The ZGF series DC high voltage generator adopts a high-frequency voltage doubling circuit, applies advanced PWM high-frequency pulse width modulation technology, closed-loop adjustment, and adopts voltage feedback to greatly improve voltage stability. Utilize high-performance high-power IGBT devices and driving technology, and adopt special shielding, isolation, and grounding measures based on electromagnetic compatibility theory. The DC high-voltage generator achieves high quality, portability, and can withstand rated voltage discharge without damage. It has the characteristics of high output power and small size, reliable overvoltage, overcurrent, and zero position closing protection functions, and has a 0.75 times voltage switching function. Using new technologies, materials, and devices, it has the characteristics of high output power, small size, and light weight. It has reliable overvoltage, overcurrent, and zero position closing protection functions, with a 0.75 times voltage latch function, and is equipped with a time relay that can set timed voice alarms during testing. The entire instrument is easy to carry, easy to operate, and safe and reliable.
It is mainly suitable for power departments, industrial and mining, metallurgy, steel and other enterprises to conduct DC withstand voltage tests or DC leakage current tests on high-voltage electrical equipment such as zinc oxide lightning arresters, power cables, transformers, circuit breakers, generators, etc.
Scope of application:
1. Conductivity current test of valve type lightning arrester.
2. DC withstand voltage test and leakage current measurement of power transformers.
3. DC withstand voltage test and leakage current measurement of high-voltage cables (35-500kV and below).
4. U1mA DC reference voltage test and 0.75U1mA leakage current test for zinc oxide lightning arrester.
Product nickname: DC High Voltage Generator, DC High Voltage Generator, High Voltage Generator, Medium Frequency DC High Voltage Generator, Portable DC High Voltage Generator, ZGF DC High Voltage Generator, Power Frequency High Voltage Generator, High Voltage Generator DC High Voltage Generator.
Specification parameters | 200/2 | 200/3 | 200/5 | 300/2 | 300/3 | 300/5 |
Rated voltage (kV) | 200 |
200 | 200 | 300 | 300 | 300 |
Rated current (mA) | 2 |
3 | 5 | 2 | 3 | 5 |
Rated power (W) | 400 |
600 | 1000 | 600 |
900 | 1500 |
Control box mass (kg) | 5.5 |
6 | 6.5 | 6.5 | 6.5 | 7.5 |
Mass of pressure doubling cylinder (kg) | 8.7 |
9 | 9 | 11 | 11 | 11.5 |
Height of pressure doubling cylinder (mm) | 970 |
970 | 970 | 1250 | 1250 | 1250 |
Voltage accuracy | ± (1.0% reading+2 words) | |||||
current accuracy | ± (1.0% reading+2 words) | |||||
ripple factor | ≤0.5% | |||||
voltage stability | ≤ 1% when the power supply voltage changes by ± 10% | |||||
Overload capacity |
The no-load voltage can exceed the rated voltage by 10% and be used for 10 minutes | |||||
The maximum charging current is 1.25 times the rated current | ||||||
power supply | Single phase AC 50Hz 220V ± 10% | |||||
way of working |
Intermittent use: rated load for 30 minutes | |||||
1.1 times rated voltage usage: 10 minutes | ||||||
work environment |
Temperature:- 10℃~+40℃ | |||||
Relative humidity: not exceeding 85% at room temperature of 25 ℃ (no condensation) | ||||||
Altitude: below 1500 meters | ||||||
Capacity with capacitive load |
The capacitance of the test sample is unlimited | |||||
Can be charged with 1.5 times the rated current | ||||||
Structural characteristics |
Electrical insulation voltage doubling cylinder | |||||
Air insulation, no leakage concerns | ||||||
Characteristics of the operation box |
High precision 0.75UDC1mA single touch button (accuracy ≤ 1.0%), suitable for testing zinc oxide lightning arresters | |||||
Overvoltage protection adopts digital dip switch, which is clear at a glance | ||||||
Portable chassis, more convenient on-site | ||||||
Protection function |
Internal overvoltage protection, internal overcurrent protection | |||||
External overvoltage protection (adjustable protection voltage), external overcurrent protection or breakdown protection | ||||||
Internal power protection | ||||||
Non zero start protection | ||||||
Timed voice alarm |
Attachment List:
Serial Number |
name | quantity |
1 | control box | 1 unit |
2 | High pressure multiplier cylinder | 1 unit |
3 | High voltage cable |
2 pieces |
4 | discharging rod | 1 piece |
5 | water resistance | 1 piece |
6 | power line | 1 piece |
7 | fuse | 2 of them |
8 | Special grounding wire | 1 piece |
9 | Microampere meter | 1 piece |
10 | instructions | 1 book |
11 | inspection report | 1 copy |
12 | certificate of conformity | 1 sheet |
Note:1. The appearance of the product is subject to the actual product. Technical parameters and models are subject to change without prior notice. If there is any act of theft or copying, legal responsibility will be pursued
2. To learn more about Huayi products, please enter the product center. Service Hotline:
Selection Reference - Zinc Oxide Surge Arrester DC Reference Voltage and Leakage Current Test
Rated voltage of lightning arrester (kV) | 10 | 35 |
66 | 110 | 220 |
DC reference voltage kV | 28 | 90 | 135 | 168 | 314 |
Equipment selection kV/mA | ZGS - 60 / 2 | ZGS - 120 / 2 | ZGS - 200 / 2 | ZGS - 200 / 2 | ZGS - 400 / 3 |
Selection reference - choose according to the voltage level of the substation
Substation voltage level kV | 10 | 35 | 66 | 110 | 220 | 330 |
Maximum test voltage kV | 47 | 105 | 135 | 192 | 305 | Greater than 400 |
Equipment selection kV/mA | ZGS- 60 / 2 | ZGS - 120 / 2 | ZGS - 200 / 2 | ZGS - 200 / 2 | ZGS - 400 / 3 | ZGS- 800 / 10 |
Selection reference - choose based on the qualification level of repair and testing
Maintenance and testing level | Level 5 | Level 4 | Level 3 | Level 2 | Level 1 |
Maximum test voltage kV | 28 | 90 | 168 | 305 | Greater than 400 |
Equipment selection kV/mA | ZGS- 60 / 2 | ZGS- 120 / 2 | ZGS- 200 / 2 | ZGS- 400 / 3 | ZGS- 800 / 10 |
Selection reference - DC withstand voltage and leakage current test of paper insulated cable
Rated voltage of cable Uo/U kV | 3.6 / 6 | 6 / 6 | 6 / 10 | 8.7 / 10 | 21 / 35 | 26 / 35 |
DC test voltage kV | 17 | 30 | 40 | 47 | 105 | 130 |
Equipment selection kV/mA | ZGS- 60 / 2 | ZGS- 60 / 2 | ZGS- 60 / 2 | ZGS- 60 / 2 | ZGS- 120 / 3 | ZGS- 200 / 5 |
Selection reference - Rubber insulated cable DC withstand voltage and leakage current test
Rated voltage of cable Uo/U kV | 6 / 10 | 8.7 / 10 | 21 / 35 | 26 / 35 | 48 / 66 | 64 / 110 | 127 / 220 |
DC test voltage kV | 26 | 37 | 63 | 78 | 144 | 192 | 305 |
Equipment selection kV/mA | ZGS- 60 / 2 | ZGS- 60 / 2 | ZGS- 120 / 5 | ZGS- 120 / 5 | ZGS- 200 / 5 | ZGS- 200 / 10 | ZGS- 400 / 5 |
Selection reference - DC withstand voltage and leakage current test for main insulation of self accommodating oil filled cable
Rated voltage of cable Uo/U kV | 48 / 66 | 64 / 110 | 127 / 220 | 190 / 330 | 290 / 500 |
DC test voltage kV | 175 | 275 | 475 | 585 | 775 |
Equipment selection kV/mA | ZGS- 200 / 3 | ZGS- 300 / 3 | ZGS- 500 / 5 | ZGS- 600 / 5 | ZGS- 800 / 10 |
1. High precision and accurate measurement. The voltmeter on the control box directly displays the voltage value applied to the load test sample, without the need for an external voltage divider during use, and the wiring is simple. The instrument has high and low voltage ends for measuring leakage current, and the high voltage end is displayed with a circular shielded digital meter, which is not afraid of discharge shock and has good anti-interference performance, suitable for on-site use;
2. High voltage regulation stability, smooth voltage regulation across the entire range, output voltage regulation using imported single multi turn potentiometers, smooth boosting process, and high regulation accuracy;
3. Negative polarity output, zero start, continuously adjustable, with various protection functions such as overvoltage, overcurrent, return to zero, grounding protection, and unique disconnection protection. The automatic protection circuit has strong functions, complete and reliable protection, and ensures safe operation;
4. Adopting the most advanced technology and process manufacturing, taking the lead in applying intermediate frequency voltage doubling circuit, adopting the latest PWM high-frequency pulse width modulation technology and high-power IGBT devices, thus achieving higher output high voltage stability and smaller ripple coefficient;
5. Adding high-precision 0.75UDC1mA function brings great convenience to making DC high-voltage generators;
6. The overvoltage setting adopts a digital dip switch, which can intuitively display the set voltage value, with the displayed value unit in kV, making it clear at a glance;
7. The fault sampling adopts a dedicated sensor with an action time of nanoseconds, and the optical isolation element is also nanosecond level, which can quickly and completely turn off the DC main circuit, thus maximizing the protection of the instrument from damage;
8. The double pressure cylinder adopts new materials, which are lightweight and sturdy. There are three concealed support feet at the bottom, which increase the stability of the pressure doubling cylinder. The exterior is coated with special insulation material, which has good electrical performance and strong moisture resistance;
9. The chassis adopts aluminum alloy chassis, which is small in size, lighter in weight, more beautiful, more reliable, easy to operate, fully functional, and convenient for outdoor use;
Product Attachment Diagram
-
ZGS series DC high voltage generator
-
ZGS series DC high voltage generator
-
ZGS series DC high voltage generator multiplier cylinder
-
ZGS series DC high-voltage generator chassis
-
ZGS series DC high voltage generator multiplier cylinder
-
ZGS series DC high-voltage generator connection wire
-
ZGS series DC high voltage generator high voltage line
-
ZGS series DC high-voltage generator discharge rod
-
ZGS series DC high voltage generator microampere meter
-
ZGS series DC high-voltage generator dedicated grounding wire
-
ZGS series DC high-voltage generator mainframe box
-
ZGS series DC high voltage generator double pressure cylinder base
Product detail diagram
-
ZGS series DC high voltage generator multiplier cylinder
-
ZGS series DC high voltage generator multiplier cylinder
-
ZGS series DC high voltage generator multiplier cylinder
-
ZGS series DC high voltage generator multiplier cylinder