This product is a light source device used for evaluating and adjusting cameras and still cameras. You can see the image of flickering due to the use
Product details

3nh or DNP Standard Light Box 3nh&DNP Standard Color Viewer

This product is a light source device used for evaluating and adjusting cameras and still cameras.
You can see the image of flickering due to the use of high-frequency fluorescent lamp lighting method.


method:

Light source: DNP standard color viewer oil lamp
(Special fluorescent tube 10W x 4 for use)
Power Supply: AC100v50,60Hz
Lighting method: High frequency lighting method 20KHz
Color performance: Evaluate the color performance of each color with a score of 90 or above
Color temperature: (measured by Minolta CL-200)
Operating temperature: 10-40 ° C
Humidity usage: below 80% (condensation is not a problem)
External dimensions: 375W×365H×165D m/m
Brightness dimension: 250W×190H m/m
Chart size: 320W×290H m/m
Power consumption: 80W
Weight: 6.5kg/7.5kg
Due to the differences in brightness characteristics of the fluorescent oil lamp included in the viewer




instructions

【1】 Before use

Power supply: AC power supply 100v, 50Hz, 60Hz shared
Light source: DNP standard color viewer oil lamp 10W x 4 pieces
Power consumption: 80W

【2】 Use

(1) Insert the AC100v socket into the power code plug.
※ Attention: Please do not connect power sources other than AC100V.
When using it overseas, I will definitely ask you to use the transformer.
If it becomes a mistake to connect a power source other than AC100V, it will be burned out by installing an internal transformer.
(2) Turn on the power switch.
(3) After being lit with an oil lamp at room temperature (20 ℃), it remains stable for 15-20 minutes.
(4) When the oil lamp is not lit, request confirmation from the street electrical security personnel of other projects.
(5) When the shin king phenomenon of the oil lamp occurred, fix it and turn on the power switch 3-4 times, OFF。

【3】 When the oil lamp is not lit

Please confirm with the electrical security personnel.
(1) Connect current to socket AC100V.
(2) Insert the socket into the viewer's plug.
(3) The power switch of the viewer is turned on.

When the viewer's oil lamp is not on, consider something like the following

(1) When two oil lamps were lit, the fuse on one side of the transformer was melting.
(2) When the four oil lamps are not lit, the fuses of each of the two transformers are melting.
※ Attention: This occurs when powered on other than AC100v as mentioned in (1) and (2) above. The internal burnout of this transformer is the cause.
The exchange of transformers becomes necessary.

【4】 Exchange and cleaning with oil lamps

Place the viewer on a flat table (top) and remove the power code from the socket.
Uninstall in the following order.
(1) Loosen the two coin screws on the upper frame.
(2) If you lift the coin screw on the upper frame 50-60mm with both hands and push it forward, the upper frame will deviate from the solid.
(3) Remove the glass plate and acrylic plate.
Attention: Please be careful with your hands and fingers as the glass panel may be broken.
(Please pay attention to the edge of the board, especially when not wiping with your fingers.)

■ Oil lamp exchange
(1) Also, when one year passes, it lights up for 2000 hours.
(2) Remove the end of the oil lamp tube that is clamped between the fingers of both hands and rotate it 90 degrees.

■ Cleaning work
(1) Please soak alcohol in gauze to wipe off any dirt on the surface of the reflector, acrylic board, and glass.
(2) Cleaning is required every 6 months to 1 year to maintain normal color temperature and brightness. We kindly ask for your assistance.

【5】 Before use

The viewer should pay attention to the following things because they are using glass products.
(1) Please do not give significant impact to the viewer entity.
(2) Please do not put aside anything that is heavy on the surface of the viewer.

DNP Standard color Viewer
The DNP Standard color Viewer is a light source which enables you to evaluateadjust videostill cameras. With its high-frequency Fluorescent lighting method, it handles images without flicker.

Specification

Light source: DNP Standard color Viewer lamp
(Four 10W dedicated fluorescent tubes are used)
Power supply: AC100V 50, 60Hz
Lighting method: High Frequency lighting method 20KHz
Color rendering: Over 90% rendering evaluation-point for each color
Color temperature: (Measured by Minolta CL-200)
Operating temperature: 10~40℃
Operating humidity: Below 80%(avoid dew)
Major diameter dimension: 375W×365H×165D m/m
Luminance plane dimension: 250W×190H m/m
Color chart dimension: 320W×290H m/m
Power consumption: 80W
Weight: 6.5kg/7.5kg