Detailed information of SNC2100-C2H5OH alcohol concentration meter:
SNC2100-C2H5OH alcohol concentration meterintroduce:
The online trace alcohol concentration meter and transmitter are a new generation of equipment independently developed by Fuzhan Environmental Protection Technology for continuous online detection of alcohol concentration. Due to the difference in dielectric constants of media such as water and alcohol, the proportional relationship between alcohol and water is reflected, and the concentration value of alcohol (or water) is calculated through a microcontroller. It has the advantages of simple structure, high resolution, non-contact measurement, and can work under harsh conditions such as high temperature, radiation, and strong vibration.
SNC2100-C2H5OH alcohol concentration meterscope of application:
This product can also be called an ethanol concentration tester or an ethanol concentration meter. It can be used for automatic alcohol concentration ratio in pharmaceutical factories, alcohol concentration detection in distilleries, and rapid and continuous monitoring, process control, and alarm of liquid alcohol concentration in industries such as chemical plants and building materials.
SNC2100-C2H5OH alcohol concentration meterTechnical features:
The measurement range is large and can be applied to 0 Range from 1 to 100%
Widely applicable and suitable for testing the concentration of polar to non-polar substances
Fast response speed, signal response time<5s
The detection structure is easy to adjust
Perform dual temperature compensation on the instrument for higher temperature
Durable and sturdy, not prone to scaling, adhesion, or blockage
High material compatibility and selectivity
Electrical parameters of transmitter:
Power supply: 12VDC or 24VDC
Signal transmission: standard (4-20) mA
Communication transmission: RS232 serial port or RS485
Explosion proof mark: ExiaIICT5
Technical parameters of transmitter:
Test range: 0.1% to 100%
resolving power: 0.1%
Indication error: ±0.5%
Stability of indication: Zero drift less than 0.1% within 24 hours
Repeatability of indication: less than 2% within 24 hours (refer to the repeatability calculation formula)
Instrument operating temperature (optional):- 20℃ TO 55℃
-10℃ TO 60℃
0℃ TO 80℃
Moisture content scale value: 0.01%
Work pressure: less than 0.6MPa,
Installation method: Customization can be requested by customers (flange, chuck, pipeline)
Insertion depth: 100mm (standard); selectable
Application requirement: Material mixing must be uniform.