Autocorrelation instrument
A. Femtosecond scanning autocorrelation instrument
AA-20DD
Product Features:
·Pulse width range 10-300000 fs
·Scanning frequency 0.1-20Hz
·Linear distortion<1%
·Software, USB connection
·Total Reflection Optical System
·Position measurement
·Fringe resolved autocorrelation function
·Smooth movement
·Optional fiber optic input
Application:
Pulse width measurement of femtosecond oscillator
Detailed parameters:
Wavelength Range,nm |
450-700 (AA-20DDV) |
Pulse width range,fs |
20-6000 * * (default); |
Input repetition rate |
>10 kHz (default); |
Standard sensitivity |
100 mW2 |
Input polarization,linear |
horizontal (vertical upon request) |
Scanning frequency,Hz |
0.1-20 |
Linear distortion,% |
<1% |
Collinearity(Interference and Intensity)Self related |
yes |
PCConnector |
USB |
Supporting equipment |
PC with Windows OS or oscilloscope |
Fiber optic input(Optional) |
FC/PC or FC/APC (other types are optional) |
Signal source and detector |
Two Photons in Semiconductor Conductivity |
size,mm |
132x129x117 (optical unit) |
*AA-20DD can cover a range selected by customers, or two separate ranges (i.e. 450-1300 or 700-2000), three ranges, by replacing optics and detectors
**Pulse width available from 10fs
B. Multi photon microscope scanning autocorrelation instrument
Product Features:
·Input pulse width 20-12000fs
·External and internal detectors
·Scanning frequency 0.1-20Hz
·Linear distortion<1%
·USB connection
·Total Reflection Optical System
·Position measurement
·Fringe resolved autocorrelation function
·Smooth movement
·Bypass function
Application:
·Multiphoton microscope
·Femtosecond pulse width measurement of pulses before and after optical dispersion in microscopes or other optical devices
·Comparison of dispersion values to determine the dispersion values of various optical components
Detailed parameters:
Wavelength Range,nm |
450-700 (AA-MV) |
Number of detectors |
Two (including one external) |
Pulse width range,fs |
20-12000 |
Output repetition frequency |
>10 kHz |
sensitivity |
100 mW2 |
Input polarization,linear |
Horizontal (vertical optional) |
Scanning frequency,Hz |
0.1-20 |
Linear distortion,% |
<1% |
Collinearity(Interference and Intensity)Self related |
yes |
PCconnect |
USB |
Supporting equipment |
PC with Windows OS or oscilloscope |
Fiber optic input(Optional) |
FC/PC or FC/APC (other types are optional) |
Signal source and detector |
Two Photons in Semiconductor Conductivity |
size,mm |
210x164x132 (optical unit) |
C. Scanning Autocorrelated Instrument IR
Product Features:
·Pulse width range 50fs-250ps
·Wavelength range 450-3000nm (with 3-5.5 5.5-7 7-10um available)
·USB connection
Application:
·Femtosecond and Picosecond Pulse Width Measurement
·Development of Novel Ultrafast Fiber Laser
·OPA pulse width measurement
Detailed parameters:
Input wavelength range |
450-700 nm |
Input pulse widthvs.Input pulse energy |
Full: 50 fs - 250 ps |
Input pulse repetition rate |
10 Hz - 100 MHz |
Input polarization,linear |
horizontal |
time resolution,fs |
8.3 fs (at input duration 50-100 fs) |
Full scanning range |
850 ps |
Supporting equipment |
PC with USB, Windows OS |
Power supply requirements |
220/110 V AC; 50/60 Hz ±10% |
size,mm |
Optical unit: 450x250x210 |
D. Single shot femtosecond autocorrelation instrument
Product Features:
·CCD detector
·Sensitivity
·Including Labview driver
Application:
·Single shot femtosecond pulse width measurement
·Complex experimental automation device
Detailed parameters:
Wavelength Range,nm |
700-1300 or 1300-2000 (other wavelength ranges are optional) |
|
Pulse width range,fs |
15-200 |
200 - 2000 |
Input pulse energy,nJ |
>1000 (1-10 Hz) |
|
Input repetition rate,Hz |
1-10 Hz in single shot mode |
|
Input polarization,linear |
horizontal (vertical by request) |
|
handle |
USB controller |
|
size(LxWxH),mm |
156x120x70 |