VIP member
XY series intelligent temperature and humidity field
XY series intelligent temperature and humidity field
Product details
XYSeries intelligent temperature and humidity field recorder

XYThe temperature and humidity field recorder consists of a true color TFT LCD screen, buttons, a motherboard with ARM microprocessor as the core, a main power supply, an external transmitter power supply, an intelligent channel board, and a large capacity FLASH.
Can be equipped with different types of intelligent channel boards, selected according to application requirements
Built in large capacity FLASH, which can quickly transfer data from FLASH to the computer through a USB flash drive. The built-in FLASH has a capacity of 64M and the recording interval can be freely set between 1-60 seconds. There are two recording methods: non cyclic and cyclic.
Digital display screen, bar chart display screen, real-time curve screen, recall curve screen
Recall curve reading cursor function
Measurement, display, and recording accuracy; 0.2% F· S
2Point alarm function
3. technical specifications
3.1 display
320× 234 resolution, field of view size 103× 79(mm)
There are four basic screens: digital display screen, bar chart display screen, real-time curve screen, and recall curve screen
The basic error is less than± 0.2%F· S, Digital display range -1999~9999
Measurement resolution: 1/60000, 16 bit AD converter
Real time curve recording interval of 0.1 seconds to 60 seconds and 8 levels, corresponding to a full screen curve time of 30 seconds to 300 minutes (0.1 seconds is only applicable for channels below 16)
The interval for recording the recall curve can be set continuously from 0.1 seconds to 60 seconds. You can choose between cyclic or non cyclic recording methods
3.2 Input signal
The input signals include five categories: DC current, DC voltage, thermistor, thermocouple, and remote pressure gauge, which can be selected through button input.
Direct current: (4~20)mA,(0~10)mA,(0~20)mA
DC voltage: (1~5)V ,(0~5)V
Thermal resistance: Pt100,Cu100,Cu50,BA1,BA2,G53
Thermocouple: K,S,R,B,N,E,J,T
DC voltage: (1~5)V ,(0~5)V
Thermal resistance: Pt100,Cu100,Cu50,BA1,BA2,G53
Thermocouple: K,S,R,B,N,E,J,T
Other input signals or division marks need to be specified when ordering.
3.3 ALARM IN
Relay output: Contact capacity 220V AC, 3A, resistive load
Shared 2 alarm points, can be set according to the values of each alarm point in the channel
3.4 External power supply
24V DCPower supply: used to power the transmitter, with a load capacity of ≥ 200mA
3.5 communication interface(Select Function)
Photoelectric isolation
RS232、 RS485 standard, please specify when ordering
Communication speed 96001920057600115200 selected through setting
Supporting testing software, providing technical support for configuration software and application software
Optional Modbus RTU communication protocol for communication with the upper computer
3.6 Power supply conditions
220V ACPower supply instrument: 220V± 10%, power consumption less than 15VA
24V DCPower supply instrument: 24V± 10%, power consumption less than 15VA
Note: The actual power consumption is related to the total number of channels in the instrument
3.7 environment
Working temperature range: 0 ℃~50 ℃
Storage temperature range:- 20℃~60℃
Working humidity range: below 85% R.H