The 915KF Ti Touch Elf Generation is an integrated Karl Fischer titration instrument launched by Swiss company Wanton for daily water content analysis
Product details

915KF Ti-TouchThe Elf Generation is an all-in-one Karl Fischer titration instrument launched by Swiss company Wanton for daily water content analysis. haveIpolMode (polarization current))andUpolpattern(Polarization voltage)Two modes are integrated, including a dropper, a dropper driver, a stirrer, a titration tank, and an operation panel. The overall structure is compact and convenient, saving you valuable laboratory space.

Main functions and features:

?High system integration, simple and stylish appearance design

?Duo SiTM DosinoLiquid addition unit technology ensures user safety during use

?Can be expanded to dual channel water titration

?UDisk storage anti-counterfeitingPDFExperimental report, network transmission

?Multiple conversational languages including Chinese

Directly connect to the sample processor

connect 814 and 815Sample processor for batch analysis of sample water content determination

Paperless office,PDFreport

Can generate anti-counterfeiting measuresPDFExperimental report and stored inUSBFashionable and environmentally friendly in storage or network computers

Store or print data without the need for a computer

USBThe interface can be connected to a printer,USBMemory or barcode reader

Personalized touch screen, quick access to experimental methods

Can be created on the touch screen 14A shortcut icon to directly call methods for experimentation

Plug and play

All instrument accessories can be automatically recognized by the host and are ready for use at any time

Directly connect to the network without the need for a computerLIMSsystem

Can be accessed online orLIMSDirectly store experimental methods and results in the system

2individualMSBInterface, expandable to dual channel moisture titration

2individualMSBInterface(Wan Tong serial port)Can be used for connection

2individualmanythinkingTMDosinoLiquid addition unit or805 DosimatLiquid dispenser

2A magnetic stirrer or spiral stirrer

No disassembly requiredzeroContact and replace reagents

Obtaining a patented designmanythinkingTMDosinoThe liquid addition unit technology makes the replacement of Karl Fischer reagent more convenient and avoids contact with toxic and harmful reagents

KFIcon real-time display of device operating status

On the touch screenKFIcon, real-time display of whether the device is in pre titration state or sample preparation state

tiBase Data processing software to achieve comprehensive work

Store the experimental results inUSBIn storage or network computers, it can be imported into tiBase Data management in data processing software

«Safe stop volume»Prevent solution overflow from the titration tank

We are concerned about laboratory safety and strive to provide you with security guarantees. Assuming that due to electrode connection issues or excessive moisture in the titration cell, Karl Fischer reagent is continuously added to the titration cell, parameters«Safe stop volume»By defining the pre titration time and volume, it is possible to prevent the overflow of too much solution in the titration cell and automatically stop the addition of Karl Fischer reagent

Tap the button to empty and add reagents

The device is equipped with a built-in suction and discharge pump system, allowing you to simply press a button without opening the titration cup to empty the waste liquid and add solvent

Swiss WantongThe Ti Touch series integrated titrator won the 2011 Good Reader Award from Laboratory Equipment in the United States.


technical parameter

measureQuantity resolution

0.1 mv / 0.1μA

Measurement accuracy

±0.2 mV

Error in adding liquid to burette (10mL)

± 20 μ L (0.2%, better than ISO/EN/DIN standard requirement of 0.3%)

Moisture measurement range

10 ppm to 100%

Resolution of burette liquid addition

1/10000 or 1/20000 (optional)

Dialogue language:

Chinese, English, German, Spanish, French

MEAS measurement mode, measuring Ipol and Upol, and temperature T/° C

Yes

Capacity based KF titration, automatic equilibrium

Yes

Blender, titration table

Built in magnetic stirring

Additionally, it is possible to add

1 x 801 magnetic stirring or

1 x 802 spiral stirring or

1 x 803 suction and discharge titration table

Intelligent exchange unit with data chip/Dosino dosing unit

Up to 2 x Dosino dosing units or 2 x 805 Dosimat dispensers

Built in diaphragm pump

Yes

MSB interface (Wan Tong serial port)

2, used to connect the Dosino dosing unit or mixer of Dosino TM

Operation method

touch screen

Real time titration curve display - touch screen (90mm x 120mm color LCD screen)

Yes

Built in Ipol and Upol polarization interfaces

Yes

Connect the network port directly to the network for data acquisition or printing on the network printer

Yes

Sample processor

1 USB controlled sample processor

Temperature probe

Pt1000 or NTC

USB Memory Storage Experimental Method, Results, and PDF Report

Yes

Method and sample information storage, result storage database

Yes

Anti counterfeiting PDF experimental report

Yes

Balance, printer, PC, PC keyboard, barcode reader

Through two USB interfaces,

RS-232/USB control box (optional phase)

Callable shortcut icons

14 (per user)





Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!