Technical parameter table
What are the basic operation buttons and alarm functions of the IC board control panel of the screw air compressor? Each air compressor has a control panel, commonly used are IC board control panel and microcontroller control panel. So, I'm not quite sure about some of the buttons and alarm functions on the empty control panel of the IC board. Now, Euler's technicians will explain the operation buttons and alarm functions of the IC board control panel.
1、 Basic operation buttons:
1) Start up. Start the air compressor under normal working conditions.
2) Stop. Stop the air compressor under normal working conditions.
3) Emergency stop/reset. This button is pressed in emergency situations or when power on is not allowed
In the situation, take a picture and cut off the AC power. At this time, pressing the "start button" will not activate the air compressor controller
Oral response. Emergency stop and fault reset.
4) Remote, on-site switching. Switching between standalone control and integrated control.
2、 Alarm function:
1) Air filter blockage alarm;
2) Oil filter blockage alarm;
3) Oil fine separator blockage alarm;
4) Electrical light and heavy fault alarm, including phase sequence error (prohibited from starting), host over
Or (emergency stop), overload of the cooling fan (emergency stop);
5) High host temperature (emergency stop), high exhaust temperature (emergency stop);
6) High temperature alarm and water loss alarm for the cooler.
Product Comparison
Product principle and characteristics