The xenon lamp weather resistance test chamber complies with the GB/T16422.2-99 standard and is mainly used for simulating environmental climate aging
Product details

1、 Explanation

The climate environment has a significant impact on the aging of organic matter, fading of pigments, and corrosion of metals. Therefore, aging tests are increasingly receiving attention from industries such as rubber, plastics, paints, petrochemicals, automobiles, and textiles. There are many climatic and environmental factors, such as sunlight, temperature, humidity, rain, and condensation; It is not comprehensive enough to evaluate the performance of materials based solely on a single environmental factor test, such as harmful gases and dust. Often, a combination of multiple factors must be tested to simulate natural conditions as much as possible in order to make a more accurate evaluation. Although outdoor exposure tests have good authenticity, the climate conditions vary in different regions and seasons. Therefore, the importance of experimentation is relatively low, and with the continuous improvement of sample material quality, the exposure testing cycle is becoming longer and longer, which cannot meet the needs of the continuous development of scientific research and production. The xenon lamp gas resistance test chamber has six environmental factors including lighting, rain, humidity, and condensation, and can be independently adjusted. It uses a xenon lamp as the light source and has a spectral distribution similar to that of sunlight. Therefore, xenon light is used to simulate sunlight. At the same time, a wide range of temperature and humidity regulation is available for adjustment, and an independent circulation system is adopted for rain. Therefore, when necessary, harmful gas substances can be added to the water supply source for rain. By changing the cooling water temperature of the sample rack, the condensation amount on the surface of the sample and the surface temperature of the specimen can be adjusted. Therefore, this test chamber can be used for a combination of multi factor weather resistance tests.

2、 Meet the standards

The GB/T16422.2-99 standard is mainly used for simulating environmental climate aging (acceleration) tests on non-metallic materials, especially organic materials (such as paints, coatings, rubber, plastics, building materials, textiles and fabrics) and other chemical materials.

3、 Technical indicators

1Temperature range: RT+10 ℃~70 ℃

2Temperature uniformity: ± 2 ℃

Temperature fluctuation: ± 1 ℃

3Humidity range: 50-95% R · H adjustable

4Humidity fluctuation: ± 3% R · H

Humidity uniformity: ± 2.5% R · H

5Rainfall duration: continuously adjustable from 0 to 99 hours

The spray water is distilled water and filtered through a filter;

6Light cycle: continuously adjustable from 0 to 99 hours

7Light source:

Cooling method: water-cooled xenon arc lamp

Xenon lamp power: 6KW ± 10%;

Wavelength 290-800 nanometers

Amplitude illumination: 450-780W/Usually choose 550 W/

8Distance between sample holder and lamp: 300-375mm (adjustable)

9Heating power: 2KW

10Humidification power: 2KW

11Sample rack: 1-5 revolutions per minute, 360 ° rotation

12Sample: 70 * 150 * 1mm standard sample

13Studio size: 950 * 950 * 850 (D × W × H) (mm)

14. Outer box size: 1250 × 1850 × 1350 (D × W × H) (mm)

15Blackboard temperature: 55-85 ℃, reference value for exposure experiment is 65 ℃± 3 ℃

4、 Structure and Configuration

AStructure:

Inner box material: Smooth 304 # stainless steel plate, beautiful and easy to clean

Outer box material: A3 steel plate electrostatic spraying

Heater: Nickel chromium wire heating, heating power 2KW

Humidifier: UL type electric heater that generates vapor humidification through surface evaporation

Insulation material: hard PU foam+ultra-fine glass fiber cotton

Box door: Single panel door, single window, left opening, handle on the right-hand side

aGlass window

b.Flat embedded handle

c.Rear button: SUS # 304

BSupply air circulation system: positive forced supply air circulation method, single circulation centrifugal fan, and split flow air duct structure.

  1. Air conditioning sealed motor, not prone to oil loss and choke
  2. Stainless steel axis, rusted
  3. Multi blade fan stirs and circulates air to make the temperature more uniform

CControl system:

1Imported Fuji digital controller from Japan

2. Key setting input

3Resolution: 0.1 ℃

4Temperature range: 0 ℃~120 ℃

5Sensor: PT100 test sensor (2 pieces, platinum sensing)

D. Heater

  1. Heater: Nickel chromium wire electric heating
  2. Humidifier: Stainless steel tube sheathed humidifier
  3. Heater control method: contactless equal period pulse width modulation, SSR (solid-state relay)

EFreezing system:

  1. Working mode: single-stage refrigeration mode of air-cooled mechanical compressor
  2. Refrigeration compressor: Original French "Taikang" fully enclosed compressor unit
  3. Cooling method: air cooling
  4. Evaporator: finned multi-stage type
  5. Refrigerant: Environmentally friendly refrigerant
  6. Condenser: air-cooled coil condenser
  7. Control mode of refrigeration compressor:

aThe control system automatically adjusts the operating conditions of the refrigeration compressor according to the test conditions

bEvaporator Pressure Regulator

cCompressor return air cooling circuit

dEnergy regulation circuit

FSchneider from France executes electronic components

GBlackboard thermometer: bimetallic blackboard thermometer, 55-85 ℃

Japanese "Fuji" digital controller with LED display

Sensor: PT100 Test Sensor (1, Platinum Sensing)

HXenon lamp tube: Shanghai Shuguang Lighting Factory

Xenon lamp trigger: Shanghai Shuguang Lighting Factory

IRecord: Cumulative Time Recorder

Total test time: 0~9999H

JLighting time controller: Taiwan Taian programmable controller with Chinese and English screen display

KProtection device:

K.1refrigeration system

Compressor overpressure; Compressor motor overheating; Compressor motor overload

K.2laboratory

Overtemperature protection; Humidifier air burning protection; Water tank water shortage protection

K.3other

Main power phase sequence and phase loss protection; Leakage protection

Five Standard configuration

1 roll of dry wet ball gauze

1 xenon lamp tube

1 copy each of the equipment user manual, warranty card, and certificate of conformity

Radiometer is an optional component