VIP member
YN194PF-1X1 single-phase digital power factor meter
● Measurement: Single phase power factor ● Display: A row of digital tubes (LEDs) display STN blue screen, wide viewing angle, high-quality, high-defi
Product details

PRODUCT MODEL | measure | display | Peripheral functions | |||
rs485 communication | analog output | Switching input | ALARM IN | |||
YN194PF-1X1 | Measurement: PF | Single row: LED | not have | not have | not have | not have |
YN194PF-1K1 | Optional | Optional Route 1 AO |
Optional 1-2 DI channels |
Optional 1-2 DO routes |
||
YN194PF-1KY | Single row: LCD |
characteristic:
Measurement: Single phase power factor● Display: A row of digital tubes (LEDs) display STN blue screen, wide viewing angle, high-quality, high-definition LCD screen display.
Communication: RS485 communication, MODBUS-RTU protocol. It has networking communication function.
● Input: 2-channel switch input (2DI).
Output: 2-channel switch output (2DO), 1-channel analog output (1AO).
Voltage transformers are required for AC500V and above
summary:
The digital intelligent single-phase power factor meter is suitable for measuring and displaying electrical parameters such as current, voltage, frequency, active power, reactive power, and power factor in power grids and automation systems. By setting the magnification on the panel, it intuitively displays the operating point parameters of the system's primary side. It has the advantages of high accuracy, good stability, and anti vibration, and can directly replace the original pointer type instrument.Technical indicators:
performance | parameter | ||
transport enter measure measure apparent show |
voltage | RATING | AC500V (other specifications, please specify when ordering) |
overload | Overload: 1.2 times instantaneous: 10 times/10 seconds | ||
power consumption | < 1VA (per phase) | ||
impedance | >500KΩ | ||
accuracy | RMS measurement, accuracy level 0.5 | ||
electric current | RATING | AC5A (other specifications, please specify when ordering) | |
overload | Overload: 1.2 times instantaneous: 10 times/10 seconds | ||
power consumption | < 0.4VA (per phase) | ||
impedance | >2MΩ | ||
accuracy | RMS measurement, accuracy level 0.5 | ||
frequency | resolution | 0.01HZ | |
frequency | 45~65HZ | ||
power | accuracy | Active power accuracy level 1.0, reactive power accuracy level 1.5 | |
power supply | scope of work | AC/DC85~270V | |
power consumption | ≤5VA | ||
output | Digital Interface | RS485, MODBUS-RTU protocol | |
environment | work environment | -10~55℃ | |
Environment | -20~75℃ | ||
secure | pressure resistance | Input/power>2kV, input/output>2kV, power/output>1kV | |
isolation | Input, output, and power supply to the chassis>50M Ω |
Wiring method:
Additional features:

Example of ordering:
When signing the contract, please provide detailed information such as product model, input signal, wiring method, etc. This series of products comes with a default appearance setting as standard. If customers have special requirements, please specify them in detail in other projects.Model: YN194PF-1X1 (single-phase power factor meter)
Input: AC220V,/5A
Communication interface: RS485/MODBUS-RTU