Product Introduction
Low temperature tank for impact testIt is a specialized testing equipment that is matched with an impact testing machine to provide a low-temperature environment for its samples. It is used to cool the samples during low-temperature impact testing without the need for dry ice, with fast cooling speed and high temperature control accuracy. It is a new cooling method - the stacked compressor refrigeration low-temperature instrument.
Standard used: JB-5376-91 "Technical Conditions for Low Temperature Constant Temperature Bath"GB/T229-2007Method for Charpy Pendulum Impact Test of Metallic MaterialsGB/T 8363-2007The requirements for low-temperature testing equipment and temperature in the "Falling Weight Tear Test Method for Ferritic Steel" (±)1℃), as well as American and European standardsASTM E23-02a、EN10045、ISO148、ISO83All temperature control indicators specified in relevant standards.
Its biggest advantage is that it is easy to operate, safe, fast and reliable, and automatically maintains a constant temperature
When cooling, only power is needed without dry ice, with fast cooling speed, large capacity, and high temperature control accuracy.
Technical Parameter
|
Technical specifications and specifications |
AWC-30 |
AWC-40 |
AWC-60 |
AWC-80 |
||
|
Temperature range (continuously adjustable setting) |
+30~-30℃ |
+30~-40℃ |
+30~-60℃ |
+30~-80℃ |
||
|
Reduce Warm Speed up Degree |
+30~0℃ |
make an appointment1.8℃/min |
make an appointment1.8℃/min |
make an appointment1.5℃/min |
make an appointment1.5℃/min |
|
|
0~-20℃ |
make an appointment0.8℃/min |
make an appointment1.0℃/min |
make an appointment1.2℃/min |
make an appointment1.2℃/min |
||
|
-20~-40℃ |
make an appointment0.5℃/min |
make an appointment0.8℃/min |
make an appointment1.0℃/min |
make an appointment1.0℃/min |
||
|
-40~-60℃ |
|
|
make an appointment0.7℃/min |
make an appointment0.8℃/min |
||
|
-60~-80℃ |
|
|
|
make an appointment0.5℃/min |
||
|
-80~-100℃ |
|
|
|
|
||
|
precision |
﹤±0.5℃ |
|
||||
|
Cold chamber capacity |
150×150×240mm(Length x Width x Height) |
|
||||
|
Number of samples that can be loaded |
greater than60, up to a maximum of120A standard sample |
|
||||
|
Cooling medium |
Ethanol or other non freezing liquids |
|
||||
|
Dimensions (mm) |
905×510×870 |
905×510×870 |
905×510×870 |
905×510×870 |
||
|
Working power supply |
220~240V 1.0KW |
220~240V 1.0KW |
220~240V 1.5KW |
220~240V 2.0KW |
||
|
weight |
make an appointment50Kg |
make an appointment60Kg |
make an appointment100Kg |
make an appointment120Kg |
||