Shenzhen Xiangzhuyuan Industrial Co., Ltd
Home>Products>Analyzer accessories C79 series
Analyzer accessories C79 series
Analyzer accessories C79 series
Product details

To meet the needs of users, Shenzhen Xiangzhuyuan Industrial Co., Ltd. has a large number of spare parts for ULTRAMAT23 analyzers, all of which are original imported brand new products. We can also provide analyzer maintenance services and have a large inventory of commonly used ones. If you have advantages, please feel free to inquire and purchase..

Part Number Name Order Number Remarks

Oxygen sensor C79451-A3458-B55

11 Flow meter C79402-Z560-T1

Front of condensate tank C79451-A3008-B43

12.1 Filter C74127-Z1211-A1 is located in the condensate tank

111

Electronic device

ULTRAMAT 23 gas analyzer

C79000-B5276-C216-01

112

Part Number Name Order Number Remarks

3 LCD models C79451-A3494-B16

4 keyboards C79451-A3492-B605

5-plug filter W75041-E5602-K2

5.1 Fuse W79054-L1010-T630 230V/230V; T0,63/250V see behind the instrument

5.2 Fuse W79054-L1011-T125

100V/120V; T1, 25/250V at the back of the instrument

Power switch W75050-T1201-U101

113

pump

ULTRAMAT 23 gas analyzer

C79000-B5276-C216-01

114

Part Number Name Order Number Remarks

8.1 Sample air pump C79451-A3494-B10 50Hz

8.2 Sample air pump C79451-A3494-B11 60Hz

8.3 Set gasket C79402-Z666-E20 for sample air pump

Nos8.1 and 8.2

Part Number Name Order Number Remarks

2 *) Motherboard C79451-A3494-D501

Motherboard and firmware;

German/English/French/Spanish/Italian

2.1 *) Motherboard C79451-A3492-B601 without firmware

2.2 Firmware (FlashPROM) C79451-A3494-S501

German/English/French/Spanish/Italian

3.1 Additional electronic components DP A5E PROFIBUS DP

3.2 Additional electronic components PA A5E PROFIBUS PA

3.3 Firmware (PROFIBUS) A5E

German/English/French/Spanish/Italian

When replacing them, a new temperature compensation is required.

115

Summary Table of Analysis Components

ULTRAMAT 23 gas analyzer

C79000-B5276-C216-01

116

Analyze components

ULTRAMAT 23 gas analyzer

C79000-B5276-C216-01

117

7MB2335-

Part Number Name Order Number Remarks

1 *) IR source C79451-A3468-B206

2.1 Isolation block C79451-A3468-C20

2.2 Filter C75285-Z1491-C5 for NO * *)

2.2 Filter C79285-Z1302-A4 for SO2 * *

2.2 Filter C79285-Z1491-C2 for C2H4

3 *) Chopper C79451-A3468-B515

Plate C79451-A3468-B513 with bolts and windows

5.1 O-ring C71121-Z100-A99

5 Sampling units with O-ring seals

C79451-A3468-B231 sampling unit length: 180mm

5 Sampling units with O-ring seals

C79451-A3468-B232 sampling unit length: 90mm

5 Sampling units with O-ring seals

C79451-A3468-B233 Sampling unit length: 60mm

5 Sampling units with O-ring seals

C79451-A3468-B234 Sampling unit length: 20mm

5 Sampling Unit C79451-A3468-B235 Sampling Unit Length: 6mm

5 Sampling Unit C79451-A3468-B236 Sampling Unit Length: 2mm

Gas filter C79451-A3458-B500 for CO

Gas filter C79451-A3458-B508 for SO2

Gas filter C79451-A3458-B541 for CO2, minimum range<5%

Gas filter C79451-A3458-B542 is used for CH4, with a minimum range of<2%

*When replacing them, a new temperature compensation is required.

**After replacing them, please detect the interference of water vapor.

118

7MB2335-

Part Number Name Order Number Remarks

Detector C79451-A3468-B525 is used for CO, with a minimum range of<5%

7 *) Detector C79451-A3468-B528 for CO, minimum range<5%

Detector C79451-A3468-B536 is used for CO2 with a minimum range of<1000vpm

Detector C79451-A3468-B526 is used for CO2 with a minimum range of<1000vpm

Detector C79451-A3468-B527 is used for CH4, with a minimum range of<20%

Detector C79451-A3468-B529 is used for CH4, with a minimum range of 20%

7 *) Detector C79451-A3468-B537 for C2H4

7 *) Detector C79451-A3468-B520 for NO

7 *) Detector C79451-A3468-B521 for SO2

7 *) Detector C79451-A3468-B535 for R22

*When replacing them, a new temperature compensation is required.

Shenzhen Xiangzhuyuan Industrial Co., Ltd. mainly produces Siemens series, EBM fans, Xerox fans, Heidenhain encoders, as well as various well-known industrial control new products in Europe. Please feel free to contact me at any time if you need.

Commonly used items are available in large quantities in stock, and if there are advantages, please feel free to inquire. Our company will provide you with the best products and the best pre-sales and after-sales services.QQ: / /

119

Analyze components

ULTRAMAT 23 gas analyzer

C79000-B5276-C216-01

120

7MB2337-

Part Number Name Order Number Remarks

1 *) IR source C79451-A3468-B206

2.1 Isolation block C79451-A3468-C20

2.2 Filter C75285-Z1491-C5 for NO * *)

2.2 Filter C79285-Z1302-A4 for SO2 * *

2.2 Filter C79285-Z1491-C2 for C2H4

3 *) Chopper C79451-A3468-B516

Plate C79451-A3468-B514 with bolts and windows

5.1 O-ring C71121-Z100-A99

5 Sampling units with O-ring seals

C79451-A3468-B231 sampling unit length: 180mm

5 Sampling units with O-ring seals

C79451-A3468-B232 sampling unit length: 90mm

5 Sampling units with O-ring seals

C79451-A3468-B233 Sampling unit length: 60mm

5 Sampling units with O-ring seals

C79451-A3468-B234 Sampling unit length: 20mm

5 Sampling Unit C79451-A3468-B235 Sampling Unit Length: 6mm

5 Sampling Unit C79451-A3468-B236 Sampling Unit Length: 2mm

Gas filter C79451-A3458-B500 for CO

Gas filter C79451-A3458-B508 for SO2

Gas filter C79451-A3458-B541 for CO2, minimum range<5%

Gas filter C79451-A3458-B542 is used for CH4, with a minimum range of<2%

*When replacing them, a new temperature compensation is required.

**After replacing them, please detect the interference of water vapor.

121

7MB2337-

Part Number Name Order Number Remarks

7.1/7.2 *) Detector C79451-A3468-B525 for CO, minimum range<5%

7.1/7.2 *) Detector C79451-A3468-B528 for CO, minimum range<5%

7.1/7.2 *) Detector C79451-A3468-B536 for CO2, minimum range<1000vpm

7.1/7.2 *) Detector C79451-A3468-B526 for CO2, minimum range<1000vpm

7.1/7.2 *) Detector C79451-A3468-B527 for CH4, minimum range<20%

7.1/7.2 *) Detector C79451-A3468-B529 for CH4, minimum range<20%

7.1/7.2 *) Detector C79451-A3468-B537 for C2H4

7.1 *) Detector C79451-A3468-B520 for NO (channel 1)

7.2 *) Detector C79451-A3468-B522 for NO (channel 2)

7.1 *) Detector C79451-A3468-B521 for SO2 (Channel 1)

7.2 *) Detector C79451-A3468-B523 for SO2 (Channel 2)

*When replacing them, a new temperature compensation is required.

122

Analyze component 1 CO/NO

ULTRAMAT 23 gas analyzer

C79000-B5276-C216-01

123

7MB2338-. AA..-,AK..-

Part Number Name Order Number Remarks

1 *) IR source C79451-A3468-B206

3 *) Chopper C79451-A3468-B516

Plate C79451-A3468-B514 with bolts and windows

5.1 O-ring C71121-Z100-A99

5 Sampling units with O-ring seals

C79451-A3468-B231 sampling unit length: 180mm

Gas filter C79451-A3458-B500 for CO

7 *) Detector C79451-A3468-B530 for CO

8 *) Filter C79451-A3458-B103 for NO * *)

Detector C79451-A3468-B520 for NO (channel 1)

*When replacing them, a new temperature compensation is required.

**After replacing them, please detect the interference of water vapor.

124

Analyze component 1 CO/NO

ULTRAMAT 23 gas analyzer

C79000-B5276-C216-01

125

7MB2338-.AB..-

Part Number Name Order Number Remarks

1 *) IR source C79451-A3468-B206

3 *) Chopper C79451-A3468-B516

Plate C79451-A3468-B514 with bolts and windows

5.1 O-ring C71121-Z100-A99

5 Sampling units with O-ring seals

C79451-A3468-B233 Sampling unit length: 60mm

Gas filter C79451-A3458-B500 for CO

7 *) Detector C79451-A3468-B530 for CO

Filter C79451-A3458-B103 for NO * *)

Detector C79451-A3468-B520 for NO (channel 1)

*When replacing them, a new temperature compensation is required.

**After replacing them, please detect the interference of water vapor.

126

Analyze component 1 CO/NO

ULTRAMAT 23 gas analyzer

C79000-B5276-C216-01

127

7MB2338-.AC..-

Part Number Name Order Number Remarks

1 *) IR source C79451-A3468-B206

3 *) Chopper C79451-A3468-B516

Plate C79451-A3468-B514 with bolts and windows

5.1 O-ring C71121-Z100-A99

5 Sampling units with O-ring seals

C79451-A3468-B232 sampling unit length: 90mm

Gas filter C79451-A3458-B500 for CO

7 *) Detector C79451-A3468-B530 for CO

Filter C79451-A3458-B103 for NO * *)

Detector C79451-A3468-B520 for NO (channel 1)

*When replacing them, a new temperature compensation is required.

**After replacing them, please detect the interference of water vapor.

ULTRAMAT 23 gas analyzer

C79000-B5276-C216-01

128

Analyze component 1 CO/CO2+CO2/CH4

Shenzhen Xiangzhuyuan Industrial Co., Ltd. mainly produces Siemens series, EBM fans, Xerox fans, Heidenhain encoders, as well as various well-known industrial control new products in Europe. Please feel free to contact me at any time if you need.

Commonly used items are available in large quantities in stock, and if there are advantages, please feel free to inquire. Our company will provide you with the best products and the best pre-sales and after-sales services.QQ: / /

ULTRAMAT 23 gas analyzer

C79000-B5276-C216-01

129

7MB2338-

Part Number Name Order Number Remarks

1 *) IR source C79451-A3468-B206

3 *) Chopper C79451-A3468-B516

Plate C79451-A3468-B514 with bolts and windows

7MB2338-.BA..-

5 Sampling Unit C79451-A3468-B236 Sampling Unit Length: 2mm

7 *) Detector C79451-A3468-B532 for CO

9 *) Detector C79451-A3468-B526 for CO2

7MB2338-.CB..-

5 Sampling Unit C79451-A3468-B235 Sampling Unit Length: 6mm

7 *) Detector C79451-A3468-B531 for CO2

Detector C79451-A3468-B527 for CH4

*When replacing them, a new temperature compensation is required.

ULTRAMAT 23 gas analyzer

C79000-B5276-C216-01

130

Analyze component 1 CO/CO2+CO2/CH4

ULTRAMAT 23 gas analyzer

C79000-B5276-C216-01

131

7MB2338-

Part Number Name Order Number Remarks

1 *) IR source C79451-A3468-B206

3 *) Chopper C79451-A3468-B516

Plate C79451-A3468-B514 with bolts and windows

7MB2338-.BB..-

5 Sampling Unit C79451-A3468-B236 Sampling Unit Length: 2mm

7 *) Detector C79451-A3468-B532 for CO

8.1 O-ring C71121-Z100-A99

8 Sampling units with O-ring seals

C79451-A3468-B234 Sampling unit length: 20mm

9 *) Detector C79451-A3468-B526 for CO2

7MB2338-.CA..-

5 Sampling Unit C79451-A3468-B235 Sampling Unit Length: 6mm

7 *) Detector C79451-A3468-B531 for CO2

8 Sampling Unit C79451-A3468-B235 Sampling Unit Length: 6mm

Detector C79451-A3468-B527 for CH4

*When replacing them, a new temperature compensation is required.

ULTRAMAT 23 gas analyzer

C79000-B5276-C216-01

132

ULTRAMAT 23 gas analyzer

C79000-B5276-C216-01

133

Part Number Name Order Number Remarks

1 *) IR source C79451-A3468-B206

2.1 Isolation block C79451-A3468-C20

2.2 Filter C75285-Z1491-C5 for NO * *)

2.2 Filter C79285-Z1302-A4 for SO2 * *

2.2 Filter C79285-Z1491-C2 for C2H4

3 *) Chopper C79451-A3468-B516

Plate C79451-A3468-B514 with bolts and windows

5.1 O-ring C71121-Z100-A99

5 Sampling units with O-ring seals

C79451-A3468-B231 sampling unit length: 180mm

5 Sampling units with O-ring seals

C79451-A3468-B232 sampling unit length: 90mm

5 Sampling units with O-ring seals

C79451-A3468-B233 Sampling unit length: 60mm

5 Sampling units with O-ring seals

C79451-A3468-B234 Sampling unit length: 20mm

5 Sampling Unit C79451-A3468-B235 Sampling Unit Length: 6mm

5 Sampling Unit C79451-A3468-B236 Sampling Unit Length: 2mm

Gas filter C79451-A3458-B500 for CO

Gas filter C79451-A3458-B508 for SO2

Gas filter C79451-A3458-B541

For CO2, minimum amount

Cheng<5%

Gas filter C79451-A3458-B542

Used for CH4, minimum range<2%

*When replacing them, a new temperature compensation is required.

**After replacing them, please detect the interference of water vapor.

ULTRAMAT 23 gas analyzer

C79000-B5276-C216-01

134

Part Number Name Order Number Remarks

Detector C79451-A3468-B525 is used for CO, with a minimum range of<5%

Detector C79451-A3468-B528 is used for CO, with a minimum range of 3%

7 *) Detector C79451-A3468-B536 for CO2, minimum range

<1000vpm

7 *) Detector C79451-A3468-B526 for CO2, minimum range

³1000vpm

Detector C79451-A3468-B527 is used for CH4, with a minimum range of<20%

Detector C79451-A3468-B529 is used for CH4, with a minimum range of 20%

7 *) Detector C79451-A3468-B537 for C2H4

7 *) Detector C79451-A3468-B522 for NO (channel 1)

7 *) Detector C79451-A3468-B523 for SO2 channel 2)

*When replacing them, a new temperature compensation is required.

Shenzhen Xiangzhuyuan Industrial Co., Ltd. mainly produces Siemens series, EBM fans, Xerox fans, Heidenhain encoders, as well as various well-known industrial control new products in Europe. Please feel free to contact me at any time if you need.

Commonly used items are available in large quantities in stock, and if there are advantages, please feel free to inquire. Our company will provide you with the best products and the best pre-sales and after-sales services.QQ: / /

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!