Second hand liquid chromatograph Agilent 1100
Having flexible and versatile combination methods** System performance indicators; A graphical workstation friendly interface; The intelligent maintenance system and improved regulatory certification functions, as well as the continuous introduction of new components, enhance the analytical field of Agilent liquid chromatography.
The capillary liquid phase pump system controlled by an electronic flow control valve (EFC) has high accuracy and a wide flow rate range. The column flow rate range is 1-20ul/min; 10-100ul/min (optional)
0.001-2.5m/min (EFC closed state)
High pressure preparation pump system, unit or dual high-pressure preparation pump
Flow rate range: 0.001-100m1/min
● Flow rate range of analytical pump system:
Unit pump: 0.001-10m3/min, binary pump: 0.001-5m3/min, quaternary pump: 0.001-10m3/min
Used Agilent liquid chromatography 1100 series configuration
Used Agilent liquid chromatography 1100 series injection system
Standard manual sampler (analytical or preparation type)
● Standard automatic sampler
Sample bottle capacity: up to 100 pieces (2mlx100)
Injection volume: 0.1-100ul (0.1-1800ul) optional
● Micro disc automatic sampler
Sample bottle capacity: 2 × 96 (orifice plate), 2 × 386 (orifice plate) or 100x2ml
Injection volume: 0.1-100ul (standard part) 0.1-1500ul optional
● Micro standard automatic sampler/micro disc automatic sampler
Injection volume: 0.01-8ul (standard); 0.01-40ul (optional)
● Constant temperature standard automatic sampler/micro disc automatic sampler
Temperature range: 4-40 ℃ with adjustable step size of 1 ℃
220 type microporous plate automatic sampler - combined chemical sample management system
Sample bottle capacity: up to 12 microplates (96 well plate, 384 well plate) for various specifications of test tubes
Injection volume: 0.1-5ul; 0.1-20ul
Variable wavelength scanning ultraviolet detector (VWD) wavelength range: 190? 600nm
● Multi wavelength detector (MWD) wavelength range: 190? 950nm (dual light source)
● Diode Array Detector (DAD)
Wavelength range: 190? 950nm (dual light source)
Fluorescence detector (FID) excitation wavelength: 200-700nm; Emission wavelength: 280-900nm Spectral storage: Full spectrum
Differential Refraction Detector (RID) Temperature Control: Room Temperature+5 ℃ to 55 ℃ Built in Automatic Purging Valve and Automatic Solvent Circulation Valve
Electrochemical detector (ECD)
LC/MS quadrupole mass detector (MSD)
LC/MS ion trap mass detector (Trap MSD)
Column temperature box and deaerator components
● Column temperature range: 10 ℃ to 80 ℃ at room temperature Optional: Column switching valve
Vacuum online deaerator