Hebi Xinda Instrument Co., Ltd
Home>Products>X-ray fluorescence sulfur analyzer | Determination of sulfur content in ship fuel oil | X-ray sulfur content analyzer
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    18603925515
  • Address
    Middle section of Hongqi Street, Shancheng District, Hebi City
Contact Now
X-ray fluorescence sulfur analyzer | Determination of sulfur content in ship fuel oil | X-ray sulfur content analyzer
1. The ship fuel oil sulfur analyzer is designed with an integrated mechanical and electrical microcomputer, which is simple and beautiful; 2. Wide va
Product details

Environmental pollution has attracted close attention from governments and the public around the world, and the demand for protecting the ecological and atmospheric environment is increasing day by day. Humans cannot do without 5 minutes of air, 95% of which is distributed within a thickness of 12km on the Earth's surface. The main culprit causing atmospheric damage and pollution is CO2And SO2Emissions. CO2And SO2The lower the sulfur content of gasoline, diesel, heavy oil, and other fuels used in vehicles, ships, and aircraft, the greater the reduction in atmospheric pollution caused by the combustion of power fuels. Both Europe and China have established a series of sulfur-containing standards to restrict production and emissions. SO2It can also cause catalyst poisoning in the petrochemical industry and pose hazards such as acid rain in the atmosphere.
The X-ray fluorescence sulfur analyzer is a specialized X-ray fluorescence analyzer developed and manufactured to meet the needs of detecting sulfur content in oil products. It adopts the principle of energy dispersion and is designed with an integrated electromechanical microcomputer for fast and accurate analysis. Its repeatability and reproducibility meet the relevant requirements of national standard GB/T17040 and petrochemical industry standard SH/T0742, and also fully comply with the stricter requirements of American national standard ASTMD4294-03. It provides an important means for detecting sulfur content in crude oil or petrochemical production processes. The instrument itself is green and environmentally friendly, and its price is only a fraction of imported instruments
1.2 Main purpose
1. Measure the total sulfur mass percentage content of crude oil, petroleum, heavy oil, diesel, kerosene, gasoline, and naphtha;
2. Measure the total sulfur content in coal chemical products, such as primary benzene;
3. Measurement of total sulfur or sulfide content in other liquid samples;
4. In fine powder samples, such as petroleum coke modified asphalt, carbon, total sulfur, or SO3Determination of content.

1.3X fluorescence sulfur analyzerInstrument characteristics
1. Integrated microcomputer design of instrument electromechanical system, simple and beautiful;
2. Wide variety of detection, wide detection range, fast analysis speed, and low consumption of standard samples;
3. Adopting the relative comparison analysis method of fluorescence intensity ratio, temperature and atmospheric pressure are automatically corrected, and the carbon hydrogen ratio (C/H) can also be corrected;
4. IPS 8-inch capacitive touch screen, high brightness, clear visibility under sunlight, adjustable brightness; The software interface is clear and friendly, with simple operation;
5. Determine the working status and electrical parameters of the instrument through counting and energy spectrum measurement of reference samples;
6. The instrument has a standard serial communication RS-232C interface, and content data, counting data, and calibration data can all be uploaded to the computer;
7. Using disposable single-sided Mylar film sample cups can avoid cross contamination; The sample cup is made using multifunctional pressing parts, which are fast and convenient. The cup cover has air holes and can record the sample number S%(m/m)、 Date;
8. The sample loading platform is placed on the slide rail platform, with very precise positioning;
9. The instrument has a large data storage capacity, and the content analysis results and calibration curve parameters can be checked at any time;
10. The oil leakage is tightly protected, and the sample cup is placed on the leak proof component. It is only moved to the measurement position during sample analysis;
11. Safe X-ray protection measures: There are strict protective measures around the detection system of the instrument to prevent X-ray leakage, and there is no X-ray ionizing radiation harm to individuals and groups.
1.4 Specification
1. Sulfur measurement range: 0.005% to 5%;
2. Repeatability (r):<0.02894 (S+0.1691);
Typical value: Sample with 1% sulfur content, measurement time of 90 seconds, repeated 3 times, r≤0.02%
3. Reproducibility (R):<0.1215 (S+0.05555);
Typical value: Sample with 1% sulfur content, measurement time of 90 seconds, repeated 3 times, R≤0.05%
4. Detection limit: 10ppm;
5. Oil quantity: 3ml to 5ml; Powder sample: 3 grams
6. Measurement time: 30, 60, 90, 120, 150 seconds, set arbitrarily;
7. Single sample automatic measurement, providing the average value and standard deviation at the end of the measurement;
8. Number of calibration curves: The instrument can access 10 calibration curves;
9. Working conditions: Temperature range of 10-30 ℃; Relative humidity: ≤ 85%(30℃);
10. Power supply: AC220V ± 20V, 50Hz/60hz, rated power: 50W;
11. Size and weight: length 460mm x width 260mm x height 260mm; 11kg;