation easier | |||
Display configuration | Large font display, users can choose the size of the channel | |||
Display data mode | Traditional table format particle counts or trend charts are convenient for archiving particle counts | |||
Chassis material | High strength polycarbonate ABS material, very durable | |||
Size | 10.7 "x 3.9" x 2.1 ", wavy shape for easy one handed operation | |||
The lifespan of the battery | Typical models typically run for over 10 hours and have a minimum continuous operation of 5.5 hours | |||
Data storage | Can store 10000 records to meet most application scenarios | |||
Counting efficiency | 50% at 0.3 µ m; When the particle size is greater than 0.45 µ m, it is 100% (according to ISO 21501 standard) | 2089310-02: 50% at 0.3 μ m; When the particle size is greater than 0.45 μ m, it is 100% (according to ISO21501) | 2089310-08: 50% at 0.5 μ m; When the particle size is greater than 0.75 μ m, it is 100% (according to ISO21501) | 50% at 0.5 μ m; When the particle size is greater than 0.75 μ m, it is 100% (according to ISO21501) |
Zero count level | 1 piece/5 minutes (according to JIS B9921 standard) | |||
Concentration limit | Compliant loss: 10% at 4000000/ft3 (compliant with ISO21501 standard) | |||
Counting mode | Original count value, N/ft3,N/m3,N/L, Cumulative mode or differential mode | |||
Security | Administrator password control (optional) | |||
UI Language | English and Japanese | |||
Alarm | User defined: Counting | |||
Battery charging | 3.5 hours | |||
Operating environment | 50 ℉~104 ℉ (10 ℃~40 ℃)/* * * up to 95%, no condensation | |||
Storage environment | 14 ° F~122 ° F (-10 ° C~50 ° C)/* * * up to 98%, no condensation | |||
HHPC 6+Accompanying accessories | ||||
part Number | 6+ | 3+ | 3+ | 2+ |
2089380-01 | Base, used for HHPC+6 series charging and communication | x | x | x |
230-300-1000 | 12 VDC power supply/charger | |||
VP212808 | Zero count filter | |||
2089398 | Zero count filter adapter | |||
460-400-0002 | 6-foot USB cable | |||
2089328-01 | Carrying instrument box components, HHPC+ | x | ||
DOC026.97.80271 | user's manual | |||
Optional accessories: | ||||
part Number | 6+ | 3+ | 3+ | 2+ |
460-400-0005 | Ethernet cable | |||
2080732-15 | High pressure diffuser 0.1 CFM and HHPC+adapter | |||
2089380-01 | Base, factory included | √ | √ | √ |
2089328-01 | Carrying instrument box, already included at the factory | √ | √ | √ |





Online inquiry