BZ7201E high-precision data acquisition instrument
The high-precision strain data acquisition instrument has a measurement accuracy of 0.001%, a miniaturized 6-channel effective area equivalent to two
Product details

The high-precision strain data acquisition instrument has a measurement accuracy of 0.001%, a miniaturized 6-channel effective area equivalent to two coins, digital quantity and standard bus output, and all functions of intelligent settings are completed by software, such as channel selection, function settings, parameter calibration, etc. Personalized compensation can be embedded with strain sensors to make it an integrated digital sensor. Can be applied to high-end testing scenarios such as aerospace wind tunnels.

Instrument Features
1. The high-precision data acquisition instrument achieves a measurement accuracy of 0.001% ± 35 nVP-PIt is particularly suitable for measuring static balances.
2. The chopper technology inside the instrument can stably measure the zero point with high precision; 50Hz notch technology can reduce 50Hz and its harmonics to below -120dB; Oversampling technology effectively reduces sampling noise; Digital filtering technology can filter out high-frequency interference signals outside the frequency band. Ensuring high precision and stability in measurement.
3. The high-precision data acquisition instrument consists of two parts: the host and the power supply. The small-sized host can be embedded inside the balance to directly output digital signals.
4. The high-precision data acquisition instrument can choose from 6 differential input channels connected to 6 independent strain full bridges, or 12 pseudo differential input channels connected to 12 independent strain half bridges; Program control completes functions such as automatic balancing, automatic compensation of reference voltage, debugging, calibration, etc. All information is permanently stored and not lost in case of power failure.
5. The host and computer communicate through RS485 bus, and one computer can manage multiple hosts simultaneously.
6. There are no mechanical movable parts inside the instrument (such as switches, potentiometers, etc.), and the input end is connected to the strain gauge with solder, which will not affect the reliability and long-term stability of the instrument due to factors such as oxidation and vibration.

Maximum number of channels

Differential input:8Channel. Pseudo differential input:16通道。

Maximum differential input voltage

4.4V

Maximum sampling rate

1000Hz

Minimum noise effective value

11nV

Highest noise free sampling resolution

22bit

Highest measurement accuracy

0.0005%

Maximum differential voltage input

±15.6mV(reference voltage=2V)±39mV(reference voltage=5V)

Common mode input voltage range

0.3V~4.7V

Input self-test

Input fault or disconnected software prompt

Basic error

typical value0.001%±35nVP-P

zero drift

25nV/1000hour

temperature drift

±1ppm/

output

digital quantity

Balance method

Automatic Balance

Balance range

full scale

Balance self check

Software prompt for exceeding the balance range

reference voltage

Power output reference voltage:2VDCExternal reference voltage:Simulate power supply voltage(AVDD). Choose one benchmark to output to the host

Reference voltage correction accuracy

0.001 %

Bridge arm resistance

50~10000Ω Optional

communication interface

RS485

Instrument address

1~255Factory settings address:1

Multiple online devices

1Computers can be connected simultaneouslyHosts with different addresses

power supply

Power supply: 220VAC/0.2A/50Hz.
Host power supply: Analog power supply voltage (AVDD):+5 ± 0.2VDC,
Digital supply voltage (DVDD):+5 ± 0.2VDC, analog ground (AGND) and digital ground (DGND) are not grounded together.

ambient temperature

-10~50

ambient humidity

85%

Overall dimensions

host:35×32×10mm(No socket),35×45×16mm(with socket)