Tengzhou Zhongke Spectral Analysis Instrument Co., Ltd
Home>Products>Analysis of benzyl alcohol in cosmetics by gas chromatography manufacturer
Product Groups
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    18663278921
  • Address
    No. 20, Xibeitan, Tengzhou City, Shandong Province
Contact Now
Analysis of benzyl alcohol in cosmetics by gas chromatography manufacturer
Product introduction GC-2020 gas chromatograph is mainly applicable to the determination of benzyl alcohol content in cream, milk, liquid and powder c
Product details
brand ZKP/Zhongkepu

Principle of determination of benzyl alcohol in cosmetics by gas chromatography analysisAfter extraction, the sample was separated by gas chromatography and detected by hydrogen flame ionization detector. Qualitative analysis was performed based on retention time, and quantitative analysis was performed using peak area. The content was calculated using standard curve method. The detection limit of this method is 0.0012 μ g, and the lower limit of quantification is 0.0039 μ g. If 1.0g of sample is taken, the detection concentration of benzyl alcohol by this method is 0.0012%, and the lowest quantitative concentration is 0.004%.
Instrument configuration, reagents and materials

Instrument configuration and reagents

Gas chromatograph host

GC-2020 chromatograph (FID+capillary)

1 unit

chromatographic column

FFAP quartz capillary chromatography column 30m × 0.25mm × 0.25 μ m

1 unit

data processing

Chromatography workstation

1 set

External air source

Hydrogen gas cylinder or generator

1 set

computer

Brand computer XP system

1 unit

Reagents and related equipment

Anhydrous ethanol.(Pure analysis)

Benzyl alcohol, purity ≥ 99.5%

Analytical balance: sensitivity of 0.01g

Volumetric flasks: 10ml, 100ml

Centrifuge tube with stopper scale: 10mlVortex oscillator.

Constant temperature water bath;Ultrasonic cleaning device.
Centrifuge: The speed should not be less than 5000r/min.

Injection type sample filter (organic solvent type, 0.45 μ m)

.






  


 







Gas chromatogram of benzyl alcohol standard solution

GC-2020 gas chromatographPerformance characteristics

1. Adopting320 x 240dot matrix5.7An inch large screen LCD Chinese display, real-time display of various temperatures and operating conditions, clear and intuitive content, truly realizing human-machine dialogue;
2Power on self-test, wide range self diagnostic function, can accurately determine the fault location and alarm;
3Six independent temperature controls (vaporization chamber and capillary vaporization chamber can be independently controlled), Five level program heating function;
4Overtemperature Protection function: If any circuit exceeds the set temperature, the instrument will automatically power off and sound an alarm;
5The vertical heating device of * makes sample vaporization more reliable, reduces the heat radiation generated in the vaporization chamber to the minimum, and ensures minimal temperature deviation inside the column box;
6Intelligent fuzzy control rear door opening system, automatically tracks temperature and dynamically adjusts The angle of the air door can achieve precise temperature control even near room temperature;
7Configure filling column head injection, glass lining injection, with diaphragm cleaning Functional capillary diversion/Non split injection device and capable of installing gas injectors;
8High precision dual stable gas path, capable of installing four types of detectors simultaneously;
9
Optional electronic flow pressure display system with built-in workstation device.

Temperature control indicators
1.Temperature control range: room temperature 5400 increment0.1
2.Temperature control accuracy: superior to±0.01

Program heating: Five step interval constant temperature time0999minincrement0.1minTemperature increment0.1
Heating rate:200The biggest one below40/min 200Up to the biggest20/min


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!