Purpose:
AEROQUAL Series 300 intelligent portable gas detector can be used in fields such as atmospheric environment monitoring and environmental research Superior cost-effectiveness, suitable for both outdoor and indoor use.
Characteristics:
Easy to use, easy to maintain, wide range of applications
The sensor is replaceable
Lithium batteries can be directly replaced on site (can be used for about 8 hours)
Minimum, maximum, and average readings
Zero degree calibration, gain adjustment
Alarm for high or low values
Analog output (0-5V)
Environmental gas sensor:
Gases suitable for field environmental monitoring: anchor carbon monoxide, carbon dioxide, hydrogen sulfide, nitrogen dioxide, non methane hydrocarbons, ozone
Gases suitable for indoor monitoring: carbon monoxide, carbon dioxide, ozone
Gases suitable for monitoring in the field of industrial safety: ammonia, carbon monoxide, carbon dioxide, hydrogen, hydrogen sulfide, methane, ozone, carbon tetrachloride, sulfur dioxide, volatile organic compounds
Technical specifications:
Measurement unit |
Ppm or mg/m3 | Temperature: ℃ | Humidity:% RH |
Reading function |
Instantaneous, minimum, maximum, average |
sensor |
Removable/replaceable pre calibrated sensors |
Display screen status display |
Battery level, sensor, backup |
calibration |
Zero value calibration, gain calibration |
output signal |
0-5V signal output |
power supply |
12VDC (power adapter, charging power supply 12VDC, 800mA) |
Rechargeable Battery |
Lithium battery 12V DC 2700 mA/h |
audible alarm |
High and low alarms can be set |
Housing material |
PC and ABS materials, IP20 or NEMA 1 protection level |
External dimensions |
195x122x54(mm); (with sensor head) |
weight |
<460g |
work environment |
Temperature: 5-45 ℃ Humidity: 0-95% RH (without condensation) |
Product Certification |
Part15 of FCC Rules EN50082-1:1997 EN50081-1:1992 |
Measurement range of temperature and humidity sensor |
Temperature: -40-124 ℃ Humidity: 0-100% RH (without condensation) |
The sensor types and parameters are as follows:
gas |
Sensor code |
Sensor type 1 |
Range (ppm) |
Minimum detection limit (ppm) |
Factory calibration accuracy 2 |
Resolution (ppm) |
Response time (s) 3 |
Operating condition 4 |
|
temperature |
humidity |
||||||||
Ammonia (NH3) |
NH/NH2 |
GSS |
0-1000 |
2 |
<±5 ppm +15% |
1 |
30 |
0~40℃ |
10~90% |
Ammonia (NH3) |
ENG/ENG2 |
GSE |
0-100 |
0.2 |
<±0.5ppm + 10% |
0.1 |
120 |
0~40℃ |
15~ 90% |
Carbon monoxide (CO) |
ECM / ECM2 |
GSE |
0-25 |
0.05 |
<±0.5 ppm 0-5 ppm <±10% 5-25ppm |
0.01 |
60 |
0~40℃ |
15~90% |
Carbon monoxide (CO) |
ECN / ECN2 |
GSE |
0-100 |
0.2 |
<±1 ppm 0-10 ppm <±10% 10-100ppm |
0.1 |
30 |
0~40℃ |
15~90% |
Carbon monoxide (CO) |
SH CO / SH CO2 |
GSE |
0-1000 |
1 |
<±2ppm + 15% |
1 |
30 |
0~40℃ |
10~95% |
Carbon dioxide (CO2) |
CD |
NDIR |
0-2000 |
10 |
<±10ppm + 5% |
1 |
120 |
0~40℃ |
10~95% |
Carbon dioxide (CO2) |
CE |
NDIR |
0-5000 |
20 |
<±20ppm + 5% |
1 |
120 |
0~40℃ |
10~95% |
CO2,CO |
MS1 |
NDIR GSE |
0-2000 0-100 |
10 0.2 |
See CD and ECN data |
1 0.1 |
120 |
0~ 40℃ |
15~90% |
CO2,CO,PID |
MS2 |
NDIR GSE PID |
0-2000 0-1000 0-20 |
10 0.2 0.01 |
See CD, ECN and PDL data |
1 0.1 0.01 |
120 |
0 ~ 40℃ |
15~90% |
Chlorine gas (Cl2) |
ECL/ECL2 |
GSE |
0-10 |
0.01 |
<±0.02ppm + 10% |
0.01 |
30 |
0~40℃ |
15~90% |
Formaldehyde (CH2O) |
EF / EF2 |
GSE |
0-10 |
0.01 |
<±0.05 ppm 0-0.5 ppm <±10% 0.5-10ppm |
0.01 |
120 |
0~40℃ |
15~90% |
Hydrogen (H2) |
HA / HA2 |
GSS |
0-5000 |
5 |
<±10ppm + 10% |
1 |
30 |
0~40℃ |
10~90% |
Methane (CH4) |
MT / MT2 |
GSS |
0-10000 |
10 |
<±20ppm + 15% |
1 |
60 |
0~40℃ |
10~90% |
Hydrogen sulfide (H2S) |
EHS / EHS2 |
GSE |
0-10 |
0.04 |
<±0.05 ppm 0-0.5 ppm <±10% 0.5-10ppm |
0.01 |
30 |
0~40℃ |
15~90% |
Hydrogen sulfide (H2S) |
EHT / EHT2 |
GSE |
0-100 |
0.4 |
<±0.5 ppm 0-5 ppm <±10% 5-100ppm |
0.1 |
30 |
0~40℃ |
15~90% |
Nitrogen dioxide (NO2) |
ENW |
GSE |
0-1 |
0.005 |
<±0.02 ppm 0-0.2 ppm <±10% 0.2-1 ppm |
0.001 |
30 |
0 ~ 40℃ |
15 ~90% |
NMHC |
VN |
GSS |
0-25 |
0.1 |
<±0.1 ppm + 10% |
0.1 |
60 |
0 ~ 40℃ |
10 ~ 90% |
Ozone (O3) |
OZS |
GSS |
0-0.05 |
0.001 |
<±0.002 ppm |
0.001 |
240 |
0 ~ 40℃ |
10 ~90% |
Ozone (O3) |
OZU |
GSS |
0-0.15 |
0.001 |
<±0.005 ppm |
0.001 |
60 |
0 ~ 40℃ |
10 ~90% |
Ozone (O3) |
OZL |
GSS |
0-0.5 |
0.001 |
<±0.008 ppm 0-0.1 ppm <±10% 0.1-0.5 ppm |
0.001 |
60 |
0 ~ 40℃ |
10 ~90% |
Ozone (O3) |
EOZ |
GSE |
0-10 |
0.01 |
<±0.01 ppm + 7.5% |
0.01 |
5 |
0 ~ 40℃ |
15 ~90% |
Perchloroethylene (C2Cl4) |
PE |
GSS |
0-200 |
1 |
<±5 ppm 0-50 ppm <±10% 50-200 ppm |
1 |
30 |
0 ~ 40℃ |
10 ~90% |
Sulfur dioxide (SO2) |
ESO |
GSE |
0-10 |
0.04 |
<±0.05 ppm 0-0.5 ppm <±10% 0.5-10ppm |
0.01 |
60 |
0 ~ 40℃ |
15~90% |
Sulfur dioxide (SO2) |
ESP |
GSE |
0-100 |
0.4 |
<±0.5 ppm 0-5 ppm <±10% 5-100ppm |
0.1 |
30 |
0~40℃ |
15~90% |
VOC |
VM |
GSS |
0-25 |
0.1 |
<±0.1 ppm + 10% |
0.1 |
60 |
0~40℃ |
10~90% |
VOC |
VP |
GSS |
0-500 |
1 |
<±5ppm + 10% |
1 |
30 |
0~40℃ |
10 to 90% |
VOC |
PDL |
PID |
0-20 |
0.01 |
<±0.02ppm + 10% |
0.01 |
30 |
0~40℃ |
0~95% |
VOC |
PDH |
PID |
0-1000 |
0.1 |
<±0.2ppm + 10% |
0.1 |
30 |
0~40℃ |
0~95% |
Attention:
1. Sensor types: Gas sensitive semiconductor (GSS), Gas sensitive electrochemistry (GSE), Non dispersive infrared (NDIR), photoionization detector (PID)
2. The accuracy is valid for the conditions described in the calibration certificate, excluding gas tolerance correction, and the relative error of the reading is%. The response time is the time (T90) when the reaction to a step change in gas concentration reaches 90% of the final reading. The actual response time will vary depending on gas exchange factors and concentration gradients.
3. The performance of the sensor will decrease beyond the described conditions to avoid condensation and damage to the sensor. The sensor will exhibit temperature and humidity interference, which will affect accuracy. Additional shell protection will expand the operating environment conditions, and contact points will gain further understanding of technology. Note that sensor design is intended to operate under conditions equivalent to the ambient air oxygen level.
4. Not all sensors can be used in conjunction with the 200, 300, and 500 series when in water and dust-proof enclosures (HH ENC). Please contact DianDian Technology for specific application suggestions.
The optional accessories are as follows:
Place of Origin:New Zealand