English

Wuxi Hongtai Electric Motor Co., Ltd
Home>Products>YZB (F) variable frequency lifting metallurgical motor
Product Groups
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
  • Address
    No. 17 Wanshou Road, Qianzhou Town Industrial Park, Huishan District, Wuxi City, Jiangsu Province
Contact Now
YZB (F) variable frequency lifting metallurgical motor
Product Overview: The YZB (F) series of variable frequency three-phase asynchronous motors for lifting and metallurgy are a combination of the charact
Product details

Product Overview:
Variable frequency series three-phase asynchronous motor for lifting and metallurgy
The YZB (F) series variable frequency speed regulation three-phase asynchronous motor (hereinafter referred to as the motor) for lifting and metallurgy is a combination of the characteristics of three-phase asynchronous motors for crane metallurgy and the advantages of variable frequency speed regulation. It has the characteristics of high overload capacity, high mechanical strength, wide speed regulation range, and stable operation. It can be applied to various types of cranes, metallurgical machinery, or other similar equipment, as well as situations where lifting, braking, and reversing are frequent.
The electric motor can operate normally under the following conditions.
(1) The ambient temperature shall not exceed 40 ℃ for F-class insulated motors and 60 ℃ for H-class insulated motors.
(2) Relative temperature ≤ 90%.
(3) The altitude shall not exceed 1000m.
(4) Frequent starting, braking (electrical or mechanical), and reversing.
The rated voltage of the motor is 380V, the rated frequency is 50Hz, and it can be continuously adjusted within the range of 5-100Hz.
The benchmark working system for electric motors is S3-40%.
4 Model Description

Technical data: 



Note: 1. Locked rotor torque/rated torque at 5Hz value
2. Maximum torque/rated torque at 50Hz

Structure of electric motor:
Protection level: The motor protection level is IP44, which can also be made into IP54 according to user requirements, and the cooling fan protection level is IP23. Cooling method: The motor cooling method is fully enclosed axial fan cooling (IP416), or other cooling methods can be made according to user requirements. The installation type of the motor structure is shown in the table below:

Installation and installation form code name Manufacturing scope (machine base number)
1M1001 100~160
1M1003 180~355
1M1002 100~160
1M1004 180~355
1M3001 100~160
1M3003 180~225
1M3011 100~160
1M3013 180~315

Insulation level: The insulation level of the motor is F (for general environmental use) and H (for metallurgical environments). Junction box: The motor stator junction box can be located at the top of the machine base, or on the right or left side of the machine base according to user requirements.

Installation and external dimensions:
1 YZB (F) series IM1001, IM1003, IM1002, IM1004 horizontally installed motors with base feet and end caps without flanges


machine
seat
number
Installation dimensions and tolerances Overall dimensions
A A/2 B C D D1 E E1 F G H K bolt diameter AB AC BB HA HD L CL
basic size limit
bias
basic size limit deviation basic size limit
bias
basic size basic size limit
bias
basic size limit deviation basic size limit deviation basic size limit deviation
100L 160 80 140 63 ±2 28 +0.008
-0.004
60 ±0.37 8 0
-0.036
24 0
-0.2
100 0
-0.5
12 +0.043
0
M10 205 215 200 12 250 500 395
112M 190 95 140 70 32 80 10 27 112 250 245 235 15 330 590 505
132M 216 108 178 89 38 33 132 275 285 260 17 360 645 577
160M 254 127 210 108 ±3 48 +0.018
+0.002
110 ±0.43 14 0
-0.043
42.5 160 15 M12 320 325 290 20 420 758 718
160L 254 335 800 762
180L 279 139.5 279 121 55 M36×3 82 19.9 180 360 360 380 22 460 870 800
200L 318 159 305 133 60 M42×3 140 ±0.50 105 16 21.4 200 19 +0.052
0
M16 405 405 400 25 510 975 928
225M 356 178 311 149 ±4 65 23.9 225 455 430 410 28 545 1050 998
250M 406 203 349 168 70 M48×3 18 25.4 250 24 M20 515 480 510 30 605 1195 1092
280S 457 228.5 368 190 85 M56×4 170 130 20 0
-0.052
31.7 280 0
-1.0
575 535 530 32 665 1265 1180
280M 419 580 1315 1240
315S 508 254 406 216 95 M64×4 22 35.2 315 28 M24 640 620 35 750 1390 1310
315M 457 630 1440 1360
355M 610 305 560 254 110 M80×4 210 ±0.58 165 25 41.9 355 740 710 730 38 840 1650 1610
355L 630 800 1720 1680

YZB (F) series IM3001, IM3003, IM3011, IM3013 vertical installation, motor base without feet, end cover with flange


machine
seat
number
Installation dimensions and tolerances Overall dimensions
Concave edge code D D1 E E1 F G M N P S bolt diameter T
maximum
Number of holes (pieces) AD L LA LB
basic size limit deviation basic size limit
bias
basic size basic size limit
bias
basic size limit deviation basic size limit
bias
basic size limit
bias
100L FF215 28 +0.008
-0.004
60 ±0.37 8 0
-0.036
24 0
-0.2
215 180 +0.014
-0.011
250 15 +0.043
0
M12 4 4 180 500 14 440
112M 32 +0.018
+0.002
80 10 27 265 230 +0.016
-0.013
300 220 590 510
132M FF265 38 33 300 250 350 19 +0.052
0
M16 5 230 640 560
160M FF300 48 110 ±0.43 14 0
-0.043
42.5 250 820 18 710
160L 870 760
180L 55 M36×3 82 19.9 280 910 800
200L FF400 60 M42×3 140 ±0.50 105 16 21.4 400 350 ±0.018 450 8 320 1050 20 910
225M 65 23.9 1110 970
250M FF500 70 M48×3 18 25.4 500 450 ±0.020 550 385 1280 22 1140
280S 85 M56×4 170 130 20 0
-0.052
31.7 435 1380 1210
280M 1430 1260
315S FF600 95 M64×4 22 35.2 600 660 ±0.022 660 M20 6 520 1490 25 1320
315M 1540 1370
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!