Zhengzhou Qutong Electrical Equipment Co., Ltd
Home>Products>10th edition pharmacopoeia drug heavy metal content - capsule chromium content analyzer
10th edition pharmacopoeia drug heavy metal content - capsule chromium content analyzer
10th edition pharmacopoeia drug heavy metal content detector - detecting chromium content in hollow capsules (graphite furnace method). It is recommen
Product details
The 10th edition pharmacopoeia drug heavy metal content detector - for detecting the chromium content in hollow capsules (graphite furnace method), it is recommended to use a microwave digestion instrument; And other elements such as copper, lead, arsenic, etc. in the raw materials and finished products of drugs (flame method or graphite furnace method can be used)
Fully automatic graphite flame integrated atomic absorption spectrophotometerIntroduction:A precision instrument mainly used to detect the content of trace/trace metal elements in various substances. It can detect more than 70 types of elements, including lithium, sodium, magnesium, aluminum, silicon, potassium, calcium, chromium, manganese, iron, cobalt, nickel, copper, zinc, arsenic, selenium, silver, cadmium, indium, tin, antimony, platinum, gold, lead, etc. The integrated flame atomizer and graphite furnace atomizer are designed with a detection limit of PPB level (parts per billion)

1Flame emission, deuterium lamp background correction, automatic zeroing, automatic ignition, automatic wavelength scanning, automatic display of measurement parameters, establishment of working curves, and measurement of sample concentration; The host is equipped with a control panel, which can achieve dual control of automatic and manual operation of the instrument (which can be operated by the control panel when the computer is not working);

2Wavelength testing range:190-900nm

3Accuracy:±0.2nm

resolving power:be better than0.3nm

Flame analysis characteristic concentration and detection limitCu< 0.03mg/l、< 0.005mg/l;

Baseline stability: 0.003A/30 minutes;

Background correction: Deuterium lamp method, 1A/hour30 times;

Element lamp: 6 lamps can be preheated and rotated simultaneously, with pulse power supply of 0-20mA;

3Burner: Pre mixed type100mmSingle seam burner,

Atomizer: Metal sleeve high-efficiency glass atomizer,

Position adjustment: height, horizontal, and rotational angle position adjustment;

Optical system: single beam dual lens optical path, grating5050mm、 1800 pieces/mm;

Spectral bandwidth: 0.2nm, 0.4nm, 2.0nm;

4Air path protection: automatic protection against power outages and air undervoltage; Ignition method: automatic ignition;

Measurement methods: energy, absorbance, concentration, background correction, flame emission;

5 Introduction to Graphite Furnace SystemThe graphite furnace atomization device is an electric heating atomization device, which is divided into two parts: a temperature control power supply and a graphite electric heating atomization device. After the atomization device is powered on, its temperature can reach up to nearly3000Degree can rapidly atomize the tested sample and retain it in the atomizer, resulting in significant spectral absorption and greatly improving the sensitivity of atomic absorption instruments. Widely used inpetrochemical industry Environmental monitoring, drinking water, food, hygiene, drug testing, non-ferrous metals, rock and mineral analysis and other fields.

characteristicLow sampling volume: Only sample solution is needed for a single sample measurement10-20μLEasy to operate: The intelligent design adopts computer full process control, and the heating program at each stage can achieve step heating or slope heating. The on/off of the internal and external protective gases can be freely set. When the cooling water pressure is too low or the water temperature is too hot, it can automatically alarm and stop heating up.

High measurement accuracy: The device is designed with an internationally advanced light controlled heating system, which achieves automatic full power heating during the sample atomization stage, improves the sensitivity and precision of the sample, and can effectively eliminate interference from various residual elements.

Graphite furnace systemMain technical indicators:

Scope of application: Analysis of trace amounts of metallic and semi metallic elements (such as lead, iron, and manganese)

Heating condition setting: with drying, ashing, atomization, and air burning steps

Heating methods: step heating, ramp heating, full power heating heating

Heating temperature range: room temperature -3000linear measure

Heating and temperature control method: The drying and ashing stage is controlled by voltage feedback, while the atomization stage is controlled by voltage or light feedback

Graphite tube fixing method: manual locking

Heating method: Vertical heating

Safety method: Water temperature exceeding limit alarm

Control mode: fully automatic program control by microcontroller

External dimensions:300*420*360MM Weight:20kg

6Data processing: automatic zero adjustment, instantaneous value, peak height value, integral value, range extension, curve straightening, response time selection;

Microcomputer workstation: Lenovo commercial computer, usingWindowsThe software, instrument working program, and working conditions are completely controlled by computers, and the analysis results can be edited, plotted, and tabular according to user needs for data processing functions;

7The electronic components in the instrument are all imported large-scale integrated circuits, and are all integrated on one circuit board, with low failure rate and easy maintenanceThis circuit board comes with a lifetime free warranty.

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!