Functional Features
※ Input signal0~10mA,4~20mA,1~5V,0~5VUniversal.
※ Intelligent design of microcontroller, long-term operation without drift.
※ maintain24The number, cumulative time, and maximum or minimum values of over limit alarms for each shift (three or four shifts can be set) within an hour.
※ With furnace negative pressure0~10mA、4~20mA、1~5V、0~5VIsolate the transmission output.
※ Can be carriedRS485/ RS232/ModemWait for isolated communication interface.
TECHNICAL INDEX
※ Usage conditions: |
ambient temperature: 0~50℃relative humidity:≤90% |
※ Power supply voltage: |
AC90V~265V (50~60HZ)perhapsDC24±10%V |
Basic error: |
0.5%F. Sscholar1character |
※ Display resolution: |
0.001, 0.01, 0.1, one |
※ Input characteristics: |
Electric couple type:Input impedance greater than10MΩ |
Also obstructive type:lead resistanceimportantask0~5Ω,Three lines are equal |
|
voltage source:Input impedance greater than300kΩ |
|
current mode:Input impedance less than or equal to250Ω |
|
※ Output characteristics: |
Relay capacity: 3A/220VACperhaps3A/24VDC,Resistive load |
48×96Small watch and96×96Fang Ai.0.5A/240VAC |
|
Output load impedance of current type transducer:less than600Ω |
|
Voltage type AC output load:greater than200KΩ |
|
※ Internal cold end Compensed Temperature Range: |
0~50℃ |
※ Transmitter power output: |
voltage24scholar10%VDC,Maximum current30mA,Can be directly connected to a two-wire passive transmitter |
※ Power consumption: |
<3W |
※ Weight: |
< 0.5kg |
Instrument appearance and dimensions
shape(mm): 160×80×80 80×160×80 96×96×110
hole(mm): 152+1.00×76+0.74 76+0.74×152+1.00 92+0.87×92+0.87
XMH5000Series furnace negative pressure digital recorder
type table |
speak bright |
||||||||
XMH |
Furnace negative pressure monitoring recorder |
||||||||
Design sequence |
5 |
switch power supply |
|||||||
control type |
3 |
Upper and lower limit records, upper and lower limit alarms |
|||||||
Input signal class type |
6 |
4~20mA/0~10mA/1~5V/0~5VEnter universal |
|||||||
Transmission output class type |
0 |
Without transmission output |
|||||||
6 |
furnace negative pressure4-20mA/0-10mA/1-5V/0-5VTransmission output |
||||||||
outline structure class type |
160×80×80mmhorizontal table |
||||||||
V |
80×160×80mmVertical Table |
||||||||
F |
96×96×110mmSquare Table |
||||||||
become different deliver implement power distribution |
Default is without DC power output |
||||||||
P |
belt24VDC(25mA)Power Output |
||||||||
power supply class type |
power supply220VAC |
||||||||
D |
power supply24VDC |
||||||||
communication interface class type |
Without communication interface |
||||||||
RS232 |
RS232Isolation communication interface |
||||||||
RS485 |
RS485Isolation communication interface |
||||||||
MODEM |
ModemIsolation interface |
||||||||
PRN |
Serial standard printing interface |
||||||||
Special function code |
□□□□ |
0000Indicates no special function code, |
Example explanation:
XMH5360PPRN0000
XMH5000Series furnace negative pressure digital recorder, upper and lower limit alarm for upper and lower limit recording, standard signal input,160×80mmhorizontal table,belt24VDCPower output, with serial standard printing interface, no special function code..
Instrument wiring diagram
XMH5000Series wiring diagram(I) |
XMH5000Series wiring diagram(II) |