VIP member
8712E on-site installation electromagnetic flowmeter
Specification accuracy: It has a volume flow accuracy of up to ± 0.15 at a flow range ratio of 13:1, and a volume flow accuracy of ± 0.25% at a flow r
Product details
Specifications
Accuracy: It has a volumetric flow accuracy of up to ± 0.15 at a flow range ratio of 13:1, and a volumetric flow accuracy of ± 0.25% at a flow range ratio of 40:1
Diagnosis: on-site instrument calibration, grounding/wiring fault detection, high process noise detection, adjustable air tube detection, transmitter fault detection, sensor fault detection, electrode coating detection
Compatibility: All sensors manufactured by Rosemount: 8705, 8711, 8721, 8707. The universal function makes the 8700 series transmitter compatible with sensors powered by AC and DC power from other manufacturers.
Power supply: 90-250 VAC, 50-60 Hz or 12-42 VDC
Power consumption: 15 W maximum - DC
40 VA maximum - AC
Shell protection level: 8732E: 4x type, IEC 60529, IP66
8712E: 4x type, IP66
Function
Intelligent instrument self calibration, continuously monitoring the operation and performance of the instrument without interrupting the production process
Dual chamber transmitter housing to prevent moisture from entering
Advanced digital signal processing to improve process management
High process noise diagnosis and optional coil drive frequency options to optimize control of noise applications
Adjustable air traffic control detection can minimize problems and incorrect readings when the pipeline is empty
Grounding and wiring error detection and diagnosis can quickly verify the integrity of the installation
Equipped with an optical configuration switch, there is no need to remove the cover, simplifying adjustment operations in hazardous environments
Universal transmitter capability helps reduce inventory and ensure interface consistency with electromagnetic flowmeter sensors