One Product Introduction
ZT560intelligenceDigital pressure calibratorIt is our company's latest low-power, portable professional pressure calibrator, which features comprehensive functions, easy operation, and low standby power consumption. This product has functions such as pressure measurement, voltage measurement, current measurement, switch measurement, data recording and storage, and is the preferred choice for portable on-site verification. itapproveUsed for verifying pressure instruments such as general pressure gauges, precision pressure gauges, pressure (differential pressure) transmitters, pressure sensors, blood pressure monitors, etc. It can also be used in situations where precision pressure measurement is required. It is an updated product of pointer type precision pressure gauge.
ZT560Intelligent digital pressure calibratorAdopting imported pressure sensors andADThe highest level of precision in the companyADThe chip undergoes a series of aging procedures before leaving the factory to fully ensure the accuracy of its pressure measurement. This product adopts a large segmented LCD screen with backlight, which displays clear content and a large amount of information. Built in large capacity rechargeable lithium battery eliminates the hassle of frequent battery replacement, allowing for continuous use on a single full charge600Hours (turn off electrical testing), turn on electrical testing (output no-load) can work continuously45Hour. In addition, computer software can be optionally selected to facilitate data storage, calculation of indication errors, automatic generation of reports, report printing, and other tasks.
II PRODUCT FUNCTION
1.Can be used as a pressure standard to calibrate general pressure gauges, precision pressure gauges, pressure (differential pressure) transmitters, blood pressure monitors, pressure switches, and other pressure instruments and meters
2.Measurable-30V~30VDC voltage-30mA~30mAdc current
3.Can record pressure and electrical measurement data
4.OutputDC24V、1.5mA
5.Display auxiliary functions such as pressure percentage, real-time clock, ambient temperature, and adjustable sampling rate
III Model Selection Table
Model number |
Range |
accuracy class |
ZT560B-N100K ZT560C-N100K |
(-100~0)kPa |
0.02,0.05,0.1 |
ZT560C-5K |
(0~5)kPa |
0.1 |
ZT560B-10K ZT560C-10K |
( 0~10)kPa |
0.05,0.1 |
ZT560B-20K ZT560C-20K |
(0~20)kPa |
0.05,0.1 |
ZT560B-25K ZT560C-25K |
(0~25)kPa |
0.05,0.1 |
ZT560B-40K ZT560C-40K |
(0~40)kPa |
0.05,0.1 |
ZT560B-60K ZT560C-60K |
(0~60)kPa |
0.05,0.1 |
ZT560A-100K ZT560B-100K |
(0~100)kPa |
0.02,0.05 |
ZT560A-160K ZT560B-160K |
(0~160)kPa |
0.02,0.05 |
ZT560A-250K ZT560B-250K |
(0~250)kPa |
0.02,0.05 |
ZT560A-600K ZT560B-600K |
(0~600)kPa |
0.02,0.05 |
ZT560A-1M ZT560B-1M |
(0~1)MPa |
0.02,0.05 |
ZT560A-2M ZT560B-2M |
(0~2)MPa |
0.02,0.05 |
ZT560A-2M5 ZT560B-2M5 |
(0~2.5)MPa |
0.02,0.05 |
ZT560A-4M ZT560B-4M |
(0~4)MPa |
0.02,0.05 |
ZT560A-6M ZT560B-6M |
(0~6)MPa |
0.02,0.05 |
ZT560A-10M ZT560B-10M |
(0~10)MPa |
0.02,0.05 |
ZT560A-16M ZT560B-16M |
(0~16)MPa |
0.02,0.05 |
ZT560A-20M ZT560B-20M |
(0~20)MPa |
0.02,0.05 |
ZT560A-25M ZT560B-25M |
(0~25)MPa |
0.02,0.05 |
ZT560A-30M ZT560B-30M |
(0~30)MPa |
0.02,0.05 |
ZT560A-40M ZT560B-40M |
(0~40)MPa |
0.02,0.05 |
ZT560A-60M ZT560B-60M |
(0~60)MPa |
0.02,0.05 |
ZT560B-100M ZT560C-100M |
(0~100)MPa |
0.05,0.1 |
ZT560B-160M ZT560C-160M |
(0~160)MPa |
0.05,0.1 |
ZT560B-250M ZT560C-250M |
(0~250)MPa |
0.05,0.1 |
Explanation: 1 The letters "A, B, C" in the model indicate the accuracy level, A: 0.02 level B: 0.05 level C: 0.10 level.
2. "-" is followed by the range: N represents negative, K and M represent units of kPa and MPa, respectively. The value before the unit represents an integer value, and the value after it represents a decimal value; For example, N100K represents -100kPa, and 2M5 represents 2.5MPa.
3.0.02 ensures accuracy within a temperature range of (20 ± 5) ℃; 0.05 level and 0.1 level ensure accuracy within a temperature range of (-10~50) ℃ The time for ensuring accuracy is one year.
Please be advised that due to market development and product development needs, the relevant content in this product information may be updated or modified at any time based on actual circumstances without prior notice. We apologize for any inconvenience caused.