Beijing Aiwantis Technology Co., Ltd
Home>Products>AvaSpec-ULS2048x64-EVO
Product Groups
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
  • Address
    Room 120912102609, Building E, Youlehui, Wangjingyuan, Chaoyang District, Beijing
Contact Now
AvaSpec-ULS2048x64-EVO
In addition to the refrigerated spectrometer AvaSpec-ULS2048x64TEC-EVO with a low-noise detector, Avantes also offers a more affordable non refrigerat
Product details
AvaSpec-ULS2048x64-EVO

In addition to the refrigerated spectrometer AvaSpec-ULS2048x64TEC-EVO with a low-noise detector, Avantes also offers a more affordable non refrigerated spectrometer AvaSpec-ULS2048x64-EVO. With its standard 2048x64 back illuminated detector, this spectrometer is highly suitable for applications with low sensitivity requirements in the UV and NIR bands. For applications that require an integration time of less than 2 seconds, refrigeration is usually not necessary. This non cooled spectrometer AvaSpec-ULS2048x64-EVO has a high UV response and a 0.9 mm high detector, making it very suitable for application in the DOAS field.

The options include a second-order diffraction filter and an inflation port for deep ultraviolet measurement. AvaSpec-ULS2048x64-EVO has multiple slit sizes and gratings, and can be configured with SMA or FC/PC fiber optic connectors. AvaSpec-ULS2048x64-EVO uses AS-7010 circuit board, providing USB3 (10 times faster than USB2), Gigabit Ethernet, and better signal processing capabilities. By connecting to a PC via USB3 or Ethernet, the data transfer speed can reach 2ms/scan. The instrument comes with AvaSoft Basic software, USB cable, and operation manual.

technical data
optical table ULS, symmetrical Czerny Turner optical path, focal length 75 mm
wavelength range 200-1160nm
resolution 0.09-20 nm, depending on spectrometer configuration
stray <1%, depending on the grating
sensitivity 650,000(Count/µ W, integration time per millisecond)
detector Back illuminated CCD detector, 2048x64 pixels (height: 0.89 nm)
Signal to Noise Ratio 450:1
ad converter 16 bit, 1.33 MHz
pointstime 2.4 milliseconds -25 seconds
communication interface USB 3.0 high-speed, 5 Gbps, Gigabit Ethernet 1 Gbps
Sample Rate 2.44 ms/scan
Readout Noise 7.5 cnt RMS

Data transmission speed

2.44 ms/scan(USB3)

Digital I/O interface HD-26 connector, 2 analog inputs, 2 analog outputs, 13 digital bidirectional, trigger, sync, strobe, laser
Power requirements Default USB3 power supply, 885 mAOr 12 VDC, 420 mA
Size, weight 175 x 127 x 44.5 millimeters (single channel), 1180 grams


Grating selection table
Application scope Available wavelengths Spectral range (nm) Number of grating lines/mm Sparkling wavelength (nm) Grating model
UV/VIS/NIR 200-1160** 960** 300 300 UA
UV/VIS/NIR 200-1100** 900** 300 300/1000 UNA-DB
UV/VIS 200-850 520 600 300 UB
UV 200-750 250-220* 1200 250 UC
UV 200-650 165-145* 1800 UV UD
UV 200-580 115-70* 2400 UV UE
UV 200-400 70-45* 3600 UV UF
UV/VIS 250-850 520 600 400 BB
VIS/NIR 300-1160** 860** 300 500 VA
VIS 360-1000 500 600 500 VB
VIS 300-800 250-200* 1200 500 VC
VIS 350-750 145-100* 1800 500 VD
VIS 350-640 75-50* 2400 VIS VE
NIR 500-1050 500 600 750 NB
NIR 500-1050 220-150* 1200 750 NC
NIR 600-1160 350-300 830 800 SI
NIR 600-1160** 560** 300 1000 IA
NIR 600-1160 500 600 1000 IB

*Depends on the starting wavelength of the grating; The higher the wavelength, the greater the dispersion, and the smaller the selection range.
**Please note that not all 2048 pixels will be used for the available range

Resolution Table of Spectrometer
Slit width (μ m)
Grating (lines/mm) 10 25 50 100 200 500
300 1.40 1.50 2.5 4.8 9.2 21.3
600 0.70-0.80* 0.75-0.85* 1.2 2.4 4.6 10.8
830 0.42-0.48* 0.50-0.58* 0.93 1.7 3.4 8.5
1200 0.25-0.31* 0.37-0.43* 0.52-0.66* 1.1 2.3 5.4
1800 0.17-0.21* 0.26-0.32* 0.34-0.42* 0.8 1.6 3.6
2400 0.12-0.18* 0.18-0.24* 0.26-0.34* 0.44-0.64* 1.1 2.7
3600 0.09-0.12* 0.11-0.15* 0.19 0.4 0.8 1.8

*Depends on the starting wavelength of the grating; The higher the wavelength, the greater the dispersion, and the smaller the selection range.

ordering information
AvaSpec-ULS2048x64-EVO 75mm AvaBench, 2048x64 pixel backlit CCD detector, USB powered, high-speed USB3 and ETH interface. AvaSoft Basic, USB interface cable.
Specify grating, wavelength range, and options.
PS-12V/1.0A The external power required to run in ETH mode.


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!