AEROQUAL Series 930 Fixed Gas Monitoring Instrument
Purpose: AEROQUAL Series 930 series fixed gas monitoring instrument can be used for networked monitoring of indoor gases, with built-in control and al
Product details

AEROQUAL Series 930系列固定式气体监测仪

Purpose:

The AEROQUAL Series 930 series fixed gas monitoring instrument can be used for networked monitoring of indoor gases, with built-in control and alarm outputs, a sturdy and waterproof casing, and replaceable sensors. The 930 series can be used in industrial fields including gas leak detection, health and safety production, and production process monitoring. The applicable sensors are listed in the sensor type and parameter table below.


characteristic:

High precision sampling and measurement of gases

Anti toxic and waterproof shell

Multiple output modes

Real time networking

The sensor head can be replaced

Includes computer or network acquisition software

Optional large screen LED real-time display

Optional temperature and humidity sensor and flash


Technical specifications:

power supply

12 VDC; 800 mA; The AC power converter is already included

Analog Output

4-20mA (opto-isolated), 10-30V

External signal type

Transistor output

External model function

High/Low Alarm/Control/Diagnosis

led display

optional

input

Standby switch

communication

RS485 (Aeroqual proprietary protocol)

fixed

screw

ID identity setting

1-255 can be customized, default is 1

Alarm settings

User defined

controls

User defined

The sensor is replaceable

correct

Sampling method

Built in sensor fan activity sampling

Measurement range of temperature and humidity sensor

Temperature: -40-124 ℃ Humidity: 0-100% RH (without condensation)

set up software

Computer supporting software

Housing material

Reinforced Fiber Polycarbonate | IP41&NEMA 2 Equivalent

External dimensions

180 x 110 x 90 (mm)

weight

<850g (including power adapter)

Fixed shell

Screw fixation

Product Certification

Part15 of FCC Rules

EN 50082-1: 1997

EN 50081-1: 1992

The sensor types and parameters are as follows:

gas

Sensor code

Sensor type 1

Range (ppm)

Minimum detection limit (ppm)

Factory calibration accuracy 2

Resolution (ppm)

Response time (s) 3

Operating condition 4

temperature

humidity

Ammonia (NH3)

ENG/ENG2

GSE

0-100

0.2

<±0.5ppm + 10%

0.1

120

0~40℃

15~ 90%

Carbon monoxide (CO)

ECM / ECM2

GSE

0-25

0.05

<±0.5 ppm 0-5 ppm

<±10% 5-25ppm

0.01

60

0~40℃

15~90%

Carbon monoxide (CO)

ECN / ECN2

GSE

0-100

0.2

<±1 ppm 0-10 ppm

<±10% 10-100ppm

0.1

30

0~40℃

15~90%

CO2,CO

MS1

NDIR

GSE

0-2000

0-100

10

0.2

See CD and ECN data

1

0.1

120

0~ 40℃

15~90%

CO2,CO,PID

MS2

NDIR GSE

PID

0-2000

0-1000

0-20

10

0.2

0.01

See CD, ECN and PDL data

1

0.1

0.01

120

0 ~ 40℃

15~90%

Chlorine gas (Cl2)

ECL/ECL2

GSE

0-10

0.01

<±0.02ppm + 10%

0.01

30

0~40℃

15~90%

Formaldehyde (CH2O)

EF / EF2

GSE

0-10

0.01

<±0.05 ppm 0-0.5 ppm

<±10% 0.5-10ppm

0.01

120

0~40℃

15~90%

Hydrogen (H2)

HA / HA2

GSS

0-5000

5

<±10ppm + 10%

1

30

0~40℃

10~90%

Methane (CH4)

MT / MT2

GSS

0-10000

10

<±20ppm + 15%

1

60

0~40℃

10~90%

Hydrogen sulfide (H2S)

EHS / EHS2

GSE

0-10

0.04

<±0.05 ppm 0-0.5 ppm

<±10% 0.5-10ppm

0.01

30

0~40℃

15~90%

Nitrogen dioxide (NO2)

ENW

GSE

0-1

0.005

<±0.02 ppm 0-0.2 ppm

<±10% 0.2-1 ppm

0.001

30

0 ~ 40℃

15 ~90%

NMHC

VN

GSS

0-25

0.1

<±0.1 ppm + 10%

0.1

60

0 ~ 40℃

10 ~ 90%

Ozone (O3)

OZS

GSS

0-0.05

0.001

<±0.002 ppm

0.001

240

0 ~ 40℃

10 ~90%

Ozone (O3)

OZU

GSS

0-0.15

0.001

<±0.005 ppm

0.001

60

0 ~ 40℃

10 ~90%

Ozone (O3)

OZL

GSS

0-0.5

0.001

<±0.008 ppm 0-0.1 ppm

<±10% 0.1-0.5 ppm

0.001

60

0 ~ 40℃

10 ~90%

Ozone (O3)

EOZ

GSE

0-10

0.01

<±0.01 ppm + 7.5%

0.01

5

0 ~ 40℃

15 ~90%

Sulfur dioxide (SO2)

ESO

GSE

0-10

0.04

<±0.05 ppm 0-0.5 ppm

<±10% 0.5-10ppm

0.01

60

0 ~ 40℃

15~90%

Sulfur dioxide (SO2)

ESP

GSE

0-100

0.4

<±0.5 ppm 0-5 ppm

<±10% 5-100ppm

0.1

30

0~40℃

15~90%

VOC

VM

GSS

0-25

0.1

<±0.1 ppm + 10%

0.1

60

0~40℃

10~90%

VOC

PDL

PID

0-20

0.01

<±0.02ppm + 10%

0.01

30

0~40℃

0~95%

VOC

PDH

PID

0-1000

0.1

<±0.2ppm + 10%

0.1

30

0~40℃

0~95%


Attention:

1. Sensor types: Gas sensitive semiconductor (GSS), Gas sensitive electrochemistry (GSE), Non dispersive infrared (NDIR), photoionization detector (PID)

2. The accuracy is valid for the conditions described in the calibration certificate, excluding gas tolerance correction, and the relative error of the reading is%.

3. The response time is the time (T90) when the reaction to a step change in gas concentration reaches 90% of the final reading. The actual response time will vary depending on gas exchange factors and concentration gradients.

4. The performance of the sensor will decrease beyond the described conditions to avoid condensation and damage to the sensor. The sensor will exhibit temperature and humidity interference, which will affect accuracy. Additional shell protection will expand the operating environment conditions, and the contact point will obtain further understanding from the group. Note that sensor design is intended to operate under conditions equivalent to the ambient air oxygen level.

5. Not all sensors can be used in conjunction with the 200, 300, and 500 series when in water and dust-proof enclosures (HH ENC). Please contact DianDian Technology for specific application suggestions.


Place of Origin:New Zealand